BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 36718592)

  • 1. Design and performance evaluation of a slit-slat camera for 2D prompt gamma imaging in proton therapy monitoring: A Monte Carlo simulation study.
    Malekzadeh E; Rajabi H; Tajik-Mansoury MA; Sabouri P; Fiorina E; Kalantari F
    Med Phys; 2023 Jun; 50(6):3701-3718. PubMed ID: 36718592
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Prompt gamma imaging with a slit camera for real-time range control in proton therapy.
    Smeets J; Roellinghoff F; Prieels D; Stichelbaut F; Benilov A; Busca P; Fiorini C; Peloso R; Basilavecchia M; Frizzi T; Dehaes JC; Dubus A
    Phys Med Biol; 2012 Jun; 57(11):3371-405. PubMed ID: 22572603
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Imaging of prompt gamma rays emitted during delivery of clinical proton beams with a Compton camera: feasibility studies for range verification.
    Polf JC; Avery S; Mackin DS; Beddar S
    Phys Med Biol; 2015 Sep; 60(18):7085-99. PubMed ID: 26317610
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Prompt gamma imaging of proton pencil beams at clinical dose rate.
    Perali I; Celani A; Bombelli L; Fiorini C; Camera F; Clementel E; Henrotin S; Janssens G; Prieels D; Roellinghoff F; Smeets J; Stichelbaut F; Vander Stappen F
    Phys Med Biol; 2014 Oct; 59(19):5849-71. PubMed ID: 25207724
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Detecting prompt gamma emission during proton therapy: the effects of detector size and distance from the patient.
    Polf JC; Mackin D; Lee E; Avery S; Beddar S
    Phys Med Biol; 2014 May; 59(9):2325-40. PubMed ID: 24732052
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A feasibility study of enhanced prompt gamma imaging for range verification in proton therapy using deep learning.
    Jiang Z; Polf JC; Barajas CA; Gobbert MK; Ren L
    Phys Med Biol; 2023 Mar; 68(7):. PubMed ID: 36848674
    [No Abstract]   [Full Text] [Related]  

  • 7. Distal edge determination precision for a multi-slat prompt-gamma camera: A comprehensive simulation and optimization of the detection system.
    Morozov A; Simões H; Crespo P
    Phys Med; 2021 Apr; 84():85-100. PubMed ID: 33882445
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Machine learning approach for proton range verification using real-time prompt gamma imaging with Compton cameras: addressing the total deposited energy information gap.
    Kazemi Kozani M
    Phys Med Biol; 2024 Mar; 69(7):. PubMed ID: 38417182
    [No Abstract]   [Full Text] [Related]  

  • 9. Influence of sub-nanosecond time of flight resolution for online range verification in proton therapy using the line-cone reconstruction in Compton imaging.
    Livingstone J; Dauvergne D; Etxebeste A; Fontana M; Gallin-Martel ML; Huisman B; Létang JM; Marcatili S; Sarrut D; Testa É
    Phys Med Biol; 2021 Jun; 66(12):. PubMed ID: 34020434
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A triple-imaging-modality system for simultaneous measurements of prompt gamma photons, prompt x-rays, and induced positrons during proton beam irradiation.
    Yamamoto S; Watabe H; Nakanishi K; Yabe T; Yamaguchi M; Kawachi N; Kamada K; Yoshikawa A; Miyake M; Tanaka KS; Kataoka J
    Phys Med Biol; 2024 Feb; 69(5):. PubMed ID: 38385258
    [No Abstract]   [Full Text] [Related]  

  • 11. Analytical modeling and Monte Carlo simulations of multi-parallel slit and knife-edge slit prompt gamma cameras.
    Huisman BFB; Muñoz E; Dauvergne D; Létang JM; Sarrut D; Testa É
    Phys Med Biol; 2023 May; 68(11):. PubMed ID: 37137315
    [No Abstract]   [Full Text] [Related]  

  • 12. Time-resolved imaging of prompt-gamma rays for proton range verification using a knife-edge slit camera based on digital photon counters.
    Cambraia Lopes P; Clementel E; Crespo P; Henrotin S; Huizenga J; Janssens G; Parodi K; Prieels D; Roellinghoff F; Smeets J; Stichelbaut F; Schaart DR
    Phys Med Biol; 2015 Aug; 60(15):6063-85. PubMed ID: 26216269
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of reconstructed prompt gamma emissions using maximum likelihood estimation and origin ensemble algorithms for a Compton camera system tailored to proton range monitoring.
    Valencia Lozano I; Dedes G; Peterson S; Mackin D; Zoglauer A; Beddar S; Avery S; Polf J; Parodi K
    Z Med Phys; 2023 May; 33(2):124-134. PubMed ID: 35750591
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields.
    Padilla-Cabal F; Alejandro Fragoso J; Franz Resch A; Georg D; Fuchs H
    Med Phys; 2020 Jan; 47(1):223-233. PubMed ID: 31661559
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Technical Note: Experimental verification of magnetic field-induced beam deflection and Bragg peak displacement for MR-integrated proton therapy.
    Schellhammer SM; Gantz S; Lühr A; Oborn BM; Bussmann M; Hoffmann AL
    Med Phys; 2018 Jul; 45(7):3429-3434. PubMed ID: 29763970
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A reconstruction approach for proton computed tomography by modeling the integral depth dose of the scanning proton pencil beam.
    Chen X; Medrano M; Sun B; Hao Y; Reynoso FJ; Darafsheh A; Yang D; Zhang T; Zhao T
    Med Phys; 2022 Apr; 49(4):2602-2620. PubMed ID: 35103331
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simulation of proton range monitoring in an anthropomorphic phantom using multi-slat collimators and time-of-flight detection of prompt-gamma quanta.
    Cambraia Lopes P; Crespo P; Simões H; Ferreira Marques R; Parodi K; Schaart DR
    Phys Med; 2018 Oct; 54():1-14. PubMed ID: 30336998
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accounting for prompt gamma emission and detection for range verification in proton therapy treatment planning.
    Tian L; Huang Z; Janssens G; Landry G; Dedes G; Kamp F; Belka C; Pinto M; Parodi K
    Phys Med Biol; 2021 Feb; 66(5):055005. PubMed ID: 33171445
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development and validation of the Dynamic Collimation Monte Carlo simulation package for pencil beam scanning proton therapy.
    Nelson NP; Culberson WS; Hyer DE; Geoghegan TJ; Patwardhan KA; Smith BR; Flynn RT; Yu J; Rana S; Gutiérrez AN; Hill PM
    Med Phys; 2021 Jun; 48(6):3172-3185. PubMed ID: 33740253
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ionoacoustic application of an optical hydrophone to detect proton beam range in water.
    Sueyasu S; Takayanagi T; Miyazaki K; Kuriyama Y; Ishi Y; Uesugi T; Unlu MB; Kudo N; Chen Y; Kasamatsu K; Fujii M; Kobayashi M; Rohringer W; Matsuura T
    Med Phys; 2023 Apr; 50(4):2438-2449. PubMed ID: 36565440
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.