These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 36774785)

  • 1. An aberration correction approach for single and dual aperture ultrasound imaging of the abdomen.
    van Hal VHJ; Muller JW; van Sambeek MRHM; Lopata RGP; Schwab HM
    Ultrasonics; 2023 May; 131():106936. PubMed ID: 36774785
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fast Marching based Tissue Adaptive Delay Estimation for Aberration Corrected Delay and Sum Beamforming in Ultrasound Imaging.
    M S A; Malamal G; A N M; Melapudi V; V R; Patil A; Langoju R; Panicker MR
    Annu Int Conf IEEE Eng Med Biol Soc; 2023 Jul; 2023():1-4. PubMed ID: 38082584
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of phase aberration on transabdominal focusing for a large aperture, low
    Yeats E; Gupta D; Xu Z; Hall TL
    Phys Med Biol; 2022 Jul; 67(15):. PubMed ID: 35772383
    [No Abstract]   [Full Text] [Related]  

  • 4. On the significance of density-induced speed of sound variations on US-guided radiotherapy.
    Fontanarosa D; van der Meer S; Verhaegen F
    Med Phys; 2012 Oct; 39(10):6316-23. PubMed ID: 23039667
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Locally Adaptive Phase Aberration Correction (LAPAC) Method for Synthetic Aperture Sequences.
    Chau G; Jakovljevic M; Lavarello R; Dahl J
    Ultrason Imaging; 2019 Jan; 41(1):3-16. PubMed ID: 30222052
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improved Transcranial Plane-Wave Imaging With Learned Speed-of-Sound Maps.
    Yang Y; Duan H; Zheng Y
    IEEE Trans Med Imaging; 2024 Jun; 43(6):2191-2201. PubMed ID: 38271172
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Aperture size effect on ultrasonic wavefront distortion correction.
    Huang DH; Tsao J
    IEEE Trans Ultrason Ferroelectr Freq Control; 2004 May; 51(5):589-605. PubMed ID: 15217236
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analytical estimation of beamforming speed-of-sound using transmission geometry.
    Bezek CD; Goksel O
    Ultrasonics; 2023 Sep; 134():107069. PubMed ID: 37331051
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accelerated 2-D Real-Time Refraction-Corrected Transcranial Ultrasound Imaging.
    Mozaffarzadeh M; Verschuur DJE; Verweij MD; de Jong N; Renaud G
    IEEE Trans Ultrason Ferroelectr Freq Control; 2022 Sep; 69(9):2599-2610. PubMed ID: 35797321
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Speed-of-sound imaging using diverging waves.
    Rau R; Schweizer D; Vishnevskiy V; Goksel O
    Int J Comput Assist Radiol Surg; 2021 Jul; 16(7):1201-1211. PubMed ID: 34160749
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Deep learning for hetero-homo conversion in channel-domain for phase aberration correction in ultrasound imaging.
    Koike T; Tomii N; Watanabe Y; Azuma T; Takagi S
    Ultrasonics; 2023 Mar; 129():106890. PubMed ID: 36462461
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Combined phase screen aberration correction and minimum variance beamforming in medical ultrasound.
    Ziksari MS; Asl BM
    Ultrasonics; 2017 Mar; 75():71-79. PubMed ID: 27939788
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of phase aberration correction methods on the minimum variance beamformer.
    Chau GR; Dahl JJ; Lavarello RJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():3231-3234. PubMed ID: 28268996
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Aberration correction in diagnostic ultrasound: A review of the prior field and current directions.
    Ali R; Brevett T; Zhuang L; Bendjador H; Podkowa AS; Hsieh SS; Simson W; Sanabria SJ; Herickhoff CD; Dahl JJ
    Z Med Phys; 2023 Aug; 33(3):267-291. PubMed ID: 36849295
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Phase aberration correction for ultrasound imaging guided extracorporeal shock wave therapy (ESWT): Feasibility study.
    Kim H; Song I; Kang J; Yoo Y
    Ultrasonics; 2023 Jul; 132():107011. PubMed ID: 37071943
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Speed-of-sound compensated photoacoustic tomography for accurate imaging.
    Jose J; Willemink RG; Steenbergen W; Slump CH; van Leeuwen TG; Manohar S
    Med Phys; 2012 Dec; 39(12):7262-71. PubMed ID: 23231277
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of Phase Aberration and Phase Aberration Correction on the Minimum Variance Beamformer.
    Chau G; Dahl J; Lavarello R
    Ultrason Imaging; 2018 Jan; 40(1):15-34. PubMed ID: 28703644
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A CT based correction method for speed of sound aberration for ultrasound based image guided radiotherapy.
    Fontanarosa D; van der Meer S; Harris E; Verhaegen F
    Med Phys; 2011 May; 38(5):2665-73. PubMed ID: 21776803
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Robust Method for Ultrasound Beamforming in the Presence of Off-Axis Clutter and Sound Speed Variation.
    Dei K; Byram B
    Ultrasonics; 2018 Sep; 89():34-45. PubMed ID: 29723842
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Distributed Aberration Correction Techniques Based on Tomographic Sound Speed Estimates.
    Ali R; Brevett T; Hyun D; Brickson LL; Dahl JJ
    IEEE Trans Ultrason Ferroelectr Freq Control; 2022 May; 69(5):1714-1726. PubMed ID: 35353699
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.