BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 36722019)

  • 1. Variability in oxygen delivery with bag-valve-mask devices: An observational laboratory simulation study.
    Dodds JM; Appelqvist DI; Paleologos MS; Downey RG
    Anaesth Intensive Care; 2023 Mar; 51(2):130-140. PubMed ID: 36722019
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Can EMS Providers Provide Appropriate Tidal Volumes in a Simulated Adult-sized Patient with a Pediatric-sized Bag-Valve-Mask?
    Siegler J; Kroll M; Wojcik S; Moy HP
    Prehosp Emerg Care; 2017; 21(1):74-78. PubMed ID: 27690714
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Large variations of oxygen delivery in self-inflating resuscitation bags used for preoxygenation - a mechanical simulation.
    Grauman S; Johansson J; Drevhammar T
    Scand J Trauma Resusc Emerg Med; 2021 Jul; 29(1):98. PubMed ID: 34281616
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In-vitro comparison of bag-valve-mask and the manually triggered oxygen-powered breathing device.
    Menegazzi JJ; Winslow HJ
    Acad Emerg Med; 1994; 1(1):29-33. PubMed ID: 7621149
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A prospective, randomised trial of pre-oxygenation strategies available in the pre-hospital environment.
    Groombridge CJ; Ley E; Miller M; Konig T
    Anaesthesia; 2017 May; 72(5):580-584. PubMed ID: 28295147
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A strategy to optimise the performance of the mouth-to-bag resuscitator using small tidal volumes: effects on lung and gastric ventilation in a bench model of an unprotected airway.
    Zecha-Stallinger A; Wenzel V; Wagner-Berger HG; von Goedecke A; Lindner KH; Hörmann C
    Resuscitation; 2004 Apr; 61(1):69-74. PubMed ID: 15081184
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Experimental validation of a portable tidal volume indicator for bag valve mask ventilation.
    Maxey BS; White LA; Solitro GF; Conrad SA; Alexander JS
    BMC Biomed Eng; 2022 Nov; 4(1):9. PubMed ID: 36384855
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the self-inflating bag-valve-mask and non-rebreather mask as preoxygenation devices in volunteers.
    Robinson A; Ercole A
    BMJ Open; 2012; 2(5):. PubMed ID: 23103607
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of different airway management strategies to ventilate apneic, nonpreoxygenated patients.
    Dörges V; Wenzel V; Knacke P; Gerlach K
    Crit Care Med; 2003 Mar; 31(3):800-4. PubMed ID: 12626987
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Can Altering Grip Technique and Bag Size Optimize Volume Delivered with Bag-Valve-Mask by Emergency Medical Service Providers?
    Kroll M; Das J; Siegler J
    Prehosp Emerg Care; 2019; 23(2):210-214. PubMed ID: 30130437
    [TBL] [Abstract][Full Text] [Related]  

  • 11. It's In The Bag: Tidal Volumes in Adult and Pediatric Bag Valve Masks.
    Dafilou B; Schwester D; Ruhl N; Marques-Baptista A
    West J Emerg Med; 2020 Apr; 21(3):722-726. PubMed ID: 32421525
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Smaller tidal volumes with room-air are not sufficient to ensure adequate oxygenation during bag-valve-mask ventilation.
    Dörges V; Ocker H; Hagelberg S; Wenzel V; Idris AH; Schmucker P
    Resuscitation; 2000 Mar; 44(1):37-41. PubMed ID: 10699698
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Decreasing peak flow rate with a new bag-valve-mask device: effects on respiratory mechanics, and gas distribution in a bench model of an unprotected airway.
    Wagner-Berger HG; Wenzel V; Stallinger A; Voelckel WG; Rheinberger K; Stadlbauer KH; Augenstein S; Dörges V; Lindner KH; Hörmann C
    Resuscitation; 2003 May; 57(2):193-9. PubMed ID: 12745188
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Single Rescuer Ventilation Using a Bag Valve Mask with Removable External Handle: A Randomized Crossover Trial.
    Reed P; Zobrist B; Casmaer M; Schauer SG; Kester N; April MD
    Prehosp Disaster Med; 2017 Dec; 32(6):625-630. PubMed ID: 28807071
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of Ventilation Using Adult and Pediatric Manual Resuscitators in a Simulated Adult Patient.
    Justice JM; Slutsky AS; Stanford N; Isennock C; Siddiqui S; Zamir H; Walker JR; Brady MF
    Respir Care; 2024 Apr; ():. PubMed ID: 38688544
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Use of a novel pedal-operated compressor is non-inferior to the use of a standard hand-compressed bag-valve mask.
    Sojar SH; Neronha ZJ; Vuong B; Puzone JR; Decerbo PC; Baird J; Wing R
    J Am Coll Emerg Physicians Open; 2022 Feb; 3(1):e12668. PubMed ID: 35156091
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Smaller tidal volumes during cardiopulmonary resuscitation: comparison of adult and paediatric self-inflatable bags with three different ventilatory devices.
    Doerges V; Sauer C; Ocker H; Wenzel V; Schmucker P
    Resuscitation; 1999 Dec; 43(1):31-7. PubMed ID: 10636315
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Assessment of Common Preoxygenation Strategies Outside of the Operating Room Environment.
    Groombridge C; Chin CW; Hanrahan B; Holdgate A
    Acad Emerg Med; 2016 Mar; 23(3):342-6. PubMed ID: 26728311
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development and Evaluation of an Automated Manual Resuscitator-Based Emergency Ventilator-Alternative.
    Urbina J; Monks SM; Ochoa L; Stump RF; Wicker RB; Danek C; Torres VI; Crawford SB
    Cureus; 2021 Mar; 13(3):e13642. PubMed ID: 33824795
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of manual and automatic manually triggered ventilation performance and ergonomics using a simulation model.
    Marjanovic N; Le Floch S; Jaffrelot M; L'Her E
    Respir Care; 2014 May; 59(5):735-42. PubMed ID: 24170912
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.