These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 36751162)

  • 21. Early Clinical Outcomes of Transcatheter Aortic Valve Replacement in Left Ventricular Outflow Tract Calcification: New-Generation Device vs Early-Generation Device.
    Nomura T; Maeno Y; Yoon SH; Abramowitz Y; Israr S; Miyasaka M; Kazuno Y; Takahashi N; Kawamori H; Nakamura M; Jilaihawi H; Makkar RR
    J Invasive Cardiol; 2018 Nov; 30(11):421-427. PubMed ID: 30373952
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Imaging in patients with severe mitral annular calcification: insights from a multicentre experience using transatrial balloon-expandable valve replacement.
    Praz F; Khalique OK; Lee R; Wu IY; Russell H; Guerrero M; Wang DD; Veeragandham R; Islam AM; Deaton DW; Kaneko T; Eudailey KW; Akkoc D; Kantor A; Wang C; Tang DCH; Park JS; Leung D; Nazif TM; Vahl TP; Hahn RT; Kodali SK; Leon MB; Takayama H; Bapat V; Borger MA; George I
    Eur Heart J Cardiovasc Imaging; 2019 Dec; 20(12):1395-1406. PubMed ID: 31220240
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Impact of left ventricular outflow tract calcium on valve geometry in self-expanding transcatheter aortic-valve replacement.
    Medranda GA; Rogers T; Fuery M; Case BC; Collins EC; Ali SW; Zhang C; Wang JC; Weissman G; Cohen JE; Shults CC; Satler LF; Ben-Dor I; Waksman R
    Catheter Cardiovasc Interv; 2022 Sep; 100(3):404-412. PubMed ID: 35723247
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Aortic root rupture during balloon-expandable transcatheter aortic valve replacement in a patient without recognized risk factors for aortic root rupture: a case report.
    Tsuda M; Mizote I; Mukai T; Sakata Y
    Eur Heart J Case Rep; 2020 Jun; 4(3):1-4. PubMed ID: 32617490
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Open-heart transseptal transcatheter mitral valve implantation with mitral annular calcification.
    Morita S; Takahashi S; Pernot M; Leroux L; Labrousse L
    J Cardiol Cases; 2020 Nov; 22(5):207-209. PubMed ID: 33133310
    [TBL] [Abstract][Full Text] [Related]  

  • 26. How valvular calcification can affect the outcomes of transcatheter aortic valve implantation.
    Milhorini Pio S; Bax J; Delgado V
    Expert Rev Med Devices; 2020 Aug; 17(8):773-784. PubMed ID: 32597265
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Improving the accuracy of effective orifice area assessment after transcatheter aortic valve replacement: validation of left ventricular outflow tract diameter and pulsed-wave Doppler location and impact of three-dimensional measurements.
    Khalique OK; Hamid NB; Kodali SK; Nazif TM; Marcoff L; Paradis JM; Williams MR; Vahl TP; George I; Leon MB; Hahn RT
    J Am Soc Echocardiogr; 2015 Nov; 28(11):1283-93. PubMed ID: 26323890
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Concomitant Redo Transcatheter Aortic Valve Replacement and Valve-in-Mitral Annular Calcification.
    Nagaraja V; Borges N; Krishnaswamy A; Yun J; Kapadia SR
    JACC Case Rep; 2022 May; 4(9):512-515. PubMed ID: 35573844
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Aortic annulus rupture during transcatheter aortic valve implantation: complication prevention and management].
    Ancona MB; Cianfanelli L; Romano V; Montorfano M
    G Ital Cardiol (Rome); 2020 Nov; 21(11 Suppl 1):13S-16S. PubMed ID: 33295330
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Anatomical risk models for paravalvular leak and landing zone complications for balloon-expandable transcatheter aortic valve replacement.
    Condado JF; Corrigan FE; Lerakis S; Parastatidis I; Stillman AE; Binongo JN; Stewart J; Mavromatis K; Devireddy C; Leshnower B; Guyton R; Forcillo J; Patel A; Thourani VH; Block PC; Babaliaros V
    Catheter Cardiovasc Interv; 2017 Oct; 90(4):690-700. PubMed ID: 28471092
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Risk factors of perivalvular leakage after transcatheter aortic valve replacement with Venus-A valve].
    Wang Y; Luo XL; Zhang C; Liu T; Zeng Y; Rao RS; Qian DH; Yu SY; Jin J
    Zhonghua Xin Xue Guan Bing Za Zhi; 2021 Jul; 49(7):694-700. PubMed ID: 34256437
    [No Abstract]   [Full Text] [Related]  

