BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 36795403)

  • 1. Validation of the Aktiia blood pressure cuff for clinical use according to the ANSI/AAMI/ISO 81060-2:2013 protocol.
    Alexandre J; Tan K; Almeida TP; Sola J; Alpert BS; Shah J
    Blood Press Monit; 2023 Apr; 28(2):109-112. PubMed ID: 36795403
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of the Withings BPM Connect Device for Self-Blood Pressure Measurements in General Population - Validation According to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
    Topouchian J; Zelveian P; Hakobyan Z; Gharibyan H; Asmar R
    Vasc Health Risk Manag; 2022; 18():191-200. PubMed ID: 35386428
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation of Omron HEM-7600T, a wearable device for monitoring blood pressure, according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2:2013 protocol in the general population without arrhythmias.
    Takahashi H; Saito K; Hishiki Y
    Blood Press Monit; 2021 Apr; 26(2):156-159. PubMed ID: 33577185
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Validation of the Microlife BP B3 AFIB upper arm blood pressure monitor in adults and adolescents according to the ANSI/AAMI/ISO 81060-2:2019 protocol.
    Beime B; Bramlage C; Krüger R; Deutsch C; van Mark G; Bramlage P; Botta B
    Blood Press Monit; 2021 Aug; 26(4):299-304. PubMed ID: 33734119
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Validation of the Withings BPM Core Device for Self-Blood Pressure Measurements in General Population According to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
    Hakobyan Z; Zelveian P; Topouchian J; Hazarapetyan L; Asmar R
    Vasc Health Risk Manag; 2023; 19():391-398. PubMed ID: 37426327
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of the COMBEI BP118A Device for Self-Blood Pressure Measurements in General Population - Validation According to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
    Tasić N; Topouchian J; Tasic D; Kovacevic Z; Filipovic M; Asmar R
    Vasc Health Risk Manag; 2022; 18():123-129. PubMed ID: 35309162
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation of a smartphone auscultatory blood pressure kit Accutension XYZ-110 in adults according to the ANSI/AAMI/ISO 81060-2: 2013 standard.
    Chu G; Zhang Z; Xu M; Huang D; Dai Q
    Blood Press Monit; 2017 Oct; 22(5):290-294. PubMed ID: 28505014
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Validation of Omron HEM-9200T, a home blood pressure monitoring device for the upper arm, according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2:2013 protocol.
    Takahashi H; Saito K; Yakura N
    J Hum Hypertens; 2022 Apr; 36(4):416-419. PubMed ID: 33837291
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Validation of the JOYTECH DBP-6279B blood pressure monitor in adults and adolescents according to the AAMI/ESH/ISO universal standard(ISO 81060-2:2018 + Amd.1:2020).
    Duan B; He L; Zhang J; Fang L; Li G
    Blood Press Monit; 2023 Oct; 28(5):284-288. PubMed ID: 37434533
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation of the AViTA BPM636 upper arm blood pressure monitor in adults and pregnant women according to the ANSI/AAMI/ISO 81060-2:2013.
    Lee CN; Wu CK; Huang IC
    Blood Press Monit; 2023 Aug; 28(4):215-220. PubMed ID: 37074406
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Validation of the Omron HBP-1320 for professional use according to the ANSI/AAMI/ISO 81060-2: 2013 protocol and the 2010 revision of the European Society of Hypertension International Protocol.
    Saito K; Hishiki Y; Takahashi H
    Blood Press Monit; 2020 Jun; 25(3):162-166. PubMed ID: 32118675
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Validation of the KANG KC-2850 oscillometric upper-arm ambulatory blood pressure monitor in general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization universal standard.
    Liu K; Ma YF; Wang Y; Zhang Y; Li LY; Zhang JQ; Jiang J; Chen RL; Wan Y
    Blood Press Monit; 2022 Oct; 27(5):349-352. PubMed ID: 35687039
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Validation of the Omron HBP-9031C professional office blood pressure monitor in the general population according to the ANSI/AAMI/ISO 81060-2:2013 protocol.
    Saito K; Hishiki Y; Takahashi H
    J Hum Hypertens; 2020 Oct; 34(10):735-738. PubMed ID: 31969675
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Blood pressure from the optical Aktiia Bracelet: a 1-month validation study using an extended ISO81060-2 protocol adapted for a cuffless wrist device.
    Vybornova A; Polychronopoulou E; Wurzner-Ghajarzadeh A; Fallet S; Sola J; Wuerzner G
    Blood Press Monit; 2021 Aug; 26(4):305-311. PubMed ID: 33675592
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Validation of the YuWell YE680B upper-arm blood pressure monitor in adults according to the ANSI/AAMI/ISO 81060-2: 2013 standard.
    Huang JF; Zhang W; Li Y; Wang JG
    Blood Press Monit; 2019 Dec; 24(6):315-318. PubMed ID: 31577550
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Validation of the JAMR F1701T (arm type) pressure monitor according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/ISO 81060-2:2018 protocol.
    Li J; Han LH; Feng R; Wu LH; Cai J; Zeng TY; Liu H; Zeng YW; Zhou L; Zhan ZQ
    Blood Press Monit; 2023 Jun; 28(3):163-166. PubMed ID: 37016972
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Validation of the oscillometric home blood pressure monitor Braun BUA4000 with wide-range cuff in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard.
    Ntousopoulos V; Ntineri A; Theodosiadi A; Stathopoulou P; Menti A; Kyriakoulis KG; Kollias A; Stergiou GS
    Blood Press Monit; 2024 Apr; 29(2):99-102. PubMed ID: 37997431
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Validation of the automated oscillometric upper-arm cuff home blood pressure monitor AVITA BPM82 in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard.
    Menti A; Ntousopoulos V; Theodosiadi A; Stathopoulou P; Kollias A; Stergiou GS
    Blood Press Monit; 2024 Apr; 29(2):89-92. PubMed ID: 37937605
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of the DBP-1333b upper-arm blood pressure monitor according to the AAMI/ESH/ISO universal standard (ISO 81060-2:2018+Amd.1:2020).
    Hou G; Wu Y; Wang J; Zhi J
    Blood Press Monit; 2024 Jun; 29(3):149-155. PubMed ID: 38193368
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Validation of the Microlife BP A3 PC upper arm blood pressure monitor in patients with diabetes mellitus according to the ANSI/AAMI/ISO 81060-2: 2013 protocol.
    Beime B; Krüger R; Hammel G; Bramlage P; Deutsch C
    Blood Press Monit; 2018 Feb; 23(1):52-57. PubMed ID: 29140801
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.