BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

213 related articles for article (PubMed ID: 36741832)

  • 1. Intra-individual comparison of coronary calcium scoring between photon counting detector- and energy integrating detector-CT: Effects on risk reclassification.
    Wolf EV; Halfmann MC; Schoepf UJ; Zsarnoczay E; Fink N; Griffith JP; Aquino GJ; Willemink MJ; O'Doherty J; Hell MM; Suranyi P; Kabakus IM; Baruah D; Varga-Szemes A; Emrich T
    Front Cardiovasc Med; 2022; 9():1053398. PubMed ID: 36741832
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Intra-individual comparison of coronary CT angiography-based FFR between energy-integrating and photon-counting detector CT systems.
    Zsarnoczay E; Pinos D; Schoepf UJ; Fink N; O'Doherty J; Gnasso C; Griffith J; Vecsey-Nagy M; Suranyi P; Maurovich-Horvat P; Emrich T; Varga-Szemes A
    Int J Cardiol; 2024 Mar; 399():131684. PubMed ID: 38151162
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Photon-Counting Detector Computed Tomography Versus Energy-Integrating Detector Computed Tomography for Coronary Artery Calcium Quantitation.
    McCollough CH; Winfree TN; Melka EF; Rajendran K; Carter RE; Leng S
    J Comput Assist Tomogr; 2024 Mar-Apr 01; 48(2):212-216. PubMed ID: 37801651
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Technical note: Exploring the detectability of coronary calcification using ultra-high-resolution photon-counting-detector CT.
    Chang S; Ren L; Tang S; Marsh JF; Hsieh S; McCollough CH; Leng S
    Med Phys; 2023 Nov; 50(11):6836-6843. PubMed ID: 37650788
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dose Reduction for Sinus and Temporal Bone Imaging Using Photon-Counting Detector CT With an Additional Tin Filter.
    Rajendran K; Voss BA; Zhou W; Tao S; DeLone DR; Lane JI; Weaver JM; Carlson ML; Fletcher JG; McCollough CH; Leng S
    Invest Radiol; 2020 Feb; 55(2):91-100. PubMed ID: 31770297
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of the Agatston score acquired with photon-counting detector CT and energy-integrating detector CT: ex vivo study of cadaveric hearts.
    Skoog S; Henriksson L; Gustafsson H; Sandstedt M; Elvelind S; Persson A
    Int J Cardiovasc Imaging; 2022 May; 38(5):1145-1155. PubMed ID: 34988781
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Photon-counting detector CT reduces the rate of referrals to invasive coronary angiography as compared to CT with whole heart coverage energy-integrating detector.
    Simon J; Hrenkó Á; Kerkovits NM; Nagy K; Vértes M; Balogh H; Nagy N; Munkácsi T; Emrich T; Varga-Szemes A; Boussoussou M; Vattay B; Vecsey-Nagy M; Kolossváry M; Szilveszter B; Merkely B; Maurovich-Horvat P
    J Cardiovasc Comput Tomogr; 2024; 18(1):69-74. PubMed ID: 38097408
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Coronary artery calcium scoring with photon-counting CT: first in vivo human experience.
    Symons R; Sandfort V; Mallek M; Ulzheimer S; Pourmorteza A
    Int J Cardiovasc Imaging; 2019 Apr; 35(4):733-739. PubMed ID: 30635819
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck: First In Vivo Human Results.
    Symons R; Reich DS; Bagheri M; Cork TE; Krauss B; Ulzheimer S; Kappler S; Bluemke DA; Pourmorteza A
    Invest Radiol; 2018 Mar; 53(3):135-142. PubMed ID: 28926370
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Low-contrast detectability of photon-counting-detector CT at different scan modes and image types in comparison with energy-integrating-detector CT.
    Fan M; Zhou Z; Wellinghoff J; McCollough CH; Yu L
    J Med Imaging (Bellingham); 2024 Dec; 11(Suppl 1):S12803. PubMed ID: 38799271
    [TBL] [Abstract][Full Text] [Related]  

