These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 36729962)

  • 41. Development of a flexible inflow cannula with titanium inflow tip for the NEDO biventricular assist device.
    Watanabe K; Asai T; Ichikawa S; Motomura T; Hata A; Ito S; Shinohara T; Tsujimura S; Oestmann DJ; Nosé Y
    ASAIO J; 2004; 50(4):381-6. PubMed ID: 15307553
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Preclinical Evaluation of the EVAHEART 2 Centrifugal Left Ventricular Assist Device in Bovines.
    Motomura T; Tuzun E; Yamazaki K; Tatsumi E; Benkowski R; Yamazaki S
    ASAIO J; 2019; 65(8):845-854. PubMed ID: 30134258
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Inflow cannula position as risk factor for stroke in patients with HeartMate 3 left ventricular assist devices.
    Schlöglhofer T; Aigner P; Migas M; Beitzke D; Dimitrov K; Wittmann F; Riebandt J; Granegger M; Wiedemann D; Laufer G; Moscato F; Schima H; Zimpfer D
    Artif Organs; 2022 Jun; 46(6):1149-1157. PubMed ID: 34978722
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Quantitative Assessment of Inflow Malposition in Two Continuous-Flow Left Ventricular Assist Devices.
    Sorensen EN; Kon ZN; Feller ED; Pham SM; Griffith BP
    Ann Thorac Surg; 2018 May; 105(5):1377-1383. PubMed ID: 29305851
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Left ventricular assist device inflow cannula thrombus: characterization with two-dimensional transthoracic echocardiography.
    Missov E
    ASAIO J; 2013; 59(6):662-3. PubMed ID: 24172272
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Surgical technique influences HeartMate II left ventricular assist device thrombosis.
    Taghavi S; Ward C; Jayarajan SN; Gaughan J; Wilson LM; Mangi AA
    Ann Thorac Surg; 2013 Oct; 96(4):1259-1265. PubMed ID: 23968757
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Role of contrast CT for the diagnosis and the prognosis of suspected LVAD thrombosis.
    Tran BC; Nijjar PS
    J Card Surg; 2017 Feb; 32(2):162-165. PubMed ID: 28088844
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Novel Formula to Calculate Three-Dimensional Angle Between Inflow Cannula and Device Body of HeartMate II LVAD.
    Tsushima Y; Imamura T; Landeras L; Kitahara H; Gonoi W; Sayer G; Uriel N; Jeevanandam V; Ota T
    Ann Thorac Surg; 2020 Jan; 109(1):63-68. PubMed ID: 31255615
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Misplacement of LVAD inflow cannula leads to insufficient output and tissue hypoperfusion.
    Crumpstone T; Martin TD; Yang JJ; Peng YG
    J Artif Organs; 2010 Dec; 13(4):225-7. PubMed ID: 20859646
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Development of the DexAide right ventricular assist device inflow cannula.
    Ootaki Y; Saeed D; Ootaki C; Akiyama M; Fumoto H; Horai T; Dessoffy R; Catanese J; Massiello A; Horvath D; Chen JF; Benefit S; Golding LA; Fukamachi K
    ASAIO J; 2008; 54(1):31-6. PubMed ID: 18204313
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Hematologic markers better predict left ventricular assist device thrombosis than echocardiographic or pump parameters.
    Bartoli CR; Ghotra AS; Pachika AR; Birks EJ; McCants KC
    Thorac Cardiovasc Surg; 2014 Aug; 62(5):414-8. PubMed ID: 24995532
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Effect of Ventricular Arrhythmia Ablation in Patients With Heart Mate II Left Ventricular Assist Devices: An Evaluation of Ablation Therapy.
    Snipelisky D; Reddy YN; Manocha K; Patel A; Dunlay SM; Friedman PA; Munger TM; Asirvatham SJ; Packer DL; Cha YM; Kapa S; Brady PA; Noseworthy PA; Maleszewski JJ; Mulpuru SK
    J Cardiovasc Electrophysiol; 2017 Jan; 28(1):68-77. PubMed ID: 27766717
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Virtual Fitting and Hemodynamic Simulation of the EVAHEART 2 Left Ventricular Assist Device and Double-Cuff Tipless Inflow Cannula.
    Sonntag SJ; Lipinski E; Neidlin M; Hugenroth K; Benkowski R; Motomura T; Kaufmann TAS
    ASAIO J; 2019; 65(7):698-706. PubMed ID: 30134259
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Characterization of Ventricular Tachycardia After Left Ventricular Assist Device Implantation as Destination Therapy: A Single-Center Ablation Experience.
    Moss JD; Flatley EE; Beaser AD; Shin JH; Nayak HM; Upadhyay GA; Burke MC; Jeevanandam V; Uriel N; Tung R
    JACC Clin Electrophysiol; 2017 Dec; 3(12):1412-1424. PubMed ID: 29759673
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Novel percutaneous dual-lumen cannula-based right ventricular assist device provides effective support for refractory right ventricular failure after left ventricular assist device implantation.
    Salna M; Garan AR; Kirtane AJ; Karmpaliotis D; Green P; Takayama H; Sanchez J; Kurlansky P; Yuzefpolskaya M; Colombo PC; Naka Y; Takeda K
    Interact Cardiovasc Thorac Surg; 2020 Apr; 30(4):499-506. PubMed ID: 31986207
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Flow analysis of ventricular assist device inflow and outflow cannula positioning using a naturally shaped ventricle and aortic branch.
    Laumen M; Kaufmann T; Timms D; Schlanstein P; Jansen S; Gregory S; Wong KC; Schmitz-Rode T; Steinseifer U
    Artif Organs; 2010 Oct; 34(10):798-806. PubMed ID: 20964698
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Screening for Outflow Cannula Malfunction of Left Ventricular Assist Devices (LVADs) With the Use of Doppler Echocardiography: New LVAD-Specific Reference Values for Contemporary Devices.
    Grinstein J; Kruse E; Collins K; Sayer G; Fedson S; Kim GH; Sarswat N; Adatya S; Ota T; Jeevanandam V; Mor-Avi V; Uriel N; Lang RM
    J Card Fail; 2016 Oct; 22(10):808-14. PubMed ID: 27288845
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Detection of acquired von Willebrand syndrome after ventricular assist device by total thrombus-formation analysis system.
    Takashio S; Kaikita K; Nishi M; Morioka M; Higo T; Shiose A; Doman T; Horiuchi H; Fukui T; Tsujita K
    ESC Heart Fail; 2020 Oct; 7(5):3235-3239. PubMed ID: 32700467
    [TBL] [Abstract][Full Text] [Related]  

  • 59. The axial continuous-flow blood pump: Bench evaluation of changes in flow associated with changes of inflow cannula angle.
    Karimov JH; Zhen-Yu Tong M; Byram N; Sunagawa G; Dessoffy R; Moazami N; Starling RC; Fukamachi K
    J Heart Lung Transplant; 2017 Jan; 36(1):106-112. PubMed ID: 28029574
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Left ventricular non-compaction cardiomyopathy and left ventricular assist device: a word of caution.
    Kornberger A; Stock UA; Risteski P; Beiras Fernandez A
    J Cardiothorac Surg; 2016 Jul; 11(1):108. PubMed ID: 27422642
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.