These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 36793295)

  • 21. Study of Coating Growth Direction of 6061 Aluminum Alloy in Soft Spark Discharge of Plasma Electrolytic Oxidation.
    Wang W; Yang Y; Liu C; Chen B; Chen X; Wang H; Tong R; Zhou S
    Materials (Basel); 2024 Jun; 17(12):. PubMed ID: 38930316
    [TBL] [Abstract][Full Text] [Related]  

  • 22. MC3T3-E1 cell response of amorphous phase/TiO2 nanocrystal composite coating prepared by microarc oxidation on titanium.
    Zhou R; Wei D; Yang H; Feng W; Cheng S; Li B; Wang Y; Jia D; Zhou Y
    Mater Sci Eng C Mater Biol Appl; 2014 Jun; 39():186-95. PubMed ID: 24863215
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effect of zinc content on the microstructure, in vitro bioactivity, and corrosion behavior of the microarc oxidized Mg-xZn-0.6Ca (x = 3.0, 4.5, 6.0) alloy.
    Wang J; Pan Y; Wang W; Cui H; Feng R; Cui X; Gong B; Zhao X; Hou N
    Biointerphases; 2021 Feb; 16(1):011007. PubMed ID: 33706520
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Characteristic and in vitro bioactivity of a microarc-oxidized TiO(2)-based coating after chemical treatment.
    Wei D; Zhou Y; Jia D; Wang Y
    Acta Biomater; 2007 Sep; 3(5):817-27. PubMed ID: 17478133
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Polyethylenimine/kappa carrageenan: Micro-arc oxidation coating for passivation of magnesium alloy.
    Golshirazi A; Kharaziha M; Golozar MA
    Carbohydr Polym; 2017 Jul; 167():185-195. PubMed ID: 28433153
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The in vitro and in vivo performance of a strontium-containing coating on the low-modulus Ti35Nb2Ta3Zr alloy formed by micro-arc oxidation.
    Liu W; Cheng M; Wahafu T; Zhao Y; Qin H; Wang J; Zhang X; Wang L
    J Mater Sci Mater Med; 2015 Jul; 26(7):203. PubMed ID: 26152510
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Anti-corrosion of amphoteric metal enhanced by MAO/corrosion inhibitor composite in acid, alkaline and salt solutions.
    Sun W; Liu Y; Li T; Cui S; Chen S; Yu Q; Wang D
    J Colloid Interface Sci; 2019 Oct; 554():488-499. PubMed ID: 31326782
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effect of calcium on the microstructure and corrosion behavior of microarc oxidized Mg-xCa alloys.
    Pan Y; Chen C; Feng R; Cui H; Gong B; Zheng T; Ji Y
    Biointerphases; 2018 Jan; 13(1):011003. PubMed ID: 29338270
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Structure and Infrared Emissivity Properties of the MAO Coatings Formed on TC4 Alloys in K₂ZrF₆-Based Solution.
    Gao G; Li Y; Hu D; Xi Z
    Materials (Basel); 2018 Feb; 11(2):. PubMed ID: 29414841
    [TBL] [Abstract][Full Text] [Related]  

  • 30. In vitro degradation and electrochemical corrosion evaluations of microarc oxidized pure Mg, Mg-Ca and Mg-Ca-Zn alloys for biomedical applications.
    Pan Y; He S; Wang D; Huang D; Zheng T; Wang S; Dong P; Chen C
    Mater Sci Eng C Mater Biol Appl; 2015 Feb; 47():85-96. PubMed ID: 25492176
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of current density on the microstructure and corrosion resistance of microarc oxidized ZK60 magnesium alloy.
    You Q; Yu H; Wang H; Pan Y; Chen C
    Biointerphases; 2014 Sep; 9(3):031009. PubMed ID: 25280850
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The Otto Aufranc Award: enhanced biocompatibility of stainless steel implants by titanium coating and microarc oxidation.
    Lim YW; Kwon SY; Sun DH; Kim YS
    Clin Orthop Relat Res; 2011 Feb; 469(2):330-8. PubMed ID: 20936386
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The effect of NaOH concentration on the steam-hydrothermally treated bioactive microarc oxidation coatings containing Ca, P, Si and Na on pure Ti surface.
    Zhou R; Wei D; Cao J; Feng W; Cheng S; Du Q; Li B; Wang Y; Jia D; Zhou Y
    Mater Sci Eng C Mater Biol Appl; 2015 Apr; 49():669-680. PubMed ID: 25686996
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Corrosion behaviour of micro-arc oxidation coatings on Mg-2Sr prepared in poly(ethylene glycol)-incorporated electrolytes.
    Gao D; Dou J; Hu C; Yu H; Chen C
    RSC Adv; 2018 Jan; 8(7):3846-3857. PubMed ID: 35542914
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Coating Formation on Ti-6Al-4V Alloy by Micro Arc Oxidation in Molten Salt.
    Sobolev A; Wolicki I; Kossenko A; Zinigrad M; Borodianskiy K
    Materials (Basel); 2018 Sep; 11(9):. PubMed ID: 30181496
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Corrosion Resistance of the GO/ZIF-8 Hybrid Loading Benzotriazole as a Multifunctional Composite Filler-Modified MgAlY Layered Double Hydroxide Coating.
    Wu L; Chen Y; Dai X; Yao W; Wu J; Xie Z; Jiang B; Yuan Y; Pan F
    Langmuir; 2022 Aug; 38(33):10338-10350. PubMed ID: 35944160
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effects of K
    Xie X; Yang E; Zhang Z; Wei W; Li D; Zhao X; Yang R; Li W
    Materials (Basel); 2023 Feb; 16(5):. PubMed ID: 36902945
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Corrosion Inhibitor-Modified Plasma Electrolytic Oxidation Coatings on 6061 Aluminum Alloy.
    Sowa M; Wala M; Blacha-Grzechnik A; Maciej A; Kazek-Kęsik A; Stolarczyk A; Simka W
    Materials (Basel); 2021 Jan; 14(3):. PubMed ID: 33572836
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Construction of lubricant composite coating on Ti6Al4V alloy using micro-arc oxidation and grafting hydrophilic polymer.
    Wang K; Xiong D
    Mater Sci Eng C Mater Biol Appl; 2018 Sep; 90():219-226. PubMed ID: 29853085
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Structure, cell response and biomimetic apatite induction of gradient TiO2-based/nano-scale hydrophilic amorphous titanium oxide containing Ca composite coatings before and after crystallization.
    Wei D; Zhou Y; Yang C
    Colloids Surf B Biointerfaces; 2009 Nov; 74(1):230-7. PubMed ID: 19683901
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.