  • 11.
    Marsh JF; VanMeter PD; Rajendran K; Leng S; McCollough CH
    J Med Imaging (Bellingham); 2023 Jul; 10(4):043501. PubMed ID: 37408984
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quantifying lumen diameter in coronary artery stents with high-resolution photon counting detector CT and convolutional neural network denoising.
    Koons EK; Thorne JE; Huber NR; Chang S; Rajendran K; McCollough CH; Leng S
    Med Phys; 2023 Jul; 50(7):4173-4181. PubMed ID: 37069830
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Improved coronary calcification quantification using photon-counting-detector CT: an ex vivo study in cadaveric specimens.
    Sandstedt M; Marsh J; Rajendran K; Gong H; Tao S; Persson A; Leng S; McCollough C
    Eur Radiol; 2021 Sep; 31(9):6621-6630. PubMed ID: 33713174
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Tube voltage-independent coronary calcium scoring on a first-generation dual-source photon-counting CT-a proof-of-principle phantom study.
    Mergen V; Higashigaito K; Allmendinger T; Manka R; Euler A; Alkadhi H; Eberhard M
    Int J Cardiovasc Imaging; 2022 Apr; 38(4):905-912. PubMed ID: 34780012
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reduced versus standard dose contrast volume for contrast-enhanced abdominal CT in overweight and obese patients using photon counting detector technology vs. second-generation dual-source energy integrating detector CT.
    Hagen F; Estler A; Hofmann J; Walder L; Faby S; Almarie B; Nikolaou K; Wrazidlo R; Horger M
    Eur J Radiol; 2023 Dec; 169():111153. PubMed ID: 38250749
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Epicardial Adipose Tissue Attenuation and Fat Attenuation Index: Phantom Study and In Vivo Measurements With Photon-Counting Detector CT.
    Mergen V; Ried E; Allmendinger T; Sartoretti T; Higashigaito K; Manka R; Euler A; Alkadhi H; Eberhard M
    AJR Am J Roentgenol; 2022 May; 218(5):822-829. PubMed ID: 34877869
    [No Abstract]   [Full Text] [Related]  

  • 17. Intra-individual comparison of image quality of the coronary arteries between photon-counting detector and energy-integrating detector CT systems.
    Pinos D; Griffith J; Emrich T; Schoepf UJ; O'Doherty J; Zsarnoczay E; Fink N; Vecsey-Nagy M; Suranyi P; Tesche C; Aquino GJ; Varga-Szemes A; Brandt V
    Eur J Radiol; 2023 Sep; 166():111008. PubMed ID: 37542817
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of Photon-counting Detector and Energy-integrating Detector CT for Visual Estimation of Coronary Percent Luminal Stenosis.
    McCollough CH; Rajiah P; Bois JP; Winfree TN; Carter RE; Rajendran K; Williamson EE; Thorne JE; Leng S
    Radiology; 2023 Dec; 309(3):e230853. PubMed ID: 38051190
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Photon Counting Detector CT-Based Virtual Noniodine Reconstruction Algorithm for In Vitro and In Vivo Coronary Artery Calcium Scoring: Impact of Virtual Monoenergetic and Quantum Iterative Reconstructions.
    Fink N; Zsarnoczay E; Schoepf UJ; Griffith JP; Wolf EV; O'Doherty J; Suranyi P; Baruah D; Kabakus IM; Ricke J; Varga-Szemes A; Emrich T
    Invest Radiol; 2023 Sep; 58(9):673-680. PubMed ID: 36822677
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Photon-Counting CT: High-Resolution Imaging of Coronary Stents.
    Mannil M; Hickethier T; von Spiczak J; Baer M; Henning A; Hertel M; Schmidt B; Flohr T; Maintz D; Alkadhi H
    Invest Radiol; 2018 Mar; 53(3):143-149. PubMed ID: 28945655
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.