These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 36751162)

  • 1. Annular Rupture Due to Calcified Nodule Located in Left Ventricular Outflow Tract (LVOT) During Transcatheter Aortic Valve Replacement (TAVR) Managed by Protamine Sulfate.
    Chauhan S; Bhatnagar M; Jilani TN; Levisman J
    Cureus; 2023 Jan; 15(1):e33417. PubMed ID: 36751162
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement.
    Barbanti M; Yang TH; Rodès Cabau J; Tamburino C; Wood DA; Jilaihawi H; Blanke P; Makkar RR; Latib A; Colombo A; Tarantini G; Raju R; Binder RK; Nguyen G; Freeman M; Ribeiro HB; Kapadia S; Min J; Feuchtner G; Gurtvich R; Alqoofi F; Pelletier M; Ussia GP; Napodano M; de Brito FS; Kodali S; Norgaard BL; Hansson NC; Pache G; Canovas SJ; Zhang H; Leon MB; Webb JG; Leipsic J
    Circulation; 2013 Jul; 128(3):244-53. PubMed ID: 23748467
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bespoke valve sizing avoids annular rupture in patients treated with a balloon-expandable transcatheter heart valve.
    Chavarria J; Falcao F; Dutra G; Sathananthan J; Wood D; Douvi G; Natarajan M; Jaffer I; Velianou J; Sheth T
    Catheter Cardiovasc Interv; 2022 Nov; 100(5):823-831. PubMed ID: 36153648
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Impact of Left Ventricular Outflow Tract Calcification on Procedural Outcomes After Transcatheter Aortic Valve Replacement.
    Okuno T; Asami M; Heg D; Lanz J; Praz F; Hagemeyer D; Brugger N; Gräni C; Huber A; Spirito A; Räber L; Stortecky S; Windecker S; Pilgrim T
    JACC Cardiovasc Interv; 2020 Aug; 13(15):1789-1799. PubMed ID: 32763071
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Balloon Versus Computed Tomography Sizing of the Aortic Annulus for Transcatheter Aortic Valve Replacement and the Impact of Left Ventricular Outflow Tract Calcification and Morphology on Sizing.
    Condado JF; Lerakis S; Stewart J; Jensen H; Henry TS; Ko SM; Stillman A; Rajaei MH; Mavromatis K; Devireddy C; Sarin E; Leshnower B; Guyton R; Kaebnick B; Thourani VH; Block PC; Babaliaros V
    J Invasive Cardiol; 2016 Jul; 28(7):295-304. PubMed ID: 27101969
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The impact of calcium volume and distribution in aortic root injury related to balloon-expandable transcatheter aortic valve replacement.
    Hansson NC; Nørgaard BL; Barbanti M; Nielsen NE; Yang TH; Tamburino C; Dvir D; Jilaihawi H; Blanke P; Makkar RR; Latib A; Colombo A; Tarantini G; Raju R; Wood D; Andersen HR; Ribeiro HB; Kapadia S; Min J; Feuchtner G; Gurvitch R; Alqoofi F; Pelletier M; Ussia GP; Napodano M; Sandoli de Brito F; Kodali S; Pache G; Canovas SJ; Berger A; Murphy D; Svensson LG; Rodés-Cabau J; Leon MB; Webb JG; Leipsic J
    J Cardiovasc Comput Tomogr; 2015; 9(5):382-92. PubMed ID: 26164109
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Subannular perforation of left ventricular outflow tract associated with transcatheter valve implantation: pathophysiological background and clinical implications.
    Girdauskas E; Owais T; Fey B; Kuntze F; Lauer B; Borger MA; Conradi L; Reichenspurner H; Kuntze T
    Eur J Cardiothorac Surg; 2017 Jan; 51(1):91-96. PubMed ID: 27412343
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Optimal sizing for SAPIEN 3 transcatheter aortic valve replacement in patients with or without left ventricular outflow tract calcification.
    Maeno Y; Abramowitz Y; Jilaihawi H; Israr S; Yoon S; Sharma RP; Kazuno Y; Kawamori H; Miyasaka M; Rami T; Mangat G; Takahashi N; Okuyama K; Kashif M; Chakravarty T; Nakamura M; Cheng W; Makkar RR
    EuroIntervention; 2017 Apr; 12(18):e2177-e2185. PubMed ID: 28117281
    [TBL] [Abstract][Full Text] [Related]  

  • 9. 'Touchdown' technique during self-expandable transcatheter aortic valve replacement in patient with severe left ventricular outflow tract calcification: a case report.
    Tsuda M; Egami Y; Kawanami S; Nishino M
    Eur Heart J Case Rep; 2023 Apr; 7(4):ytad143. PubMed ID: 37057277
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of Left Ventricular Outflow Tract Calcification on Outcomes Following Transcatheter Aortic Valve Replacement.
