These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 36731864)

  • 21. Cleaning potential of different air abrasive powders and their impact on implant surface roughness.
    Matsubara VH; Leong BW; Leong MJL; Lawrence Z; Becker T; Quaranta A
    Clin Implant Dent Relat Res; 2020 Feb; 22(1):96-104. PubMed ID: 31837107
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The effect of different cleaning methods on the surface and temperature of failed titanium implants: an in vitro study.
    Hakki SS; Tatar G; Dundar N; Demiralp B
    Lasers Med Sci; 2017 Apr; 32(3):563-571. PubMed ID: 28160204
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The Effect of Microcosm Biofilm Decontamination on Surface Topography, Chemistry, and Biocompatibility Dynamics of Implant Titanium Surfaces.
    Sousa V; Mardas N; Spratt D; Hassan IA; Walters NJ; Beltrán V; Donos N
    Int J Mol Sci; 2022 Sep; 23(17):. PubMed ID: 36077428
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Surgical Treatment of Severe Peri-Implantitis Using a Round Titanium Brush for Implant Surface Decontamination: A Case Report With Clinical Reentry.
    An YZ; Lee JH; Heo YK; Lee JS; Jung UW; Choi SH
    J Oral Implantol; 2017 Jun; 43(3):218-225. PubMed ID: 28218864
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Non-surgical treatment of peri-implantitis with and without erythritol air-polishing a 12-month randomized controlled trial.
    Selimović A; Bunæs DF; Lie SA; Lobekk MA; Leknes KN
    BMC Oral Health; 2023 Apr; 23(1):240. PubMed ID: 37095488
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Artificial biofilm removal in a peri-implant mucositis model: Efficacy of air polishing technology as adjunct to ultrasonic debridement alone and impact of the site and the depth of mucosal tunnel-An in vitro study.
    Discepoli N; Mirra R; Vesentin C; Marruganti C; Ferrari M
    Clin Implant Dent Relat Res; 2022 Apr; 24(2):242-250. PubMed ID: 35324063
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Influence of eight debridement techniques on three different titanium surfaces: A laboratory study.
    Tran C; Khan A; Meredith N; Walsh LJ
    Int J Dent Hyg; 2023 Feb; 21(1):238-250. PubMed ID: 35943293
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Clinical, microbiological and biochemical impact of a supportive care protocol with an air-polishing device, after surgical treatment of peri-implantitis: Randomized clinical trial.
    Luengo F; Sanz-Esporrín J; Sanz-Sánchez I; Solonko M; Herrera D; Sanz M
    Clin Oral Implants Res; 2023 Apr; 34(4):378-392. PubMed ID: 36789504
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Antimicrobial efficiency and cytocompatibility of different decontamination methods on titanium and zirconium surfaces.
    Stein JM; Conrads G; Abdelbary MMH; Yekta-Michael SS; Buttler P; Glock J; Sadvandi G; Kaufmann R; Apel C
    Clin Oral Implants Res; 2023 Jan; 34(1):20-32. PubMed ID: 36259118
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Efficacy of combined application of glycine powder air-polishing in non-surgical treatment of peri-implant diseases].
    Sun F; Li SQ; Wei YP; Zhong JS; Wang C; Hu WJ
    Beijing Da Xue Xue Bao Yi Xue Ban; 2022 Feb; 54(1):119-125. PubMed ID: 35165478
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Impact of physical decontamination methods on zirconia implant surface and subsequent bacterial adhesion: An in-vitro study.
    Tan NCP; Miller CM; Antunes E; Sharma D
    Clin Exp Dent Res; 2022 Feb; 8(1):313-321. PubMed ID: 34599862
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Efficacy of mechanical/physical approaches for implant surface decontamination in non-surgical submarginal instrumentation of peri-implantitis. A systematic review.
    Cosgarea R; Roccuzzo A; Jepsen K; Sculean A; Jepsen S; Salvi GE
    J Clin Periodontol; 2023 Jun; 50 Suppl 26():188-211. PubMed ID: 36550060
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Evaluation of the three methods of bacterial decontamination on implants with three different surfaces.
    Kubasiewicz-Ross P; Fleischer M; Pitułaj A; Hadzik J; Nawrot-Hadzik I; Bortkiewicz O; Dominiak M; Jurczyszyn K
    Adv Clin Exp Med; 2020 Feb; 29(2):177-182. PubMed ID: 32097545
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effects of an amino acid buffered hypochlorite solution as an adjunctive to air-powder abrasion in open-flap surface decontamination of implants failed for peri-implantitis: an ex vivo randomized clinical trial.
    La Monaca G; Pranno N; Mengoni F; Puggioni G; Polimeni A; Annibali S; Cristalli MP
    Clin Oral Investig; 2023 Feb; 27(2):827-835. PubMed ID: 35802191
    [TBL] [Abstract][Full Text] [Related]  

  • 35. In-vitro assessment of the efficiency of cold atmospheric plasma on decontamination of titanium dental implants.
    Flörke C; Janning J; Hinrichs C; Behrens E; Liedtke KR; Sen S; Christofzik D; Wiltfang J; Gülses A
    Int J Implant Dent; 2022 Mar; 8(1):12. PubMed ID: 35275307
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Dental Implant Surface Decontamination and Surface Change of an Electrolytic Method versus Mechanical Approaches: A Pilot In Vitro Study.
    Assunção MA; Botelho J; Machado V; Proença L; Matos APA; Mendes JJ; Bessa LJ; Taveira N; Santos A
    J Clin Med; 2023 Feb; 12(4):. PubMed ID: 36836238
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Erythritol-Enriched Air-Polishing Powder for the Surgical Treatment of Peri-Implantitis.
    Taschieri S; Weinstein R; Del Fabbro M; Corbella S
    ScientificWorldJournal; 2015; 2015():802310. PubMed ID: 26065025
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of the effects of air-powder abrasion, chemical decontamination, or their combination in open-flap surface decontamination of implants failed for peri-implantitis: an ex vivo study.
    Pranno N; Cristalli MP; Mengoni F; Sauzullo I; Annibali S; Polimeni A; La Monaca G
    Clin Oral Investig; 2021 May; 25(5):2667-2676. PubMed ID: 32975703
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of decontamination methods of oral biofilms formed on screw-shaped, rough and machined surface implants: an ex vivo study.
    Otsuki M; Wada M; Yamaguchi M; Kawabata S; Maeda Y; Ikebe K
    Int J Implant Dent; 2020 Apr; 6(1):18. PubMed ID: 32318868
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The effect of five mechanical instrumentation protocols on implant surface topography and roughness: A scanning electron microscope and confocal laser scanning microscope analysis.
    Cha JK; Paeng K; Jung UW; Choi SH; Sanz M; Sanz-Martín I
    Clin Oral Implants Res; 2019 Jun; 30(6):578-587. PubMed ID: 31022305
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.