  • 1. A simple radiation beam position monitor.
    Vojnovic B; Sehmi DS; Newman RG
    Phys Med Biol; 1987 Sep; 32(9):1179-85. PubMed ID: 3671503
    [No Abstract]   [Full Text] [Related]  

  • 2. Beam position and energy monitoring in compact linear accelerators for radiotherapy.
    Ruf M; Müller S; Setzer S; Schmidt LP
    IEEE Trans Biomed Eng; 2014 Feb; 61(2):381-7. PubMed ID: 23996534
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement of beam current and evaluation of scatter production in an 18-MeV accelerator.
    Watts DL; Ibbott GS
    Med Phys; 1987; 14(4):662-4. PubMed ID: 3627007
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An improved optical backpointer for isocentric radiotherapy machines.
    Aldrich JE
    Med Phys; 1984; 11(4):559-60. PubMed ID: 6482851
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Improving precision and safety in the use of beam modifying devices in radiation therapy.
    Miller RW; van de Geijn J; Fraass BA
    Med Phys; 1990; 17(5):929-30. PubMed ID: 2233582
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Wedge filter for fast neutron beam from NIRS cyclotron].
    Kutsutani-Nakamura Y; Furukawa S; Iinuma T; Tsunemoto H; Kawashima K; Hoshino K; Hiraoka T; Maruyama T
    Nihon Igaku Hoshasen Gakkai Zasshi; 1983 May; 43(5):691-9. PubMed ID: 6622248
    [No Abstract]   [Full Text] [Related]  

  • 7. Radiation protection at medical accelerators.
    Agosteo S
    Radiat Prot Dosimetry; 2001; 96(4):393-406. PubMed ID: 11843088
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Low monitor units: significance in special therapy.
    Das IJ; Cheng CW; Akber SF
    Phys Med Biol; 1999 Feb; 44(2):L1-2. PubMed ID: 10070807
    [No Abstract]   [Full Text] [Related]  

  • 9. Single-beam radiotherapy knife. A practical theoretical model.
    Heifetz MD; Wexler M; Thompson R
    J Neurosurg; 1984 Apr; 60(4):814-8. PubMed ID: 6707750
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Characteristics of the photon beam from a new 25-MV linear accelerator.
    Aldrich JE; Andrew JW; Michaels HB; O'Brien PF
    Med Phys; 1985; 12(5):619-24. PubMed ID: 4046997
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An improved technique for aligning the light field with the radiation fields on radiotherapy accelerators.
    Johnsen SW; Hamm RW
    Med Phys; 1988; 15(2):267-8. PubMed ID: 3386602
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Monte Carlo modelling of electron beams from medical accelerators.
    Ma CM; Jiang SB
    Phys Med Biol; 1999 Dec; 44(12):R157-89. PubMed ID: 10616140
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A consistency monitor for radiation therapy treatments.
    Paliwal BR; Zaini M; McNutt T; Fairbanks EJ; Kitchen R
    Med Phys; 1996 Oct; 23(10):1805-7. PubMed ID: 8946377
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Properties of the 18-MV photon beam from a dual energy linear accelerator.
    Johnson DA; Ikoro NC; Chang CH; Scarbrough EC; Antich PP
    Med Phys; 1987; 14(6):1071-8. PubMed ID: 3696074
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Beam alignment tests for therapy accelerators.
    Lutz WR; Larsen RD; Bjärngard BE
    Int J Radiat Oncol Biol Phys; 1981 Dec; 7(12):1727-31. PubMed ID: 7333916
    [No Abstract]   [Full Text] [Related]  

  • 16. Design for a multiple target system for a medical cyclotron.
    Lee R; Dahl JR; Bigler RE; Laughlin JS
    Med Phys; 1981; 8(5):703-5. PubMed ID: 7290022
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of the Therac 6 linear accelerator for radiation therapy.
    Grant W; Ames J; Almond PR
    Med Phys; 1978; 5(5):448-9. PubMed ID: 101762
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Comparison of acceptance tests of 5 linear electron accelerators for radiotherapy].
    Scielzo G; Ciocca M; Zonca G; Maggi S; Ascione B; Grillo Ruggieri F; Valdagni R; Sverzellati PE; Spiga G; Miolo L
    Radiol Med; 1992 Jun; 83(6):804-9. PubMed ID: 1502363
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of air photoactivation at linear accelerators for radiotherapy.
    Tana L; Ciolini R; Ciuffardi E; Romei C; d'Errico F
    J Radiol Prot; 2015 Jun; 35(2):239-48. PubMed ID: 25760952
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [A device for the depth-dose distribution measurement of a medical proton beam in radiotherapy].
    Agapov AV; Mitsyn GV; Shvidkiĭ ; Shipulin KN
    Med Tekh; 2013; (5):28-31. PubMed ID: 24364168
    [No Abstract]   [Full Text] [Related]  