  • 32. TAVR for Severe Aortic Valve Stenosis with LVOT Stenosis: A Case Report.
    Zhang Q; Xu Y; Wang H; Pang X; Meng Q
    Int Med Case Rep J; 2024; 17():719-723. PubMed ID: 39100686
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A revised methodology for aortic-valvar complex calcium quantification for transcatheter aortic valve implantation.
    Jilaihawi H; Makkar RR; Kashif M; Okuyama K; Chakravarty T; Shiota T; Friede G; Nakamura M; Doctor N; Rafique A; Shibayama K; Mihara H; Trento A; Cheng W; Friedman J; Berman D; Fontana GP
    Eur Heart J Cardiovasc Imaging; 2014 Dec; 15(12):1324-32. PubMed ID: 25187618
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Patho-Histological Findings of Annular Rupture Related to Left Ventricular Outflow Tract (LVOT) Calcification Following Transcatheter Aortic Valve Replacement (TAVR).
    Kalra A; Pedersen WR; Mackey-Bojack SM; Duncanson ER; Harris KM
    J Heart Valve Dis; 2016 May; 25(3):296-300. PubMed ID: 27989039
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Combination Use of Inoue-Balloon and Self-Expandable Transcatheter Valves in Managing Aortic Stenosis Not Amenable to Balloon-Expandable Valves.
    Saji M; Highchi R; Iguchi N; Takamisawa I; Shimizu J; Shimokawa T; Nanasato M; Takayama M; Isobe M
    Int Heart J; 2022; 63(5):843-851. PubMed ID: 36184546
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Annular rupture during transcatheter aortic valve replacement: classification, pathophysiology, diagnostics, treatment approaches, and prevention.
    Pasic M; Unbehaun A; Buz S; Drews T; Hetzer R
    JACC Cardiovasc Interv; 2015 Jan; 8(1 Pt A):1-9. PubMed ID: 25616813
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Special considerations in mapping and ablation of focal ventricular arrhythmias originating from the left ventricular outflow tract in patients with a transcatheter aortic valve replacement.
    Yamada T
    J Cardiovasc Electrophysiol; 2019 Nov; 30(11):2640-2647. PubMed ID: 31512333
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Impact of Left Ventricular Outflow Tract Calcium on Hemodynamics and Outcomes in Patients After Transcatheter Aortic Valve Implantation With a Contemporary Self-Expanding Valve.
    Medranda GA; Rogers T; Case BC; Ali SW; Zhang C; Wang JC; Weissman G; Satler LF; Ben-Dor I; Waksman R
    Am J Cardiol; 2022 Apr; 168():128-134. PubMed ID: 35067347
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Impact of device landing zone calcification on paravalvular regurgitation after transcatheter aortic valve replacement: a real-time three-dimensional transesophageal echocardiographic study.
    Mihara H; Shibayama K; Berdejo J; Harada K; Itabashi Y; Siegel RJ; Kashif M; Jilaihawi H; Makkar RR; Shiota T
    J Am Soc Echocardiogr; 2015 Apr; 28(4):404-14. PubMed ID: 25560483
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography.
    Ng AC; Delgado V; van der Kley F; Shanks M; van de Veire NR; Bertini M; Nucifora G; van Bommel RJ; Tops LF; de Weger A; Tavilla G; de Roos A; Kroft LJ; Leung DY; Schuijf J; Schalij MJ; Bax JJ
    Circ Cardiovasc Imaging; 2010 Jan; 3(1):94-102. PubMed ID: 19920027
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.