These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 36756786)

  • 1. Treatment of severe aortic valve regurgitation with the Trilogy TAVI system.
    Yokoyama H; Tamm AR; Geyer M; Munzel T; Treede H; von Bardeleben RS
    EuroIntervention; 2023 Apr; 18(17):1444-1445. PubMed ID: 36756786
    [No Abstract]   [Full Text] [Related]  

  • 2. Percutaneous paravalvular leak repair for severe aortic regurgitation after transcatheter aortic valve implantation (TAVI).
    Chiam PT; Lim CP; Lim YT; Sivathasan C
    Ann Acad Med Singap; 2021 Mar; 50(3):274-276. PubMed ID: 33855328
    [No Abstract]   [Full Text] [Related]  

  • 3. Valve-in-Valve Transcatheter Aortic Valve Replacement for the Treatment of Paravalvular Leak Due to Ring Dehiscence.
    Demirel C; Okuno T; Lanz J; Windecker S; Pilgrim T
    JACC Cardiovasc Interv; 2021 Dec; 14(24):2746-2748. PubMed ID: 34838466
    [No Abstract]   [Full Text] [Related]  

  • 4. Transcatheter aortic valve implantation 10 years after valve-in-valve transcatheter aortic valve implantation for failing aortic valve homograft root replacement.
    Duncan A; Mirsadree S; Quarto C; Davies S
    Catheter Cardiovasc Interv; 2020 Jul; 96(1):228-235. PubMed ID: 31854041
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transcatheter aortic valve implantation using J-Valve in an elderly patient with severe aortic regurgitation.
    Liu L; Chen M; Chen B; Guo Y
    J Card Surg; 2021 Jul; 36(7):2565-2568. PubMed ID: 33797796
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Novel Transfemoral TAVR System to Treat Aortic Regurgitation in Degenerated Surgical Aortic Valve Replacement Even in Unfavorable Anatomy.
    Geyer M; Tamm AR; Münzel T; Treede H; von Bardeleben RS
    JACC Cardiovasc Interv; 2022 Jun; 15(11):e135-e136. PubMed ID: 35568645
    [No Abstract]   [Full Text] [Related]  

  • 7. Transcatheter aortic valve implantation for severe pure aortic regurgitation due to active aortitis.
    Ruggiero R; Ponticelli F; Giannini F; Galvani M
    Catheter Cardiovasc Interv; 2021 Apr; 97(5):950-954. PubMed ID: 32865314
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Aortic valve-in-valve implantation requiring valve fracturing via a subclavian access: new insights with a word of caution.
    Russo M; Werner P; Kastner J; Andreas M
    J Cardiovasc Med (Hagerstown); 2019 Nov; 20(11):787-791. PubMed ID: 31449177
    [No Abstract]   [Full Text] [Related]  

  • 9. A Novel Designed TAVR System for Pure Aortic Regurgitation: First-in-Human Experience.
    Liu L; Qin C; Shi J; Guo Y
    JACC Cardiovasc Interv; 2023 Nov; 16(21):2690-2691. PubMed ID: 37804293
    [No Abstract]   [Full Text] [Related]  

  • 10. The retro-antegrade approach to paravalvular leak closure after transcatheter aortic valve replacement.
    So CY; Kang G; Lee JC; Eng MH
    EuroIntervention; 2020 Oct; 16(9):e763-e764. PubMed ID: 32176617
    [No Abstract]   [Full Text] [Related]  

  • 11. Transcatheter Aortic Valve Replacement for Pure Aortic Regurgitation in a Large and Noncalcified Annulus.
    Orzalkiewicz M; Bruno AG; Taglieri N; Ghetti G; Marrozzini C; Galiè N; Palmerini T; Saia F
    JACC Cardiovasc Interv; 2021 Oct; 14(19):e271-e273. PubMed ID: 34538599
    [No Abstract]   [Full Text] [Related]  

  • 12. Transcatheter aortic valve in valve implantation with bioprosthetic valve fracture.
    James TM; Stamou SC; Rothenberg M; Nores MA
    Catheter Cardiovasc Interv; 2019 May; 93(6):1170-1172. PubMed ID: 30790421
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transfemoral transcatheter aortic valve replacement for pure aortic regurgitation.
    Wernly B; Jung C
    Lancet; 2024 Apr; 403(10435):1420-1421. PubMed ID: 38552657
    [No Abstract]   [Full Text] [Related]  

  • 14. Transfemoral transcatheter aortic valve replacement in the presence of a mitral prosthesis.
    Toutouzas K; Drakopoulou M; Latsios G; Synetos A; Stathogiannis K; Soulaidopoulos S; Oikonomou G; Trantalis G; Papanikolaou A; Aggeli C; Vavuranakis M; Mastrokostopoulos A; Katsimaglis G; Voudris V; Dardas P; Tousoulis D
    J Cardiovasc Med (Hagerstown); 2019 Dec; 20(12):825-830. PubMed ID: 31592849
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Weighing Transcatheter Aortic Valve Replacement vs Surgical Aortic Valve Replacement for Native Aortic Regurgitation.
    Ranard LS; Vahl TP; Thourani VH
    Ann Thorac Surg; 2023 Apr; 115(4):877-878. PubMed ID: 36773830
    [No Abstract]   [Full Text] [Related]  

  • 16. What is old is new again: Making sense of aortic paravalvular leaks - Silent but deadly.
    Langer NB; Vlahakes GJ
    J Card Surg; 2022 Sep; 37(9):2607-2609. PubMed ID: 35661261
    [No Abstract]   [Full Text] [Related]  

  • 17. Transcatheter aortic valve replacement in a patient with severe aortic regurgitation following left ventricular assist device implantation.
    Trębacz J; Wierzbicki K; Sobczyński R; Konstanty-Kalandyk J; Stąpór M; Okarski M; Kapelak B; Legutko J; Kleczyński P
    Kardiol Pol; 2023; 81(1):68-69. PubMed ID: 36106849
    [No Abstract]   [Full Text] [Related]  

  • 18. TAVR in Bicuspid Valve With Pure Aortic Regurgitation: Prosthesis Sizing According to the LIRA Method.
    Bellini B; Iannopollo G; Buzzatti N; Romano V; Melillo F; Ancona MB; Vella C; Ferri L; Russo F; Montorfano M
    JACC Cardiovasc Interv; 2021 Oct; 14(19):e263-e265. PubMed ID: 34391708
    [No Abstract]   [Full Text] [Related]  

  • 19. 1-Year Results in Patients Undergoing Transcatheter Aortic Valve Replacement With Failed Surgical Bioprostheses.
    Deeb GM; Chetcuti SJ; Reardon MJ; Patel HJ; Grossman PM; Schreiber T; Forrest JK; Bajwa TK; O'Hair DP; Petrossian G; Robinson N; Katz S; Hartman A; Dauerman HL; Schmoker J; Khabbaz K; Watson DR; Yakubov SJ; Oh JK; Li S; Kleiman NS; Adams DH; Popma JJ
    JACC Cardiovasc Interv; 2017 May; 10(10):1034-1044. PubMed ID: 28521921
    [TBL] [Abstract][Full Text] [Related]  

  • 20. 3D-printing assisted closure of paravalvular leak.
    Motwani M; Burley O; Luckie M; Cunnington C; Pisaniello AD; Hasan R; Malik I; Fraser DG
    J Cardiovasc Comput Tomogr; 2020; 14(5):e66-e68. PubMed ID: 30930181
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.