These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 3675152)

  • 1. Automated three-part leukocyte differential counts in the preoperative evaluation of ambulatory surgery patients.
    Kalish RJ; Goldberg G; Roberts K; Schwartz S; Iorio C
    Arch Pathol Lab Med; 1987 Dec; 111(12):1155-7. PubMed ID: 3675152
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Elimination of instrument-driven reflex manual differential leukocyte counts. Optimization of manual blood smear review criteria in a high-volume automated hematology laboratory.
    Lantis KL; Harris RJ; Davis G; Renner N; Finn WG
    Am J Clin Pathol; 2003 May; 119(5):656-62. PubMed ID: 12760283
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Automated five-part white blood cell differential counts. Efficiency of software-generated white blood cell suspect flags of the hematology analyzers Sysmex SE-9000, Sysmex NE-8000, and Coulter STKS.
    Thalhammer-Scherrer R; Knöbl P; Korninger L; Schwarzinger I
    Arch Pathol Lab Med; 1997 Jun; 121(6):573-7. PubMed ID: 9199621
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Automated differential leukocyte counts.
    Morse EE; Nashed A; Spilove L
    Ann Clin Lab Sci; 1989; 19(3):155-60. PubMed ID: 2658725
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of the Coulter S-Plus V three-part differential in a community hospital, including criteria for its use.
    Kalish RJ; Becker K
    Am J Clin Pathol; 1986 Dec; 86(6):751-5. PubMed ID: 3788862
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of the Beckman Coulter AcT 5 diff AL hematology analyzer in a hospital setting.
    Bhuta UM; Ulstein H
    Lab Hematol; 2003; 9(3):167-74. PubMed ID: 14521325
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Automated leucocyte differentials in 292 patients with leucopenia: an evaluation of the Abbott CELL-DYN 3500 (CD3500) haematology analyser.
    Burchert-Graeve M; Kock R
    Clin Lab Haematol; 1996 Dec; 18(4):253-9. PubMed ID: 9054698
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Further evolution and leukocyte differential using an automated blood cell counter].
    Takubo T; Tatsumi N
    Rinsho Byori; 1995 Sep; 43(9):925-30. PubMed ID: 7474456
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Process to evaluate hematological parameters that reflex to manual differential cell counts in a pediatric institution.
    Guarner J; Atuan MA; Nix B; Mishak C; Vejjajiva C; Curtis C; Park S; Mullins R
    Clin Lab; 2010; 56(1-2):21-7. PubMed ID: 20380356
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of an automated method for leukocyte differential counts based on electronic volume analysis.
    Allen JK; Batjer JD
    Arch Pathol Lab Med; 1985 Jun; 109(6):534-9. PubMed ID: 3838883
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Complete analytical and diagnostic performances of the Abbott Cell Dyn 3500.
    Sanzari M; De Toni S; D'Osualdo A; Rossetti M; Floriani F; Plebani M
    Panminerva Med; 1998 Jun; 40(2):116-25. PubMed ID: 9689832
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Evaluation of the Coulter Counter S+IV LMG: estimation of the leukocyte formula. Comparison with microscopic methods].
    Tarallo P; Henny J; Siest G; Humbert JC
    Ann Biol Clin (Paris); 1986; 44(1):49-53. PubMed ID: 3706832
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A clinical trial of three-part electronic differential white blood cell counts.
    Charache S; Nelson L; Keyser E; Metzger P
    Arch Intern Med; 1985 Oct; 145(10):1852-5. PubMed ID: 3899037
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative evaluation of differential leukocyte counts by Coulter VCS cytometer and direct microscopic observation.
    Zaccaria A; Celso B; Raspadori D; Motta MR; Testoni N; Rizzi S
    Haematologica; 1990; 75(5):412-9. PubMed ID: 2097260
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical performance of leukocyte differential on the new Roche Cobas Vega haematological analyzer.
    Lippi G; Nicoli M; Modena N; Guidi G
    Eur J Clin Chem Clin Biochem; 1997 Feb; 35(2):105-10. PubMed ID: 9056752
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Use of Coulter VCS for differential leukocyte counts.
    Picard F; Terroux N; Levy JP
    Nouv Rev Fr Hematol (1978); 1990; 32(3):211-6. PubMed ID: 2216705
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Comparative and simultaneous evaluation of three automated counters in hematology: Coulter STKS, Sysmex NE 8000, Technicon H-2].
    Cart-Lamy P; Pernod G; Pirraud M; Drevait JM; Caillat D; Polack B; Kolodié L
    Ann Biol Clin (Paris); 1993; 51(6):627-35. PubMed ID: 8172402
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of the automated leucocyte count and differential from the Cell-Dyn 3500 in sickle cell disease.
    Joyner RE; Brooks MJ
    Clin Lab Haematol; 1995 Dec; 17(4):329-33. PubMed ID: 8697728
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of the Coulter S-Plus IV three-part differential in an acute care hospital.
    Griswold DJ; Champagne VD
    Am J Clin Pathol; 1985 Jul; 84(1):49-57. PubMed ID: 4014075
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of an automatic hematology analyzer in patients with nonhematologic conditions.
    Lam CP; Fan HC; Chiang H; Ho CH
    Adv Ther; 1997; 14(5):234-44. PubMed ID: 10174619
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.