These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
176 related articles for article (PubMed ID: 36763130)
1. Dual plate has better biomechanical stability than hook plate or superior single plate for the fixation of unstable distal clavicle fractures: a finite element analysis. Huang D; Hu Z; Feng W; Wang X Arch Orthop Trauma Surg; 2023 Aug; 143(8):4805-4812. PubMed ID: 36763130 [TBL] [Abstract][Full Text] [Related]
2. Finite element analysis of dual small plate fixation and single plate fixation for treatment of midshaft clavicle fractures. Zhang F; Chen F; Qi Y; Qian Z; Ni S; Zhong Z; Zhang X; Li D; Yu B J Orthop Surg Res; 2020 Apr; 15(1):148. PubMed ID: 32295608 [TBL] [Abstract][Full Text] [Related]
3. Finite element analysis of 3 internal fixations for distal type C3 femur fractures with medial wall bone defects. Chen D; Yu J; Yu Y; Yan M Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2023 Nov; 48(11):1711-1720. PubMed ID: 38432862 [TBL] [Abstract][Full Text] [Related]
5. Biomechanical Analysis of Implanted Clavicle Hook Plates With Different Implant Depths and Materials in the Acromioclavicular Joint: A Finite Element Analysis Study. Lee CH; Shih CM; Huang KC; Chen KH; Hung LK; Su KC Artif Organs; 2016 Nov; 40(11):1062-1070. PubMed ID: 26814438 [TBL] [Abstract][Full Text] [Related]
6. Biomechanical comparison between low profile 2.7 mm distal locking hook plate and 3.5 mm distal locking hook plate for acromioclavicular joint injury: A finite element analysis. Lee JW; Song MJ; Lee SJ; Song HS; Jung YS; Kim H Injury; 2024 Oct; 55(10):111657. PubMed ID: 39002321 [TBL] [Abstract][Full Text] [Related]
7. Complications after surgical treatment of distal clavicle fractures. Singh A; Schultzel M; Fleming JF; Navarro RA Orthop Traumatol Surg Res; 2019 Sep; 105(5):853-859. PubMed ID: 31202717 [TBL] [Abstract][Full Text] [Related]
8. Biomechanical analysis of clavicle hook plate implantation with different hook angles in the acromioclavicular joint. Hung LK; Su KC; Lu WH; Lee CH Int Orthop; 2017 Aug; 41(8):1663-1669. PubMed ID: 28097386 [TBL] [Abstract][Full Text] [Related]
9. Peri-implant Fractures Following Hook Plate Fixation for Unstable Distal Clavicle Fractures. Ni PL; Lin KC; Chen CY; Tarng YW; Chang WN; Renn JH Orthopedics; 2020 Sep; 43(5):e359-e363. PubMed ID: 32602920 [TBL] [Abstract][Full Text] [Related]
10. Comparison of the use of biocompatible materials and titanium in the treatment of midshaft clavicle fractures with a patient-specific plate: a finite element analysis study. Yurteri A; Mercan N; Uğur L Arch Orthop Trauma Surg; 2024 Aug; 144(8):3255-3266. PubMed ID: 39008077 [TBL] [Abstract][Full Text] [Related]
11. Biomechanical analysis of plating techniques for unstable lateral clavicle fractures with coracoclavicular ligament disruption (Neer type IIB). Jo OI; Almond M; Rupansinghe HS; Ackland DC; Ernstbrunner L; Ek ET J Shoulder Elbow Surg; 2023 Apr; 32(4):695-702. PubMed ID: 36535559 [TBL] [Abstract][Full Text] [Related]
12. Comparison of hook plate versus T-plate in the treatment of Neer type II distal clavicle fractures: a prospective matched comparative cohort study. Teimouri M; Ravanbod H; Farrokhzad A; Sabaghi J; Mirghaderi SP J Orthop Surg Res; 2022 Jul; 17(1):369. PubMed ID: 35907856 [TBL] [Abstract][Full Text] [Related]
13. Finite element analysis comparison between superior clavicle locking plate with and without screw holes above fracture zone in midshaft clavicular fracture. Pengrung N; Lakdee N; Puncreobutr C; Lohwongwatana B; Sa-Ngasoongsong P BMC Musculoskelet Disord; 2019 Oct; 20(1):465. PubMed ID: 31640668 [TBL] [Abstract][Full Text] [Related]
14. Finite element analysis of locking plate and two types of intramedullary nails for treating mid-shaft clavicle fractures. Ni M; Niu W; Wong DW; Zeng W; Mei J; Zhang M Injury; 2016 Aug; 47(8):1618-23. PubMed ID: 27311550 [TBL] [Abstract][Full Text] [Related]
15. Finite element analysis of double-plate fixation using reversed locking compression-distal femoral plates for Vancouver B1 periprosthetic femoral fractures. Takahashi D; Noyama Y; Asano T; Shimizu T; Irie T; Terkawi MA; Iwasaki N BMC Musculoskelet Disord; 2021 Mar; 22(1):276. PubMed ID: 33714273 [TBL] [Abstract][Full Text] [Related]
16. Finite element analysis comparison of Type 42A2 fracture fixed with external titanium alloy locking plate and traditional external fixation frame. Fang S; Zhang L; Yang Y; Wang Y; Guo J; Mi L J Orthop Surg Res; 2023 Oct; 18(1):815. PubMed ID: 37907959 [TBL] [Abstract][Full Text] [Related]
17. Low-Profile Dual Small Plate Fixation Is Biomechanically Similar to Larger Superior or Anteroinferior Single Plate Fixation of Midshaft Clavicle Fractures. Ziegler CG; Aman ZS; Storaci HW; Finch H; Dornan GJ; Kennedy MI; Provencher MT; Hackett TR Am J Sports Med; 2019 Sep; 47(11):2678-2685. PubMed ID: 31381363 [TBL] [Abstract][Full Text] [Related]
18. Comparative analysis of a locking plate with an all-suture anchor versus hook plate fixation of Neer IIb distal clavicle fractures. Seo JB; Kwak KY; Yoo JS J Orthop Surg (Hong Kong); 2020; 28(3):2309499020962260. PubMed ID: 33118439 [TBL] [Abstract][Full Text] [Related]
19. Finite element analysis of different locking plate fixation methods for the treatment of ulnar head fracture. Zhang Y; Shao Q; Yang C; Ai C; Zhou D; Yu Y; Sun G J Orthop Surg Res; 2021 Mar; 16(1):191. PubMed ID: 33722253 [TBL] [Abstract][Full Text] [Related]
20. Comparison of internal fixations for distal clavicular fractures based on loading tests and finite element analyses. Sakai R; Matsuura T; Tanaka K; Uchida K; Nakao M; Mabuchi K ScientificWorldJournal; 2014; 2014():817321. PubMed ID: 25136691 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]