BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

563 related articles for article (PubMed ID: 36701313)

  • 21. A colorimetric reverse transcription-loop mediated isothermal amplification (RT-LAMP) method for the rapid detection of SARS-CoV-2 in Thailand.
    Bhakdeenuan P; Bunchoo S; Klayut K; Srisungngam S; Suphan O; Kongthap I; Suphankong S; Phetsuksiri B; Uppapong B; Rudeeaneksin J
    Trop Biomed; 2024 Mar; 41(1):64-69. PubMed ID: 38852135
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A molecular test based on RT-LAMP for rapid, sensitive and inexpensive colorimetric detection of SARS-CoV-2 in clinical samples.
    Amaral C; Antunes W; Moe E; Duarte AG; Lima LMP; Santos C; Gomes IL; Afonso GS; Vieira R; Teles HSS; Reis MS; da Silva MAR; Henriques AM; Fevereiro M; Ventura MR; Serrano M; Pimentel C
    Sci Rep; 2021 Aug; 11(1):16430. PubMed ID: 34385527
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Detection of SARS-CoV-2 RNA using RT-LAMP and molecular beacons.
    Sherrill-Mix S; Hwang Y; Roche AM; Glascock A; Weiss SR; Li Y; Haddad L; Deraska P; Monahan C; Kromer A; Graham-Wooten J; Taylor LJ; Abella BS; Ganguly A; Collman RG; Van Duyne GD; Bushman FD
    Genome Biol; 2021 Jun; 22(1):169. PubMed ID: 34082799
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A point-of-care SARS-CoV-2 test based on reverse transcription loop-mediated isothermal amplification without RNA extraction with diagnostic performance same as RT-PCR.
    Odiwuor N; Xiong J; Ogolla F; Hong W; Li X; Khan FM; Wang N; Yu J; Wei H
    Anal Chim Acta; 2022 Apr; 1200():339590. PubMed ID: 35256137
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Extraction-free RT-LAMP to detect SARS-CoV-2 is less sensitive but highly specific compared to standard RT-PCR in 101 samples.
    Schellenberg JJ; Ormond M; Keynan Y
    J Clin Virol; 2021 Mar; 136():104764. PubMed ID: 33636553
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Reverse Transcription Loop-Mediated Isothermal Amplification Assay for Ultrasensitive Detection of SARS-CoV-2 in Saliva and Viral Transport Medium Clinical Samples.
    Ganguli A; Mostafa A; Berger J; Lim J; Araud E; Baek J; Stewart de Ramirez SA; Baltaji A; Roth K; Aamir M; Aedma S; Mady M; Mahajan P; Sathe S; Johnson M; White K; Kumar J; Valera E; Bashir R
    Anal Chem; 2021 Jun; 93(22):7797-7807. PubMed ID: 34033472
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Development of a multiplex Loop-Mediated Isothermal Amplification (LAMP) assay for on-site diagnosis of SARS CoV-2.
    Jang WS; Lim DH; Yoon J; Kim A; Lim M; Nam J; Yanagihara R; Ryu SW; Jung BK; Ryoo NH; Lim CS
    PLoS One; 2021; 16(3):e0248042. PubMed ID: 33657176
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A high throughput immuno-affinity mass spectrometry method for detection and quantitation of SARS-CoV-2 nucleoprotein in human saliva and its comparison with RT-PCR, RT-LAMP, and lateral flow rapid antigen test.
    Lane D; Allsopp R; Holmes CW; Slingsby OC; Jukes-Jones R; Bird P; Anderson NL; Razavi M; Yip R; Pearson TW; Pope M; Khunti K; Doykov I; Hällqvist J; Mills K; Skipp P; Carling R; Ng L; Shaw J; Gupta P; Jones DJL
    Clin Chem Lab Med; 2024 May; 62(6):1206-1216. PubMed ID: 38253336
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Accessible LAMP-Enabled Rapid Test (ALERT) for Detecting SARS-CoV-2.
