These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 3675946)

  • 1. Mechanical assistance in severe experimental cardiogenic shock.
    Moulopoulos SD; Stamatelopoulos SF; Tsoutsos DA; Saridakis NS; Economides KN; Adractas AJ
    ASAIO Trans; 1987; 33(3):212-6. PubMed ID: 3675946
    [No Abstract]   [Full Text] [Related]  

  • 2. [Problems of the mechanical cardiovascular circulation assistance using intra-aortic balloon pulsation in cardiogenic shock].
    Urbaszek W; Köhler H
    Z Gesamte Inn Med; 1972 Dec; 27(23):1025-8. PubMed ID: 4663507
    [No Abstract]   [Full Text] [Related]  

  • 3. Hemodynamic effects of a counterpulsation device implanted on the ascending aorta in severe cardiogenic shock.
    Nanas JN; Nanas SN; Charitos CE; Kontoyiannis D; Poyiadjis AD; Stamatopoulos G; Melkaoui A; Kokollis G; Moulopoulos SD
    ASAIO Trans; 1988; 34(3):229-34. PubMed ID: 3196512
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Direct mechanical ventricular assistance promotes salvage of ischemic myocardium.
    Anstadt MP; Malone JP; Brown GR; Nolan DS; Quinones JD; Anstadt GL
    ASAIO Trans; 1987; 33(3):720-5. PubMed ID: 3676009
    [No Abstract]   [Full Text] [Related]  

  • 5. Ascending aorta synchronized pulsation. A new form of circulatory assist for treatment of cardiogenic shock.
    Lang TW; Corday E; Meerbaum S; Lozano JR; Carrasco H; Gold H
    Arch Intern Med; 1971 Aug; 128(2):258-264. PubMed ID: 5564203
    [No Abstract]   [Full Text] [Related]  

  • 6. Mechanical circulatory assistance in cardiogenic shock by pressure-synchronized intra-aortic volume displacement. An experimental evaluation of the "Egaton assist device".
    Schilt W; Fourcade C; Pappova E; Lundsgaard-Hansen P
    J Cardiovasc Surg (Torino); 1971; 12(3):188-201. PubMed ID: 5091647
    [No Abstract]   [Full Text] [Related]  

  • 7. New concepts in temporary circulatory assist for treatment of cardiogenic shock.
    Lang TW; Lozano J; Carrasco H; Goldman A; Meerbaum S; Gold H; Corday E
    Geriatrics; 1971 Sep; 26(9):90-9. PubMed ID: 5125696
    [No Abstract]   [Full Text] [Related]  

  • 8. Mechanical circulatory support for cardiogenic shock.
    Subramaniam K; Boisen M; Shah PR; Ramesh V; Pete A
    Best Pract Res Clin Anaesthesiol; 2012 Jun; 26(2):131-46. PubMed ID: 22910086
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Counterpulsation in experimental cardiogenic shock with ventricular arrhythmias. The antiarrhythmic effect of morphine.
    Goiti JJ; Marquez J; Castillo-Olivares JL; Avello LF; Figuera D
    J Cardiovasc Surg (Torino); 1976; 17(1):38-42. PubMed ID: 1245504
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Use of the intra-aortic balloon pump in experimental myocardial infarct].
    Wolner E; Thoma H; Deutsch M; Enenkel W; Fasching W; Leodolter S; Navrátil J
    Z Exp Chir; 1971; 4(1):2-31. PubMed ID: 5162937
    [No Abstract]   [Full Text] [Related]  

  • 11. [Intraaortic balloon pumping--current status of IABP and artificial heart in Japan].
    Okada M; Nakamura K
    Kyobu Geka; 1986 Mar; 39(3):172-81. PubMed ID: 3517438
    [No Abstract]   [Full Text] [Related]  

  • 12. [Effects of mechanical support in cardiogenic shock, with special reference to partial pulsatile venoarterial pumping].
    Tamura M; Matsukura H; Matsuyama M; Ko S; Tamura K
    Nihon Kyobu Geka Gakkai Zasshi; 1972 Oct; 20(10):783-93. PubMed ID: 4674950
    [No Abstract]   [Full Text] [Related]  

  • 13. Intra-right-atrial balloon pumping (IRABP) during a Fontan procedure.
    Emoto H; Jacobs G; Chen JF; Nasu M; Oku T; Ishikawa M; Uchida N; Kambic H; Kasick J; Harasaki H
    ASAIO Trans; 1987; 33(3):699-703. PubMed ID: 3676005
    [No Abstract]   [Full Text] [Related]  

  • 14. [Experimental experiences and clinical aspects of mechanical blood circulation support].
    Navrátil J; Deutsch M; Wolner E
    Wien Klin Wochenschr; 1970 Oct; 82(42):731-6. PubMed ID: 5470732
    [No Abstract]   [Full Text] [Related]  

  • 15. Exercise tolerance in late survivors of balloon pumping and surgery for cardiogenic shock.
    Pierri MK; Zema M; Kligfield P; McCabe J; Hoover E; Gay W; Subramanian V
    Circulation; 1980 Aug; 62(2 Pt 2):I138-41. PubMed ID: 7397989
    [No Abstract]   [Full Text] [Related]  

  • 16. [Left ventricular assist devices in cardiogenic shock].
    Boudou N; Marcheix B; Biendel-Piquet C; Dumonteil N; Lhermusier T; Benhaoua H; Carrié D
    Ann Cardiol Angeiol (Paris); 2010 Dec; 59(6):362-6. PubMed ID: 21056404
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical use of assisted circulation.
    Pennington DG; Swartz MT
    Surg Annu; 1994; 26():169-91. PubMed ID: 8303519
    [No Abstract]   [Full Text] [Related]  

  • 18. Successful use of Impella CP® in cardiogenic shock after cardiac arrest: a first in Poland.
    Nadziakiewicz P; Zembala M; Słonka G; Balak W
    Kardiol Pol; 2017; 75(8):812. PubMed ID: 28819956
    [No Abstract]   [Full Text] [Related]  

  • 19. Phase-shift assistance with a valve balloon: experimental results.
    Tomecek J; Jaron D; Tjonneland S; Kantrowitz A
    Trans Am Soc Artif Intern Organs; 1969; 15():406-11. PubMed ID: 5791417
    [No Abstract]   [Full Text] [Related]  

  • 20. [Assisted circulation by intra-aortic counter-pulsation. Experimental study].
    Le Pailleur C; Meilhac B; Neveux JY; Mathey J; Di Matteo J
    Nouv Presse Med; 1973 Jun; 2(24):1645-9. PubMed ID: 4718069
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.