These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
124 related articles for article (PubMed ID: 367947)
1. Automated computation of cardiac output and shunts from indicator dilution curves. Krovetz LJ IEEE Trans Biomed Eng; 1979 Feb; 26(2):117-9. PubMed ID: 367947 [No Abstract] [Full Text] [Related]
2. Noninvasive cardiopulmonary monitoring. San Filippo JA; Cohn J; Gupte P; Barbato J; Feldman M; Del Guercio LR Surgery; 1981 Aug; 90(2):313-8. PubMed ID: 7020138 [TBL] [Abstract][Full Text] [Related]
3. Estimation of systemic blood flow by the indicator-dilution technic in the presence of central shunts. Friedman PJ; Downing SE Am J Cardiol; 1968 Nov; 22(5):672-7. PubMed ID: 4879035 [No Abstract] [Full Text] [Related]
4. A CARDIAC OUTPUT COMPUTER FOR THE RAPID ANALYSIS OF INDICATOR-DILUTION CURVES. MOODY NF; BARBER HD; HOLMLUND BA; MERRIMAN JE IEEE Trans Biomed Eng; 1963 Jan; 10():16-23. PubMed ID: 14059524 [No Abstract] [Full Text] [Related]
5. Volume of interatrial shunt; studies with selective dilution curves (left-to-right shunts). Kraszewski W; Kruk E Mater Med Pol; 1979; 11(3):248-52. PubMed ID: 398433 [No Abstract] [Full Text] [Related]
6. Loss of diffusible indicator in the pulmonary vascular circuit. Grubbs DS; Geddes LA; Kuzmic J Jpn Heart J; 1984 Nov; 25(6):1047-50. PubMed ID: 6397601 [TBL] [Abstract][Full Text] [Related]
7. A fully automated cardiac output analysis system. Cohn JD; Marko AR Med Instrum; 1975; 9(2):93-8. PubMed ID: 1092970 [TBL] [Abstract][Full Text] [Related]
8. Automated procedures for indicator-dilution curves using a digital computer. Anand DK; De Pian L Biomed Instrum; 1964 Dec; 1(3):21-4. PubMed ID: 5878104 [No Abstract] [Full Text] [Related]
9. Proceedings: Computer-facilitated measurements from cardiac output indicator dilution curves. Simons RS; White Y Br J Anaesth; 1976 Mar; 48(3):275-6. PubMed ID: 769813 [No Abstract] [Full Text] [Related]
10. The dispersion of indicator in the cardio-pulmonary system. Norwich KH; Zelin S Bull Math Biophys; 1970 Mar; 32(1):25-43. PubMed ID: 4907348 [No Abstract] [Full Text] [Related]
11. Flow estimation by indicator dilution (bolus injection). Bassingthwaighte JB; Knopp TJ; Anderson DU Circ Res; 1970 Aug; 27(2):277-91. PubMed ID: 4917088 [TBL] [Abstract][Full Text] [Related]
12. Studies on indicator dilution curves using mathematical modelling and digital computer techniques. Sekelj P Med Biol Eng; 1973 Jul; 11(4):436-46. PubMed ID: 4580779 [No Abstract] [Full Text] [Related]
13. [Indicator methods in circulatory diagnosis. A comparison among dye dilution, thermodilution and radiodensitometry]. Rutishauser W Schweiz Med Wochenschr; 1967 Mar; 97(11):340-7. PubMed ID: 4875572 [No Abstract] [Full Text] [Related]
14. Limitations of thermal dilution curves for cardiac output determinations. Wessel HU; Paul MH; James GW; Grahn AR J Appl Physiol; 1971 May; 30(5):643-52. PubMed ID: 4929471 [No Abstract] [Full Text] [Related]
15. Analog computer analysis of dilution curves recorded by scintillation camera: measurements of cardiac chamber and pulmonary volumes and left to right shunts. Konishi Y Nihon Geka Hokan; 1974 Jan; 43(1):3-34. PubMed ID: 4603138 [No Abstract] [Full Text] [Related]
16. RAPID METHOD FOR DETERMINATION OF CARDIAC OUTPUT BY INDICATOR DILUTION TECHNIQUES. BOYETT JD; STOWE DE; BECKER LH; BRITZ WE J Lab Clin Med; 1964 Jul; 64():160-7. PubMed ID: 14192562 [No Abstract] [Full Text] [Related]
17. An algorithm for the automated determination of cardiac output by the Stewart-Hamilton method. Francis DB; Hu KC IEEE Trans Biomed Eng; 1977 Sep; 24(5):482-4. PubMed ID: 330388 [No Abstract] [Full Text] [Related]
18. Rapid assessment of cardiac output and central blood volumes from indicator dilution curves without precalculation using programmable calculators. Cole MA; Crawford DW Comput Programs Biomed; 1980 Apr; 11(2):105-12. PubMed ID: 6993093 [TBL] [Abstract][Full Text] [Related]
19. [The thermodilution technic: preliminary results in the measurement of blood flow]. Warembourg H; Houdas Y; Delomez M; Bertrand M; Ketelers JY Arch Mal Coeur Vaiss; 1968 Oct; 61(10):1401-13. PubMed ID: 4974049 [No Abstract] [Full Text] [Related]
20. Shunt quantification by mathematical analysis of indicator dilution curves. Billings RG; Clark JS; Veasy LG; Cutler CA Cathet Cardiovasc Diagn; 1978; 4(2):143-62. PubMed ID: 352532 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]