    Bektaş A; Covington MF; Aidelberg G; Arce A; Matute T; Núñez I; Walsh J; Boutboul D; Delaugerre C; Lindner AB; Federici F; Jayaprakash AD
    Viruses; 2021 Apr; 13(5):. PubMed ID: 33922716
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Detection of SARS-CoV-2 and the L452R spike mutation using reverse transcription loop-mediated isothermal amplification plus bioluminescent assay in real-time (RT-LAMP-BART).
    Iijima T; Ando S; Kanamori D; Kuroda K; Nomura T; Tisi L; Kilgore PE; Percy N; Kohase H; Hayakawa S; Seki M; Hoshino T
    PLoS One; 2022; 17(3):e0265748. PubMed ID: 35312732
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of COVID-19 laboratory diagnosis by commercial kits: Effectivity of RT-PCR to the RT-LAMP.
    Artik Y; Coşğun AB; Cesur NP; Hızel N; Uyar Y; Sur H; Ayan A
    J Med Virol; 2022 May; 94(5):1998-2007. PubMed ID: 34997587
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Loop mediated isothermal amplification (LAMP) assays as a rapid diagnostic for COVID-19.
    Kashir J; Yaqinuddin A
    Med Hypotheses; 2020 Aug; 141():109786. PubMed ID: 32361529
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Rapid point-of-care detection of SARS-CoV-2 using reverse transcription loop-mediated isothermal amplification (RT-LAMP).
    Mautner L; Baillie CK; Herold HM; Volkwein W; Guertler P; Eberle U; Ackermann N; Sing A; Pavlovic M; Goerlich O; Busch U; Wassill L; Huber I; Baiker A
    Virol J; 2020 Oct; 17(1):160. PubMed ID: 33087160
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Developing RT-LAMP assays for rapid diagnosis of SARS-CoV-2 in saliva.
    Huang X; Tang G; Ismail N; Wang X
    EBioMedicine; 2022 Jan; 75():103736. PubMed ID: 34922321
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Applicability of a colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for SARS-CoV-2 detection in high exposure risk setting.
    Nuchnoi P; Piromtong P; Siribal S; Anansilp K; Thichanpiang P; Okada PA
    Int J Infect Dis; 2023 Mar; 128():285-289. PubMed ID: 36642206
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Development of a reverse transcription loop-mediated isothermal amplification assay with novel quantitative pH biosensor readout method for SARS-CoV-2 detection.
    Astari DE; Massi MN; Masadah R; Hardjo M; Natzir R; Erlichster M; Chana G; Skafidas E; Seraj ZI; Elias SM; Soraya GV
    APMIS; 2024 Jul; 132(7):499-506. PubMed ID: 38659394
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comparison of RT-PCR, RT-LAMP, and Antigen Quantification Assays for the Detection of SARS-CoV-2.
    Tanimoto Y; Mori A; Miyamoto S; Ito E; Arikawa K; Iwamoto T
    Jpn J Infect Dis; 2022 May; 75(3):249-253. PubMed ID: 34588370
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Development and clinical application of loop-mediated isothermal amplification combined with lateral flow assay for rapid diagnosis of SARS-CoV-2.
    Tang J; Zhu J; Wang J; Qian H; Liu Z; Wang R; Cai Q; Fang Y; Huang W
    BMC Infect Dis; 2024 Jan; 24(1):81. PubMed ID: 38225546
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Accuracy of a raw saliva-based COVID-19 RT-LAMP diagnostic assay.
    Cabral KMDS; Baptista RCG; Castineiras TMPP; Tanuri A; Carneiro FA; Almeida MDS; Montero-Lomeli M
    Braz J Infect Dis; 2023; 27(4):102790. PubMed ID: 37478898
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Development and comparison of novel multiple cross displacement amplification (MCDA) assays with other nucleic acid amplification methods for SARS-CoV-2 detection.
    Luu LDW; Payne M; Zhang X; Luo L; Lan R
    Sci Rep; 2021 Jan; 11(1):1873. PubMed ID: 33479389
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 29.