These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 36706920)

  • 1. Characterization of ion release from a novel biomaterial, Molybdenum-47.5Rhenium, in physiologic environments.
    Mok JM; Poelstra K; Ammar K; McGirt M; Cormier J; Hart R; Bauman J; Cowart P; Sheth I; Singh P; Yadav J
    Spine J; 2023 Jun; 23(6):900-911. PubMed ID: 36706920
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of metal ions released from different dental implant-abutment couples on osteoblast function and secretion of bone resorbing mediators.
    Alrabeah GO; Brett P; Knowles JC; Petridis H
    J Dent; 2017 Nov; 66():91-101. PubMed ID: 28800964
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Patch test reactivity to a cobalt-chromium-molybdenum alloy and stainless steel in metal-allergic patients in correlation to the metal ion release.
    Summer B; Fink U; Zeller R; Rueff F; Maier S; Roider G; Thomas P
    Contact Dermatitis; 2007 Jul; 57(1):35-9. PubMed ID: 17577355
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evidence for the dissolution of molybdenum during tribocorrosion of CoCrMo hip implants in the presence of serum protein.
    Simoes TA; Bryant MG; Brown AP; Milne SJ; Ryan M; Neville A; Brydson R
    Acta Biomater; 2016 Nov; 45():410-418. PubMed ID: 27581397
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of alloying elements on cellular response and in-vitro corrosion behavior of titanium-molybdenum-chromium alloys for implant materials.
    Mat-Baharin NH; Razali M; Mohd-Said S; Syarif J; Muchtar A
    J Prosthodont Res; 2020 Oct; 64(4):490-497. PubMed ID: 32063537
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effect of platform switching on the levels of metal ion release from different implant-abutment couples.
    Alrabeah GO; Knowles JC; Petridis H
    Int J Oral Sci; 2016 Jun; 8(2):117-25. PubMed ID: 27357323
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Corrosion of dental magnet attachments for removable prostheses on teeth and implants.
    Boeckler AF; Ehring C; Morton D; Geis-Gerstorfer J; Setz JM
    J Prosthodont; 2009 Jun; 18(4):301-8. PubMed ID: 19210309
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In Vitro Corrosion Assessment of the Essure® Medical Device in Saline, Simulated Inflammatory Solution and Neutral Buffered Formalin.
    Aslan C; Gilbert JL
    Acta Biomater; 2022 Jul; 147():414-426. PubMed ID: 35598877
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Corrosion, ion release, and surface hardness of Ti-6Al-4V and cobalt-chromium alloys produced by CAD-CAM milling and laser sintering.
    Şahin M; Ünalan F; Mutlu İ
    J Prosthet Dent; 2022 Sep; 128(3):529.e1-529.e10. PubMed ID: 35934573
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Wear in total knee arthroplasty--just a question of polyethylene?: Metal ion release in total knee arthroplasty.
    Kretzer JP; Reinders J; Sonntag R; Hagmann S; Streit M; Jeager S; Moradi B
    Int Orthop; 2014 Feb; 38(2):335-40. PubMed ID: 24218115
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Three cases of metallosis associated with spine instrumentation.
    Ayers R; Miller M; Schowinsky J; Burger E; Patel V; Kleck C
    J Mater Sci Mater Med; 2017 Dec; 29(1):3. PubMed ID: 29196871
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Occupational exposure to nickel, cobalt, and chromium in the Lithuanian hard metal industry.
    Linauskiene K; Dahlin J; Ezerinskis Z; Isaksson M; Sapolaite J; Malinauskiene L
    Contact Dermatitis; 2021 Apr; 84(4):247-253. PubMed ID: 33277692
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of metal ion release from Ti6Al4V and Co-Cr-Mo casting alloys: in vivo and in vitro study.
    El Sawy AA; Shaarawy MA
    J Prosthodont; 2014 Feb; 23(2):89-97. PubMed ID: 23755902
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study.
    Jacobs JJ; Skipor AK; Patterson LM; Hallab NJ; Paprosky WG; Black J; Galante JO
    J Bone Joint Surg Am; 1998 Oct; 80(10):1447-58. PubMed ID: 9801213
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Retrieval analysis of the Essure® micro insert female sterilization implant: Methods for metal ion and microscopic analysis.
    Goodwin C; Aslan C; Gilbert JL
    Acta Biomater; 2023 May; 162():312-323. PubMed ID: 36963594
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Metal levels in cemented total hip arthroplasty. A comparison of well-fixed and loose implants.
    Brien WW; Salvati EA; Betts F; Bullough P; Wright T; Rimnac C; Buly R; Garvin K
    Clin Orthop Relat Res; 1992 Mar; (276):66-74. PubMed ID: 1537176
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomaterial optimization in total disc arthroplasty.
    Hallab N; Link HD; McAfee PC
    Spine (Phila Pa 1976); 2003 Oct; 28(20):S139-52. PubMed ID: 14560185
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Trunnion Failure of the Recalled Low Friction Ion Treatment Cobalt Chromium Alloy Femoral Head.
    Urish KL; Hamlin BR; Plakseychuk AY; Levison TJ; Higgs GB; Kurtz SM; DiGioia AM
    J Arthroplasty; 2017 Sep; 32(9):2857-2863. PubMed ID: 28478184
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reduction of Tribocorrosion Products When Using the Platform-Switching Concept.
    Alrabeah GO; Knowles JC; Petridis H
    J Dent Res; 2018 Aug; 97(9):995-1002. PubMed ID: 29578825
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cobalt-chromium alloys in dentistry: An evaluation of metal ion release.
    Lucchetti MC; Fratto G; Valeriani F; De Vittori E; Giampaoli S; Papetti P; Romano Spica V; Manzon L
    J Prosthet Dent; 2015 Oct; 114(4):602-8. PubMed ID: 25979449
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.