These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. A generic scope actuation system for flexible endoscopes. Basha S; Khorasani M; Abdurahiman N; Padhan J; Baez V; Al-Ansari A; Tsiamyrtzis P; Becker AT; Navkar NV Surg Endosc; 2024 Feb; 38(2):1096-1105. PubMed ID: 38066193 [TBL] [Abstract][Full Text] [Related]
3. An Actuated Variable-View Rigid Scope System to Assist Visualization in Diagnostic Procedures. Basha S; Khorasani M; Abdurahiman N; Padhan J; Baez V; Al-Ansari A; Tsiamyrtzis P; Becker AT; Navkar NV IEEE J Transl Eng Health Med; 2024; 12():499-507. PubMed ID: 38899143 [TBL] [Abstract][Full Text] [Related]
4. Preliminary design and evaluation of a generic surgical scope adapter. Khorasani M; Abdurahiman N; Padhan J; Zhao H; Al-Ansari A; Becker AT; Navkar N Int J Med Robot; 2023 Apr; 19(2):e2475. PubMed ID: 36288569 [TBL] [Abstract][Full Text] [Related]
5. Evaluation of surgical performance with standard rigid and flexible-tip laparoscopes. Perrone JM; Ames CD; Yan Y; Landman J Surg Endosc; 2005 Oct; 19(10):1325-8. PubMed ID: 16228857 [TBL] [Abstract][Full Text] [Related]
6. Gynecologic laparoscopic surgery with a palm-controlled laparoscope holder. Polet R; Donnez J J Am Assoc Gynecol Laparosc; 2004 Feb; 11(1):73-8. PubMed ID: 15104836 [TBL] [Abstract][Full Text] [Related]
7. On-demand calibration and evaluation for electromagnetically tracked laparoscope in augmented reality visualization. Liu X; Plishker W; Zaki G; Kang S; Kane TD; Shekhar R Int J Comput Assist Radiol Surg; 2016 Jun; 11(6):1163-71. PubMed ID: 27250853 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of the Efficiency of a Joystick-Guided Robotic Scope Holder Compared to That of Human Scopists: A Prospective Trial. Kudo T; Kanaji S; Harada H; Ohmura Y; Sawada R; Urakawa N; Goto H; Hasegawa H; Yamashita K; Matsuda T; Oshikiri T; Kakeji Y Surg Innov; 2023 Oct; 30(5):564-570. PubMed ID: 36788211 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of a novel multi-articulated endoscope: proof of concept through a virtual simulation. Karvonen T; Muranishi Y; Yamamoto G; Kuroda T; Sato T Int J Comput Assist Radiol Surg; 2017 Jul; 12(7):1123-1130. PubMed ID: 28534312 [TBL] [Abstract][Full Text] [Related]
10. Optimal Viewing Direction of the Oblique Laparoscope in Single-Incision Laparoscopic Percutaneous Extraperitoneal Closure for Inguinal Hernia. Takazawa S; Koyama R; Takamoto N; Nishi A J Laparoendosc Adv Surg Tech A; 2021 Feb; 31(2):216-219. PubMed ID: 33232635 [No Abstract] [Full Text] [Related]
11. Postural mechatronic assistant for laparoscopic solo surgery (PMASS). Minor Martinez A; Villalobos Gomez J; Ordorica Flores R; Lorias Espinoza D Surg Endosc; 2009 Mar; 23(3):663-7. PubMed ID: 18528612 [TBL] [Abstract][Full Text] [Related]
12. Comparison of six display modes for a multi-resolution foveated laparoscope. Lee S; Hua H; Nguyen M; Hamilton AJ Surg Endosc; 2019 Jan; 33(1):341-351. PubMed ID: 30206684 [TBL] [Abstract][Full Text] [Related]
13. Easy cleaning of the scope's lens in a syringe to prevent condensation during laparoscopic surgery. Runia AJ; Zengerink JF; Mannaerts GH Surg Endosc; 2009 Dec; 23(12):2849-50. PubMed ID: 19707825 [TBL] [Abstract][Full Text] [Related]
14. Short rigid scope and stereo-scope designed specifically for open abdominal navigation surgery: clinical application for hepatobiliary and pancreatic surgery. Onda S; Okamoto T; Kanehira M; Fujioka S; Suzuki N; Hattori A; Yanaga K J Hepatobiliary Pancreat Sci; 2013 Apr; 20(4):448-53. PubMed ID: 23269461 [TBL] [Abstract][Full Text] [Related]
15. Automated instrument tracking in robotically assisted laparoscopic surgery. Uecker DR; Lee C; Wang YF; Wang Y J Image Guid Surg; 1995; 1(6):308-25. PubMed ID: 9080352 [TBL] [Abstract][Full Text] [Related]
16. A novel modification of traditional 2-port laparoscopic surgery using a 5-mm flexible scope. Kikuchi I; Kumakiri J; Kuroda K; Matsuoka S; Kitade M; Takeda S J Minim Invasive Gynecol; 2009; 16(6):734-8. PubMed ID: 19896600 [TBL] [Abstract][Full Text] [Related]
17. Laparoscopic lens fogging: solving a common surgical problem in standard and robotic laparoscopes via a scientific model. Manning TG; Papa N; Perera M; McGrath S; Christidis D; Khan M; O'Beirne R; Campbell N; Bolton D; Lawrentschuk N Surg Endosc; 2018 Mar; 32(3):1600-1606. PubMed ID: 28791559 [TBL] [Abstract][Full Text] [Related]
18. Camera and instrument holders and their clinical value in minimally invasive surgery. Jaspers JE; Breedveld P; Herder JL; Grimbergen CA Surg Laparosc Endosc Percutan Tech; 2004 Jun; 14(3):145-52. PubMed ID: 15471021 [TBL] [Abstract][Full Text] [Related]
19. An improved camera model for oblique-viewing laparoscopes: high reprojection accuracy independent of telescope rotation. Eppenga R; Snaauw G; Kuhlmann K; van der Heijden F; Ruers T; Nijkamp J Phys Med Biol; 2023 Sep; 68(18):. PubMed ID: 37582390 [No Abstract] [Full Text] [Related]
20. Visualization of endometriosis: comparative study of 3-dimensional robotic and 2-dimensional laparoscopic endoscopes. Mosbrucker C; Somani A; Dulemba J J Robot Surg; 2018 Mar; 12(1):59-66. PubMed ID: 28255736 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]