These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 36794802)

  • 1. Novel use of an autologous scleral button graft to close the anterior defect in evisceration surgery.
    Bapty J; Schulz CB; Makuloluwe S; MacLean H
    Orbit; 2023 Dec; 42(6):579-586. PubMed ID: 36794802
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evisceration with autogenous scleral graft and bioceramic implantation within the modified scleral shell: 133 cases over 17 years.
    Nadal J; Daien V; Jacques J; Hoa D; Mura F; Villain M
    Orbit; 2019 Feb; 38(1):19-23. PubMed ID: 29672208
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Single or double? A comparison of evisceration techniques.
    Lai KKH; Kuk AKT; Au AKH; Wong KKH; Wang T; Tsang A; Tai JHT; Ong THL; Ko STC; Chan E; Ko CKL
    Int Ophthalmol; 2023 Jun; 43(6):1811-1817. PubMed ID: 36482132
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Anterior surface breakdown and implant extrusion following secondary alloplastic orbital implantation surgery.
    Axmann S; Paridaens D
    Acta Ophthalmol; 2018 May; 96(3):310-313. PubMed ID: 29220117
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evisceration With Implant Placement Posterior to Posterior Sclera.
    Jordan DR; Stoica B
    Ophthalmic Plast Reconstr Surg; 2016; 32(3):178-82. PubMed ID: 25811165
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Retroscleral implantation technique for porous polyethylene orbital implant after evisceration.
    Choung HK; Han SK; Khwarg SI
    Ophthalmic Surg Lasers Imaging; 2005; 36(5):436-40. PubMed ID: 16238047
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Autologous dermis graft at the time of evisceration or enucleation.
    Vagefi MR; McMullan TF; Burroughs JR; Isaacs DK; Tsirbas A; White GL; Anderson RL; McCann JD
    Br J Ophthalmol; 2007 Nov; 91(11):1528-31. PubMed ID: 17947269
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The use of autologous dermis grafts for the reconstruction of the anophthalmic socket.
    Bengoa-González A; Dolores Lago-Llinás M; Martín-Clavijo A; Ling-Tan S
    Orbit; 2010 Aug; 29(4):183-9. PubMed ID: 20812833
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Enucleation with reverse replacement of sclera as an alternative to conventional evisceration.
    Madill S; Maclean H
    Orbit; 2005 Mar; 24(1):23-8. PubMed ID: 15764112
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Integrated versus non-integrated orbital implants for treating anophthalmic sockets.
    Schellini S; El Dib R; Silva LR; Farat JG; Zhang Y; Jorge EC
    Cochrane Database Syst Rev; 2016 Nov; 11(11):CD010293. PubMed ID: 27820878
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Anterior vestibule salvaging technique to limit silicone orbital implant extrusion following evisceration.
    Moore NA; Fu R; Clark J; Prendes M; Nunery WR; Burgett RA; Lee HBH
    Orbit; 2019 Aug; 38(4):318-321. PubMed ID: 30388918
    [No Abstract]   [Full Text] [Related]  

  • 12. A modified evisceration technique with scleral quadrisection and porous polyethylene implantation.
    Huang D; Yu Y; Lu R; Yang H; Cai J
    Am J Ophthalmol; 2009 May; 147(5):924-8, 928.e1-3. PubMed ID: 19211096
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Secondary orbital ball implants after enucleation and evisceration: surgical management, morbidity, and long-term outcome.
    Quaranta-Leoni FM; Sposato S; Lorenzano D
    Ophthalmic Plast Reconstr Surg; 2015; 31(2):115-8. PubMed ID: 25025388
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of Three Different Techniques on the Movement of Implants After Evisceration.
    Sendul SY; Mavi Yildiz A; Dirim B; Kacar H; Yildiz AA; Demir AG; Karapapak M; Guven D
    J Craniofac Surg; 2019 Oct; 30(7):e590-e593. PubMed ID: 31157636
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Anterior surface breakdown following evisceration : "Classic", "scleral modification", and "scleral patch techniques"].
    Vijlbrief JW; Hafezi F; Paridaens D
    Ophthalmologe; 2010 Mar; 107(3):246-50. PubMed ID: 19578857
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evisceration with scleral modification.
    Massry GG; Holds JB
    Ophthalmic Plast Reconstr Surg; 2001 Jan; 17(1):42-7. PubMed ID: 11206744
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evisceration: a new technique of trans-scleral implant placement.
    Long JA; Tann TM; Girkin CA
    Ophthalmic Plast Reconstr Surg; 2000 Sep; 16(5):322-5. PubMed ID: 11021379
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Remove, rotate, and reimplant: a novel technique for the management of exposed porous anophthalmic implants in eviscerated patients.
    Kaynak P; Karabulut GO; Ozturker C; Perente I; Gökyiǧit B; Demirok A; Yilmaz OF
    Eye (Lond); 2014 May; 28(5):546-52. PubMed ID: 24503727
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Four petal evisceration versus standard technique: A retrospective study.
    Ranno S; Serafino M; Nucci P
    Eur J Ophthalmol; 2021 Jul; 31(4):2156-2159. PubMed ID: 32799549
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Scleral shield: primary results of a new surgical technique in augmenting porous orbital implant protection.
    Gawdat TI; Ahmed RA
    Eur J Ophthalmol; 2014; 24(6):948-52. PubMed ID: 24729142
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.