150 related articles for article (PubMed ID: 36778833)
1. Relationship between pulse pressure variation and stroke volume variation with changes in cardiac index during hypotension in patients undergoing major spine surgeries in prone position - A prospective observational study.
Arumugam R; Thomas S; Jacob NSM; Nadaraj A; George SP; Singh G
J Anaesthesiol Clin Pharmacol; 2022; 38(4):553-559. PubMed ID: 36778833
[TBL] [Abstract][Full Text] [Related]
2. Effects of stroke volume variation, pulse pressure variation, and pleth variability index in predicting fluid responsiveness during different positive end expiratory pressure in prone position.
Chen Y; Fu Q; Mi WD
Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2015 Apr; 37(2):179-84. PubMed ID: 25936706
[TBL] [Abstract][Full Text] [Related]
3. Assessment of Fluid Responsiveness in Prone Neurosurgical Patients Undergoing Protective Ventilation: Role of Dynamic Indices, Tidal Volume Challenge, and End-Expiratory Occlusion Test.
Messina A; Montagnini C; Cammarota G; Giuliani F; Muratore L; Baggiani M; Bennett V; Della Corte F; Navalesi P; Cecconi M
Anesth Analg; 2020 Mar; 130(3):752-761. PubMed ID: 31651455
[TBL] [Abstract][Full Text] [Related]
4. [Stroke volume and pulse pressure variation are good predictors of fluid responsiveness in sepsis patients].
Drvar Z; Pavlek M; Drvar V; Tomasević B; Baronica R; Perić M
Acta Med Croatica; 2013 Dec; 67(5):407-14. PubMed ID: 24979881
[TBL] [Abstract][Full Text] [Related]
5. Hemodynamic changes in the prone position according to fluid loading after anaesthesia induction in patients undergoing lumbar spine surgery: a randomized, assessor-blind, prospective study.
Lee S; Kim DY; Han J; Kim K; You AH; Kang HY; Park SW; Kim MK; Kim JE; Choi JH
Ann Med; 2024 Dec; 56(1):2356645. PubMed ID: 38794845
[TBL] [Abstract][Full Text] [Related]
6. Accuracy of stroke volume variation and pulse pressure variation to predict fluid responsiveness in patients with thoracic kyphosis.
Chen Y; Guo X; Fu J; Dong T; Liu X; Lv H
Ann Palliat Med; 2021 Jul; 10(7):7571-7578. PubMed ID: 34154341
[TBL] [Abstract][Full Text] [Related]
7. Validity of Pulse Pressure Variation (PPV) Compared with Stroke Volume Variation (SVV) in Predicting Fluid Responsiveness.
Rathore A; Singh S; Lamsal R; Taank P; Paul D
Turk J Anaesthesiol Reanim; 2017 Aug; 45(4):210-217. PubMed ID: 28868168
[TBL] [Abstract][Full Text] [Related]
8. The tidal volume challenge improves the reliability of dynamic preload indices during robot-assisted laparoscopic surgery in the Trendelenburg position with lung-protective ventilation.
Jun JH; Chung RK; Baik HJ; Chung MH; Hyeon JS; Lee YG; Park SH
BMC Anesthesiol; 2019 Aug; 19(1):142. PubMed ID: 31390982
[TBL] [Abstract][Full Text] [Related]
9. [Comparison of pulse pressure variation, stroke volume variation, and plethysmographic variability index in pediatric patients undergoing craniotomy].
Liu YF; Song LL; Xing MW; Cai LX; Wang DX
Beijing Da Xue Xue Bao Yi Xue Ban; 2021 Oct; 53(5):946-951. PubMed ID: 34650300
[TBL] [Abstract][Full Text] [Related]
10. Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor.
Stens J; Oeben J; Van Dusseldorp AA; Boer C
J Clin Monit Comput; 2016 Oct; 30(5):587-94. PubMed ID: 26318314
[TBL] [Abstract][Full Text] [Related]
11. Predictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum.
Zlicar M; Novak-Jankovic V; Blagus R; Cecconi M
J Clin Monit Comput; 2018 Oct; 32(5):825-832. PubMed ID: 29149433
[TBL] [Abstract][Full Text] [Related]
12. Utility of stroke volume variation measured using non-invasive bioreactance as a predictor of fluid responsiveness in the prone position.
Min JJ; Lee JH; Hong KY; Choi SJ
J Clin Monit Comput; 2017 Apr; 31(2):397-405. PubMed ID: 26964992
[TBL] [Abstract][Full Text] [Related]
13. Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery.
Biais M; Bernard O; Ha JC; Degryse C; Sztark F
Br J Anaesth; 2010 Apr; 104(4):407-13. PubMed ID: 20190260
[TBL] [Abstract][Full Text] [Related]
14. Predicting stroke volume and arterial pressure fluid responsiveness in liver cirrhosis patients using dynamic preload variables: A prospective study of diagnostic accuracy.
Wu CY; Cheng YJ; Liu YJ; Wu TT; Chien CT; Chan KC;
Eur J Anaesthesiol; 2016 Sep; 33(9):645-52. PubMed ID: 27167058
[TBL] [Abstract][Full Text] [Related]
15. Dynamic Arterial Elastance as a Predictor of Supine-to-Prone Hypotension (SuProne Study): An Observational Study.
Ahn JH; Park J; Shim JG; Lee SH; Ryu KH; Jeong T; Cho EA
Medicina (Kaunas); 2023 Nov; 59(12):. PubMed ID: 38138152
[No Abstract] [Full Text] [Related]
16. Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting.
Hofer CK; Müller SM; Furrer L; Klaghofer R; Genoni M; Zollinger A
Chest; 2005 Aug; 128(2):848-54. PubMed ID: 16100177
[TBL] [Abstract][Full Text] [Related]
17. Pulse pressure variation and stroke volume variation to predict fluid responsiveness in patients undergoing carotid endarterectomy.
Kim KM; Gwak MS; Choi SJ; Kim MH; Park MH; Heo BY
Korean J Anesthesiol; 2013 Sep; 65(3):237-43. PubMed ID: 24101958
[TBL] [Abstract][Full Text] [Related]
18. Limitations of arterial pulse pressure variation and left ventricular stroke volume variation in estimating cardiac pre-load during open heart surgery.
Rex S; Schälte G; Schroth S; de Waal EE; Metzelder S; Overbeck Y; Rossaint R; Buhre W
Acta Anaesthesiol Scand; 2007 Oct; 51(9):1258-67. PubMed ID: 17714575
[TBL] [Abstract][Full Text] [Related]
19. Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression.
Messina A; Caporale M; Calabrò L; Lionetti G; Bono D; Matronola GM; Brunati A; Frassanito L; Morenghi E; Antonelli M; Chew MS; Cecconi M
Crit Care; 2023 Nov; 27(1):431. PubMed ID: 37940953
[TBL] [Abstract][Full Text] [Related]
20. Automated stroke volume and pulse pressure variations predict fluid responsiveness in mechanically ventilated patients with obstructive jaundice.
Zhao F; Wang P; Pei S; Mi W; Fu Q
Int J Clin Exp Med; 2015; 8(11):20751-9. PubMed ID: 26884998
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]