These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 36802238)

  • 21. Pseudotumors in association with well-functioning metal-on-metal hip prostheses: a case-control study using three-dimensional computed tomography and magnetic resonance imaging.
    Hart AJ; Satchithananda K; Liddle AD; Sabah SA; McRobbie D; Henckel J; Cobb JP; Skinner JA; Mitchell AW
    J Bone Joint Surg Am; 2012 Feb; 94(4):317-25. PubMed ID: 22336970
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Factors associated with symptomatic pseudotumors following metal-on-metal total hip arthroplasty.
    Hasegawa M; Naito Y; Yamaguchi T; Miyazaki S; Wakabayashi H; Sudo A
    BMC Musculoskelet Disord; 2016 Nov; 17(1):456. PubMed ID: 27821101
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Correlation between serum metal ion levels and adverse local tissue reactions after Conserve® Plus hip resurfacing arthroplasty.
    Amstutz HC; Le Duff MJ
    Hip Int; 2017 Jul; 27(4):336-342. PubMed ID: 28165598
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparative Mid-term Follow-up Study of Primary Total Hip Arthroplasty with Metal-on-metal and Metal-on-polyethylene Bearings.
    Li Z; Chen ZF; Liu JX; Liu F
    Orthop Surg; 2018 Nov; 10(4):312-320. PubMed ID: 30485684
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Metal ion levels and functional results following resurfacing hip arthroplasty versus conventional small-diameter metal-on-metal total hip arthroplasty; a 3 to 5year follow-up of a randomized controlled trial.
    Bisseling P; Smolders JM; Hol A; van Susante JL
    J Arthroplasty; 2015 Jan; 30(1):61-7. PubMed ID: 25172584
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Pseudotumor in metal-on-metal hip arthroplasty: a comparison study of three grading systems with MRI.
    Smeekes C; Schouten BJM; Nix M; Ongkiehong BF; Wolterbeek R; van der Wal BCH; Nelissen RGHH
    Skeletal Radiol; 2018 Aug; 47(8):1099-1109. PubMed ID: 29388037
    [TBL] [Abstract][Full Text] [Related]  

  • 27. No association between pseudotumors, high serum metal-ion levels and metal hypersensitivity in large-head metal-on-metal total hip arthroplasty at 5-7-year follow-up.
    Hjorth MH; Stilling M; Soballe K; Bolvig LH; Thyssen JP; Mechlenburg I; Jakobsen SS
    Skeletal Radiol; 2016 Jan; 45(1):115-25. PubMed ID: 26454451
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Are Females at Greater Risk for Revision Surgery After Hip Resurfacing Arthroplasty With the Articular Surface Replacement Prosthesis?
    Donahue GS; Lindgren V; Galea VP; Madanat R; Muratoglu O; Malchau H
    Clin Orthop Relat Res; 2016 Oct; 474(10):2257-65. PubMed ID: 27121872
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Sensitivity and Specificity of Metal Ion Levels in Predicting "Pseudotumors" due to Taper Corrosion in Patients With Dual Taper Modular Total Hip Arthroplasty.
    Kwon YM; Tsai TY; Leone WA; Liow MHL
    J Arthroplasty; 2017 Mar; 32(3):996-1000. PubMed ID: 27776907
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Asymptomatic pseudotumours after metal-on-metal hip resurfacing show little change within one year.
    van der Weegen W; Brakel K; Horn RJ; Hoekstra HJ; Sijbesma T; Pilot P; Nelissen RG
    Bone Joint J; 2013 Dec; 95-B(12):1626-31. PubMed ID: 24293591
    [TBL] [Abstract][Full Text] [Related]  

  • 31. High frequency of adverse local tissue reactions in asymptomatic patients with metal-on-metal THA.
    Fehring TK; Odum S; Sproul R; Weathersbee J
    Clin Orthop Relat Res; 2014 Feb; 472(2):517-22. PubMed ID: 23963703
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Indications for MARS-MRI in Patients Treated With Metal-on-Metal Hip Resurfacing Arthroplasty.
    Connelly JW; Galea VP; Matuszak SJ; Madanat R; Muratoglu O; Malchau H
    J Arthroplasty; 2018 Jun; 33(6):1919-1925. PubMed ID: 29606289
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Two-year serum metal ion levels in minimally invasive total conservative hip resurfacing: preliminary results of a prospective study.
    Tai SM; Millard N; Munir S; Jenabzadeh AR; Walter LR; Walter WL
    ANZ J Surg; 2015 Mar; 85(3):164-8. PubMed ID: 25288230
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Adverse Local Tissue Reactions are Common in Asymptomatic Individuals After Hip Resurfacing Arthroplasty: Interim Report from a Prospective Longitudinal Study.
    Koff MF; Gao MA; Neri JP; Chiu YF; Lin BQ; Burge AJ; Su E; Padgett DE; Potter HG
    Clin Orthop Relat Res; 2021 Dec; 479(12):2633-2650. PubMed ID: 34232144
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Prevalence of Pseudotumor in Patients After Metal-On-Metal Hip Arthroplasty Evaluated with Metal Ion Analysis and MARS-MRI.
    Sutphen SA; MacLaughlin LH; Madsen AA; Russell JH; McShane MA
    J Arthroplasty; 2016 Jan; 31(1):260-3. PubMed ID: 26253484
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A Randomized Seven-Year Study on Performance of the Stemmed Metal M2a-Magnum and Ceramic C2a-Taper, and the Resurfacing ReCap Hip Implants.
    Borgwardt A; Borgwardt L; Zerahn B; Daugaard H; Borgwardt L; Ribel-Madsen S
    J Arthroplasty; 2018 May; 33(5):1412-1420. PubMed ID: 29276121
    [TBL] [Abstract][Full Text] [Related]  

  • 37. High prevalence of pseudotumors in patients with a Birmingham Hip Resurfacing prosthesis: a prospective cohort study of one hundred and twenty-nine patients.
    Bisschop R; Boomsma MF; Van Raay JJ; Tiebosch AT; Maas M; Gerritsma CL
    J Bone Joint Surg Am; 2013 Sep; 95(17):1554-60. PubMed ID: 24005195
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The correlation between activity level, serum-ion concentrations and pseudotumours in patients with metal-on-metal hip articulations and metal-on-polyethylene total hip articulations.
    Hjorth MH; Mechlenburg I; Soballe K; Roemer L; Stilling M
    J Orthop Translat; 2019 Jul; 18():74-83. PubMed ID: 31508310
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Understanding outcomes and toxicological aspects of second generation metal-on-metal hip implants: a state-of-the-art review.
    Kovochich M; Finley BL; Novick R; Monnot AD; Donovan E; Unice KM; Fung ES; Fung D; Paustenbach DJ
    Crit Rev Toxicol; 2018 Nov; 48(10):853-901. PubMed ID: 30912993
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of extracapsular pseudotumors seen in magnetic resonance imaging and in revision surgery of 167 failed metal-on-metal hip replacements.
    Lainiala O; Elo P; Reito A; Pajamäki J; Puolakka T; Eskelinen A
    Acta Orthop; 2014 Sep; 85(5):474-9. PubMed ID: 24954485
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.