203 related articles for article (PubMed ID: 36735652)
1. Blood pressure monitoring during anesthesia induction using PPG morphology features and machine learning.
Aguet C; Jorge J; Van Zaen J; Proença M; Bonnier G; Frossard P; Lemay M
PLoS One; 2023; 18(2):e0279419. PubMed ID: 36735652
[TBL] [Abstract][Full Text] [Related]
2. Machine Learning Approaches For Improved Continuous, Non-occlusive Arterial Pressure Monitoring Using Photoplethysmography.
Jorge J; Proenca M; Aguet C; Van Zaen J; Bonnier G; Renevey P; Lemkaddem A; Schoettker P; Lemay M
Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():910-913. PubMed ID: 33018132
[TBL] [Abstract][Full Text] [Related]
3. Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches.
Khalid SG; Zhang J; Chen F; Zheng D
J Healthc Eng; 2018; 2018():1548647. PubMed ID: 30425819
[TBL] [Abstract][Full Text] [Related]
4. Blood pressure estimation and classification using a reference signal-less photoplethysmography signal: a deep learning framework.
Pankaj ; Kumar A; Komaragiri R; Kumar M
Phys Eng Sci Med; 2023 Dec; 46(4):1589-1605. PubMed ID: 37747644
[TBL] [Abstract][Full Text] [Related]
5. A novel method for continuous blood pressure estimation based on a single-channel photoplethysmogram signal.
Hu Q; Deng X; Wang A; Yang C
Physiol Meas; 2021 Jan; 41(12):125009. PubMed ID: 33166940
[TBL] [Abstract][Full Text] [Related]
6. Characters available in photoplethysmogram for blood pressure estimation: beyond the pulse transit time.
Li Y; Wang Z; Zhang L; Yang X; Song J
Australas Phys Eng Sci Med; 2014 Jun; 37(2):367-76. PubMed ID: 24722801
[TBL] [Abstract][Full Text] [Related]
7. BiGRU-attention for Continuous blood pressure trends estimation through single channel PPG.
Liu Z; Zhang Y; Zhou C
Comput Biol Med; 2024 Jan; 168():107795. PubMed ID: 38056206
[TBL] [Abstract][Full Text] [Related]
8. PPG-Based Blood Pressure Monitoring by Pulse Wave Analysis: Calibration Parameters are Stable for Three Months.
Proenca M; Bonnier G; Ferrario D; Verjus C; Lemay M
Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():5560-5563. PubMed ID: 31947115
[TBL] [Abstract][Full Text] [Related]
9. Features from the photoplethysmogram and the electrocardiogram for estimating changes in blood pressure.
Finnegan E; Davidson S; Harford M; Watkinson P; Tarassenko L; Villarroel M
Sci Rep; 2023 Jan; 13(1):986. PubMed ID: 36653426
[TBL] [Abstract][Full Text] [Related]
10. Schrödinger spectrum based continuous cuff-less blood pressure estimation using clinically relevant features from PPG signal and its second derivative.
Sarkar S; Ghosh A
Comput Biol Med; 2023 Nov; 166():107558. PubMed ID: 37806054
[TBL] [Abstract][Full Text] [Related]
11. KD-Informer: A Cuff-Less Continuous Blood Pressure Waveform Estimation Approach Based on Single Photoplethysmography.
Ma C; Zhang P; Song F; Sun Y; Fan G; Zhang T; Feng Y; Zhang G
IEEE J Biomed Health Inform; 2023 May; 27(5):2219-2230. PubMed ID: 35700247
[TBL] [Abstract][Full Text] [Related]
12. An Estimation Method of Continuous Non-Invasive Arterial Blood Pressure Waveform Using Photoplethysmography: A U-Net Architecture-Based Approach.
Athaya T; Choi S
Sensors (Basel); 2021 Mar; 21(5):. PubMed ID: 33800106
[TBL] [Abstract][Full Text] [Related]
13. A PPG-Based Calibration-Free Cuffless Blood Pressure Estimation Method Using Cardiovascular Dynamics.
Samimi H; Dajani HR
Sensors (Basel); 2023 Apr; 23(8):. PubMed ID: 37112490
[TBL] [Abstract][Full Text] [Related]
14. A deep learning method for continuous noninvasive blood pressure monitoring using photoplethysmography.
Liang H; He W; Xu Z
Physiol Meas; 2023 May; 44(5):. PubMed ID: 37116508
[No Abstract] [Full Text] [Related]
15. Estimating Blood Pressure from the Photoplethysmogram Signal and Demographic Features Using Machine Learning Techniques.
Chowdhury MH; Shuzan MNI; Chowdhury MEH; Mahbub ZB; Uddin MM; Khandakar A; Reaz MBI
Sensors (Basel); 2020 Jun; 20(11):. PubMed ID: 32492902
[TBL] [Abstract][Full Text] [Related]
16. Hybrid CNN-SVR Blood Pressure Estimation Model Using ECG and PPG Signals.
Rastegar S; Gholam Hosseini H; Lowe A
Sensors (Basel); 2023 Jan; 23(3):. PubMed ID: 36772300
[TBL] [Abstract][Full Text] [Related]
17. Calibration-free blood pressure estimation based on a convolutional neural network.
Cho J; Shin H; Choi A
Psychophysiology; 2024 Apr; 61(4):e14480. PubMed ID: 37971153
[TBL] [Abstract][Full Text] [Related]
18. Cuff-Less Blood Pressure Estimation From Photoplethysmography via Visibility Graph and Transfer Learning.
Wang W; Mohseni P; Kilgore KL; Najafizadeh L
IEEE J Biomed Health Inform; 2022 May; 26(5):2075-2085. PubMed ID: 34784289
[TBL] [Abstract][Full Text] [Related]
19. A continuous cuffless blood pressure measurement from optimal PPG characteristic features using machine learning algorithms.
Nishan A; M Taslim Uddin Raju S; Hossain MI; Dipto SA; M Tanvir Uddin S; Sijan A; Chowdhury MAS; Ahmad A; Mahamudul Hasan Khan M
Heliyon; 2024 Mar; 10(6):e27779. PubMed ID: 38533045
[TBL] [Abstract][Full Text] [Related]
20. New photoplethysmogram indicators for improving cuffless and continuous blood pressure estimation accuracy.
Lin WH; Wang H; Samuel OW; Liu G; Huang Z; Li G
Physiol Meas; 2018 Feb; 39(2):025005. PubMed ID: 29319536
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]