    Musallam A; Buchanan KD; Yerasi C; Dheendsa A; Zhang C; Shea C; Case BC; Forrestal BJ; Satler LF; Ben-Dor I; Torguson R; Rogers T; Waksman R
    Cardiovasc Revasc Med; 2022 Feb; 35():1-7. PubMed ID: 34598904
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Novel Lithotripsy-Assisted Transcatheter Aortic Valve Replacement May Reduce Risk of Aortic Root Rupture.
    Seshiah P; Choo J; Garcia S; Kereiakes DJ
    J Soc Cardiovasc Angiogr Interv; 2023; 2(6Part A):101111. PubMed ID: 39129883
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ruptures of the device landing zone in patients undergoing transcatheter aortic valve implantation: an analysis of TAVI Karlsruhe (TAVIK) patients.
    Schymik G; Heimeshoff M; Bramlage P; Wondraschek R; Süselbeck T; Gerhardus J; Luik A; Posival H; Schmitt C; Schröfel H
    Clin Res Cardiol; 2014 Nov; 103(11):912-20. PubMed ID: 24908338
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Aortic valve and left ventricular outflow tract calcium volume and distribution in transcatheter aortic valve replacement: Influence on the risk of significant paravalvular regurgitation.
    Hansson NC; Leipsic J; Pugliese F; Andersen HR; Rossi A; Simonato M; Jensen KT; Christiansen EH; Terkelsen CJ; Blanke P; Tang M; Krusell LR; Klaaborg KE; Terp K; Kennon S; Dvir D; Bøtker HE; Webb J; Nørgaard BL
    J Cardiovasc Comput Tomogr; 2018; 12(4):290-297. PubMed ID: 29519754
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Percutaneous Management of a Contained Annular Rupture Occurring With Self-Expanding Transcatheter Aortic Valve Replacement.
    Kellogg MS; Tuttle MK; Sharma RK; Mehta SV; Laham RJ
    JACC Case Rep; 2020 Oct; 2(12):1852-1858. PubMed ID: 34317066
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impact of Aortic Root Anatomy and Geometry on Paravalvular Leak in Transcatheter Aortic Valve Replacement With Extremely Large Annuli Using the Edwards SAPIEN 3 Valve.
    Tang GHL; Zaid S; George I; Khalique OK; Abramowitz Y; Maeno Y; Makkar RR; Jilaihawi H; Kamioka N; Thourani VH; Babaliaros V; Webb JG; Htun NM; Attinger-Toller A; Ahmad H; Kaple R; Sharma K; Kozina JA; Kaneko T; Shah P; Hirji SA; Desai ND; Anwaruddin S; Jagasia D; Herrmann HC; Basra SS; Szerlip MA; Mack MJ; Mathur M; Tan CW; Don CW; Sharma R; Gafoor S; Zhang M; Kapadia SR; Mick SL; Krishnaswamy A; Amoroso N; Salemi A; Wong SC; Kini AS; Rodés-Cabau J; Leon MB; Kodali SK
    JACC Cardiovasc Interv; 2018 Jul; 11(14):1377-1387. PubMed ID: 29960755
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Association of Relative Left Ventricular Outflow Tract Area and Transcatheter Aortic Valve Replacement Related Paravalvular Leak.
    Gupta K; Villablanca P; Gonzalez PE; O'Neill B; O'Neill WW; Wang DD; Fang JX; Giustino G; Frisoli T; Lee JC
    J Soc Cardiovasc Angiogr Interv; 2024 Mar; 3(3Part B):101294. PubMed ID: 39131220
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Impact of left ventricle outflow tract calcification on the outcomes of transcatheter aortic valve implantation: A study-level meta-analysis.
    Sá MP; Van den Eynde J; Malin JH; Torregrossa G; Sicouri S; Ramlawi B
    J Card Surg; 2022 May; 37(5):1379-1390. PubMed ID: 35152472
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Quantity and location of aortic valve calcification predicts paravalvular leakage after transcatheter aortic valve replacement: a systematic review and meta-analysis.
    Shi J; Li W; Zhang T; Han C; Wang Z; Pei X; Li X; Zhao Z; Wang P; Han J; Chen S
    Front Cardiovasc Med; 2023; 10():1170979. PubMed ID: 37293280
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Paravalvular leak after transcatheter aortic valve implantation: is it anatomically predictable or procedurally determined? MDCT study.
    Sakrana AA; Nasr MM; Ashamallah GA; Abuelatta RA; Naeim HA; Tahlawi ME
    Clin Radiol; 2016 Nov; 71(11):1095-103. PubMed ID: 27612848
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Extent and distribution of calcification of both the aortic annulus and the left ventricular outflow tract predict aortic regurgitation after transcatheter aortic valve replacement.
    Buellesfeld L; Stortecky S; Heg D; Gloekler S; Meier B; Wenaweser P; Windecker S
    EuroIntervention; 2014 Oct; 10(6):732-8. PubMed ID: 25330505
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.