These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
136 related articles for article (PubMed ID: 3677419)
21. Eliminating bilirubin interference in Cobas MIRA assay of creatinine in serum. Moshkin AV Clin Chem; 1994 Aug; 40(8):1600-1. PubMed ID: 8045010 [No Abstract] [Full Text] [Related]
22. Kinetic study of the Jaffé reaction for quantifying creatinine in serum: 2. Evaluation of buffered reagent and comparison of different data-processing options. Bacon BL; Pardue HL Clin Chem; 1989 Mar; 35(3):360-3. PubMed ID: 2920402 [TBL] [Abstract][Full Text] [Related]
23. Serum creatinine determination by high performance liquid chromatography and five automated chemistry analyzers. Holmes EW; Oeser TH; Kahn SE; Bekeris L; Bermes EW Ann Clin Lab Sci; 1983; 13(6):503-10. PubMed ID: 6660833 [TBL] [Abstract][Full Text] [Related]
24. Serum ultrafiltration for the elimination of endogenous interfering substances in creatinine determination. da Fonseca-Wollheim F; Heinze KG; Lomsky K; Schreiner H J Clin Chem Clin Biochem; 1988 Aug; 26(8):523-5. PubMed ID: 3221182 [TBL] [Abstract][Full Text] [Related]
25. Does bilirubin cause interference in Roche creatinine methods? Owen LJ; Keevil BG Clin Chem; 2007 Feb; 53(2):370-1. PubMed ID: 17259257 [No Abstract] [Full Text] [Related]
26. Evaluation of bilirubin interference and accuracy of six creatinine assays compared with isotope dilution-liquid chromatography mass spectrometry. Nah H; Lee SG; Lee KS; Won JH; Kim HO; Kim JH Clin Biochem; 2016 Feb; 49(3):274-81. PubMed ID: 26519089 [TBL] [Abstract][Full Text] [Related]
27. Negligible effect of bilirubin on serum creatinine measurement by the kinetic Jaffé method. Knight DR; Trainer TD Clin Chem; 1978 Oct; 24(10):1851-2. PubMed ID: 699306 [No Abstract] [Full Text] [Related]
28. [Determination of plasma creatinine with centrifugal analyser]. Klumpp T; Férard G Ann Biol Clin (Paris); 1977; 35(3):203-8. PubMed ID: 900600 [TBL] [Abstract][Full Text] [Related]
29. Negative ketone interference with creatinine determinations on the KDA. Mori L; Jarvie T Clin Chem; 1983 Apr; 29(4):733-4. PubMed ID: 6831718 [No Abstract] [Full Text] [Related]
30. Bilirubin interference with the kinetic Jaffé method for serum creatinine. Daugherty NA; Hammond KB; Osberg IM Clin Chem; 1978 Feb; 24(2):392-3. PubMed ID: 627087 [No Abstract] [Full Text] [Related]
31. On the accuracy of the Reflotron creatinine determination. Blijenberg BG; Liesting EC; Zwang L Eur J Clin Chem Clin Biochem; 1992 Jan; 30(1):51-3. PubMed ID: 1576242 [TBL] [Abstract][Full Text] [Related]
33. A simplified procedure for eliminating the negative interference of bilirubin in the Jaffé reaction for creatinine. O'Leary N; Pembroke A; Duggan PF Clin Chem; 1992 Sep; 38(9):1749-51. PubMed ID: 1526008 [TBL] [Abstract][Full Text] [Related]
34. Effect of bilirubin covalently attached to albumin on measurement of serum creatinine. Ihara H; Nakamura H; Yoshida M; Wu TW Clin Chem; 1992 Feb; 38(2):321-2. PubMed ID: 1541028 [No Abstract] [Full Text] [Related]
35. Interference by IgG paraproteins in the Jaffe method for creatinine determination. Datta P; Graham GA; Schoen I Am J Clin Pathol; 1986 Apr; 85(4):463-8. PubMed ID: 2420168 [TBL] [Abstract][Full Text] [Related]
36. In continuous-monitored acid phosphatase methods involving diazotization, bilirubin may cause negative reaction rates. Peake M; Pejakovic M; Penberthy L Clin Chem; 1983 May; 29(5):1000-1. PubMed ID: 6839448 [No Abstract] [Full Text] [Related]
37. Comparison of creatinine as determined with the Ames Seralyzer and by three Jaffé-based methods. Kroll MH; Olson D; Rawe M; King C; Hagengruber C; Elin RJ Clin Chem; 1985 Nov; 31(11):1900-4. PubMed ID: 4053362 [TBL] [Abstract][Full Text] [Related]
38. Reference range and method comparison studies for enzymatic and Jaffé creatinine assays in plasma and serum and early morning urine. Mazzachi BC; Peake MJ; Ehrhardt V Clin Lab; 2000; 46(1-2):53-5. PubMed ID: 10745982 [No Abstract] [Full Text] [Related]
39. Evaluation of an enzymatic method for determining creatinine in plasma. Crocker H; Shephard MD; White GH J Clin Pathol; 1988 May; 41(5):576-81. PubMed ID: 3384988 [TBL] [Abstract][Full Text] [Related]
40. Interferences in current methods for measurements of creatinine. Weber JA; van Zanten AP Clin Chem; 1991 May; 37(5):695-700. PubMed ID: 2032322 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]