133 related articles for article (PubMed ID: 36801144)
1. Exploring digital technologies used in the design and manufacture of craniofacial implant surgical guides: A scoping review.
Salem D; Reher P; Evans JL; Mansour MH
J Prosthet Dent; 2024 Jun; 131(6):1264-1270. PubMed ID: 36801144
[TBL] [Abstract][Full Text] [Related]
2. Digitally designed surgical guides for placing extraoral implants in the mastoid area.
Van der Meer WJ; Vissink A; Raghoebar GM; Visser A
Int J Oral Maxillofac Implants; 2012; 27(3):703-7. PubMed ID: 22616066
[TBL] [Abstract][Full Text] [Related]
3. Systematic Review of Clinical Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Orbital Prostheses.
Tanveer W; Ridwan-Pramana A; Molinero-Mourelle P; Forouzanfar T
Int J Environ Res Public Health; 2021 Oct; 18(21):. PubMed ID: 34769865
[TBL] [Abstract][Full Text] [Related]
4. Accuracy of implant placement using CAD-CAM tooth-supported surgical guides for an auricular prosthesis in vitro.
Fan Y; Wei H; Zhao R; Lin X; Bai S
J Prosthodont; 2024 Jan; 33(1):70-76. PubMed ID: 36710294
[TBL] [Abstract][Full Text] [Related]
5. Systematic Review of Clinical Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Nasal Prostheses.
Tanveer W; Ridwan-Pramana A; Molinero-Mourelle P; Koolstra JH; Forouzanfar T
Int J Environ Res Public Health; 2021 Apr; 18(7):. PubMed ID: 33916853
[TBL] [Abstract][Full Text] [Related]
6. Computer-aided design and manufacturing construction of a surgical template for craniofacial implant positioning to support a definitive nasal prosthesis.
Ciocca L; Fantini M; De Crescenzio F; Persiani F; Scotti R
Clin Oral Implants Res; 2011 Aug; 22(8):850-6. PubMed ID: 21198902
[TBL] [Abstract][Full Text] [Related]
7. A digital approach integrating facial scanning in a CAD-CAM workflow for complete-mouth implant-supported rehabilitation of patients with edentulism: A pilot clinical study.
Hassan B; Gimenez Gonzalez B; Tahmaseb A; Greven M; Wismeijer D
J Prosthet Dent; 2017 Apr; 117(4):486-492. PubMed ID: 27881321
[TBL] [Abstract][Full Text] [Related]
8. Patient-Specific Implant in Prosthetic Craniofacial Reconstruction: First Report of a Novel Technique With Far-Reaching Perspective.
Toso SM; Menzel K; Motzkus Y; Adolphs N; Hoffmeister B; Raguse JD
J Craniofac Surg; 2015 Oct; 26(7):2133-5. PubMed ID: 26468797
[TBL] [Abstract][Full Text] [Related]
9. Split-mouth comparison of the accuracy of computer-generated and conventional surgical guides.
Farley NE; Kennedy K; McGlumphy EA; Clelland NL
Int J Oral Maxillofac Implants; 2013; 28(2):563-72. PubMed ID: 23527361
[TBL] [Abstract][Full Text] [Related]
10. CAD/CAM Beyond Intraoral Restorations: Maxillofacial Implant Guide.
Machado V; Bettoni Cruz de Castro F; Jaeger C; Rodrigues Alfenas E; Silva NRFA
Compend Contin Educ Dent; 2019; 40(7):466-472. PubMed ID: 31478691
[TBL] [Abstract][Full Text] [Related]
11. Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Auricular Prostheses-Systematic Review.
Tanveer W; Ridwan-Pramana A; Molinero-Mourelle P; Forouzanfar T
J Clin Med; 2023 Sep; 12(18):. PubMed ID: 37762891
[TBL] [Abstract][Full Text] [Related]
12. Rehabilitation of a dentate mandible requiring a full arch rehabilitation. Immediate loading of a fixed complete denture on 8 implants placed with a bone-supported surgical computer-planned guide: a case report.
Amorfini L; Storelli S; Romeo E
J Oral Implantol; 2011 Mar; 37 Spec No():106-13. PubMed ID: 21495798
[TBL] [Abstract][Full Text] [Related]
13. Advantages and limitations of implant surgery with CAD/CAM surgical guides: A literature review.
Unsal GS; Turkyilmaz I; Lakhia S
J Clin Exp Dent; 2020 Apr; 12(4):e409-e417. PubMed ID: 32382391
[TBL] [Abstract][Full Text] [Related]
14. In Vivo Accuracy of Implant Placement Using a Full Digital Planning Modality and Stereolithographic Guides.
Skjerven H; Riis UH; Herlofsson BB; Ellingsen JE
Int J Oral Maxillofac Implants; 2019; 34(1):124-132. PubMed ID: 30695088
[TBL] [Abstract][Full Text] [Related]
15. Computer-aided design and computer-aided modeling (CAD/CAM) generated surgical splints, cutting guides and custom-made implants: Which indications in orthognathic surgery?
Scolozzi P
Rev Stomatol Chir Maxillofac Chir Orale; 2015 Dec; 116(6):343-9. PubMed ID: 26598243
[TBL] [Abstract][Full Text] [Related]
16. CAD-CAM construction of an auricular template for craniofacial implant positioning: a novel approach to diagnosis.
Ciocca L; Mingucci R; Bacci G; Scotti R
Eur J Radiol; 2009 Aug; 71(2):253-6. PubMed ID: 18562144
[TBL] [Abstract][Full Text] [Related]
17. Integration of digital technology in the workflow for an osseointegrated implant-retained nasal prosthesis: A clinical report.
McHutchion L; Kincade C; Wolfaardt J
J Prosthet Dent; 2019 May; 121(5):858-862. PubMed ID: 30782455
[TBL] [Abstract][Full Text] [Related]
18. Computer-aided design and computer-aided manufacturing cutting guides and customized titanium plates are useful in upper maxilla waferless repositioning.
Mazzoni S; Bianchi A; Schiariti G; Badiali G; Marchetti C
J Oral Maxillofac Surg; 2015 Apr; 73(4):701-7. PubMed ID: 25622881
[TBL] [Abstract][Full Text] [Related]
19. Evolution of design considerations in complex craniofacial reconstruction using patient-specific implants.
Peel S; Bhatia S; Eggbeer D; Morris DS; Hayhurst C
Proc Inst Mech Eng H; 2017 Jun; 231(6):509-524. PubMed ID: 28019190
[TBL] [Abstract][Full Text] [Related]
20. CAD / CAM dental systems in implant dentistry: update.
Fuster-Torres MA; Albalat-Estela S; AlcaƱiz-Raya M; PeƱarrocha-Diago M
Med Oral Patol Oral Cir Bucal; 2009 Mar; 14(3):E141-5. PubMed ID: 19242395
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]