BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 36754947)

  • 1. Patient dose reduction for a localizer radiograph with an additional tin filter in chest-abdomen-pelvis, spine, and head computed tomography examinations.
    Takemitsu M; Takegami K; Kudomi S; Kawanami K
    Radiol Phys Technol; 2023 Jun; 16(2):160-167. PubMed ID: 36754947
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Technical Note: Radiation dose reduction from computed tomography localizer radiographs using a tin spectral shaping filter.
    Saltybaeva N; Krauss A; Alkadhi H
    Med Phys; 2019 Feb; 46(2):544-549. PubMed ID: 30578731
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Impact of tin filter on the image quality of ultra-low dose chest CT: A phantom study on three CT systems.
    Greffier J; Fitton I; Ngoc Ty CV; Frandon J; Beregi JP; Dabli D
    Diagn Interv Imaging; 2023 Oct; 104(10):506-512. PubMed ID: 37286462
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Radiation dose reduction using spectral shaping in pediatric non-contrast sinus CT.
    Zhou W; Malave MN; Maloney JA; White C; Weinman JP; Huo D; Neuberger I
    Pediatr Radiol; 2023 Sep; 53(10):2069-2078. PubMed ID: 37341726
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Low-Dose CT Imaging of the Pelvis in Follow-up Examinations-Significant Dose Reduction and Impact of Tin Filtration: Evaluation by Phantom Studies and First Systematic Retrospective Patient Analyses.
    Schüle S; Gärtner K; Halt D; Beer M; Hackenbroch C
    Invest Radiol; 2022 Dec; 57(12):789-801. PubMed ID: 35776429
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dose Optimization for Computed Tomography Localizer Radiographs for Low-Dose Lung Computed Tomography Examinations.
    Schmidt BT; Hupfer M; Saltybaeva N; Kolditz D; Kalender WA
    Invest Radiol; 2017 Feb; 52(2):81-86. PubMed ID: 27518213
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optimizing radiation exposure for CT localizer radiographs.
    Bohrer E; Schäfer S; Mäder U; Noël PB; Krombach GA; Fiebich M
    Z Med Phys; 2017 Jun; 27(2):145-158. PubMed ID: 27720574
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Spectral Beam Shaping in Unenhanced Chest CT Examinations: A Phantom Study on Dose Reduction and Image Quality.
    Suntharalingam S; Allmendinger T; Blex S; Al-Bayati M; Nassenstein K; Schweiger B; Forsting M; Wetter A
    Acad Radiol; 2018 Feb; 25(2):153-158. PubMed ID: 29055683
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dose Reduction for Sinus and Temporal Bone Imaging Using Photon-Counting Detector CT With an Additional Tin Filter.
    Rajendran K; Voss BA; Zhou W; Tao S; DeLone DR; Lane JI; Weaver JM; Carlson ML; Fletcher JG; McCollough CH; Leng S
    Invest Radiol; 2020 Feb; 55(2):91-100. PubMed ID: 31770297
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy and Radiation Dose Reduction Using Low-Voltage Computed Tomography Coronary Artery Calcium Scoring With Tin Filtration.
    Tesche C; De Cecco CN; Vliegenthart R; Albrecht MH; Varga-Szemes A; Duguay TM; Ebersberger U; Bayer RR; Canstein C; Schmidt B; Allmendinger T; Litwin SE; Morris PB; Flohr TG; Hoffmann E; Schoepf UJ
    Am J Cardiol; 2017 Feb; 119(4):675-680. PubMed ID: 27986261
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Chest CT screening in patients with overweight or obesity using spectral shaping at 150 kVp: compared with 120 kVp protocol and spectral shaping at 100 kVp protocol.
    Li J; Mai Z; Zhang Z; Cui J; Yang M; Ma X; Wang Y
    Jpn J Radiol; 2020 May; 38(5):451-457. PubMed ID: 32048134
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Patient dose increase caused by posteroanterior CT localizer radiographs.
    Urikura A; Miyauchi Y; Yoshida T; Ishita Y; Takiguchi K; Endo M; Aramaki T
    Radiography (Lond); 2023 Mar; 29(2):334-339. PubMed ID: 36709524
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Coronary artery calcium score scan at 100 kVp with tin filtration (Sn100 kVp) prior to coronary computed tomography angiography for overall radiation dose reduction: a prospective cohort study.
    Jin L; Wang K; Li M
    Quant Imaging Med Surg; 2022 Sep; 12(9):4529-4537. PubMed ID: 36060595
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Influence of Different Arm Positions in the Localizer Radiograph(s) on Patient Dose during Exposure-Controlled CT Examinations of the Neck to Pelvis.
    Svahn TM; Peric L; Ast JC
    Tomography; 2021 Jul; 7(3):313-322. PubMed ID: 34449741
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Tin-filtered low-dose chest CT to quantify macroscopic calcification burden of the thoracic aorta.
    Schabel C; Marin D; Ketelsen D; Farjat AE; Bier G; Lescan M; Bamberg F; Nikolaou K; Bongers MN
    Eur Radiol; 2018 May; 28(5):1818-1825. PubMed ID: 29196856
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Radiation Exposure in Computed Tomography Localizer Radiograph].
    Sato T; Kikuchi Y; Nakamura M; Saito N; Arai Y
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2019; 75(12):1403-1410. PubMed ID: 31866638
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ultralow-dose CT with tin filtration for detection of solid and sub solid pulmonary nodules: a phantom study.
    Martini K; Higashigaito K; Barth BK; Baumueller S; Alkadhi H; Frauenfelder T
    Br J Radiol; 2015; 88(1056):20150389. PubMed ID: 26492317
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A tin filter's dose reduction effect revisited: Using the detectability index in low-dose computed tomography for the chest.
    Hasegawa A; Ichikawa K; Morioka Y; Kawashima H
    Phys Med; 2022 Jul; 99():61-67. PubMed ID: 35623206
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dual-source photon counting detector CT with a tin filter: a phantom study on iodine quantification performance.
    Tao A; Huang R; Tao S; Michalak GJ; McCollough CH; Leng S
    Phys Med Biol; 2019 May; 64(11):115019. PubMed ID: 31018197
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Feasibility study of ultra-low-dose dedicated maxillofacial computed tomography using filter-based spectral shaping in patients with craniofacial trauma: assessment of image quality and radiation dose.
    Ha JY; Baek HJ; Ryu KH; Cho E
    Quant Imaging Med Surg; 2021 Apr; 11(4):1292-1302. PubMed ID: 33816168
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.