These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 36813217)

  • 1. A Review of Early In Vivo Performance of Antioxidant Stabilized Polyethylene for Total Knee Arthroplasty.
    Spece H; Yarbrough RV; Kurtz SM
    J Arthroplasty; 2023 Sep; 38(9):1885-1891. PubMed ID: 36813217
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In Vivo Performance of Vitamin E Stabilized Polyethylene Implants for Total Hip Arthroplasty: A Review.
    Spece H; Yarbrough RV; Kurtz SM
    J Arthroplasty; 2023 May; 38(5):970-979. PubMed ID: 36481286
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparable results between crosslinked polyethylene and conventional ultra-high molecular weight polyethylene implanted in total knee arthroplasty: systematic review and meta-analysis of randomised clinical trials.
    Bistolfi A; Giustra F; Bosco F; Faccenda C; Viotto M; Sabatini L; Berchialla P; Sciannameo V; Graziano E; Massè A
    Knee Surg Sports Traumatol Arthrosc; 2022 Sep; 30(9):3120-3130. PubMed ID: 35182171
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Highly cross-linked polyethylene (HXLPE) is equivalent to conventional polyethylene (CPE) in total knee arthroplasty: A systematic review and meta-analysis.
    Sheridan GA; Clesham K; Garbuz DS; Masri BA
    Knee; 2021 Dec; 33():318-326. PubMed ID: 34741831
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Is there a difference in total knee arthroplasty risk of revision in highly crosslinked versus conventional polyethylene?
    Paxton EW; Inacio MC; Kurtz S; Love R; Cafri G; Namba RS
    Clin Orthop Relat Res; 2015 Mar; 473(3):999-1008. PubMed ID: 25567357
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Highly cross-linked polyethylene decreases the rate of revision of total hip arthroplasty compared with conventional polyethylene at 13 years' follow-up.
    Hanna SA; Somerville L; McCalden RW; Naudie DD; MacDonald SJ
    Bone Joint J; 2016 Jan; 98-B(1):28-32. PubMed ID: 26733512
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Highly cross-linked polyethylene in primary total knee arthroplasty is associated with a lower rate of revision for aseptic loosening: a meta-analysis of 962,467 cases.
    Gkiatas I; Karasavvidis T; Sharma AK; Xiang W; Malahias MA; Chalmers BP; Sculco PK
    Arch Orthop Trauma Surg; 2022 Jun; 142(6):1177-1184. PubMed ID: 33847797
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Highly Cross-Linked Polyethylene Reduces Wear and Revision Rates in Total Hip Arthroplasty: A 10-Year Double-Blinded Randomized Controlled Trial.
    Devane PA; Horne JG; Ashmore A; Mutimer J; Kim W; Stanley J
    J Bone Joint Surg Am; 2017 Oct; 99(20):1703-1714. PubMed ID: 29040124
    [TBL] [Abstract][Full Text] [Related]  

  • 9. No Reduction in Revision Risk Associated With Highly Cross-linked Polyethylene With or Without Antioxidants Over Conventional Polyetheylene in TKA: An Analysis From the American Joint Replacement Registry.
    Kendall J; Pelt CE; Imlay B; Yep P; Mullen K; Kagan R
    Clin Orthop Relat Res; 2022 Oct; 480(10):1929-1936. PubMed ID: 35994277
    [TBL] [Abstract][Full Text] [Related]  

  • 10. History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene.
    Kurtz SM; Gawel HA; Patel JD
    Clin Orthop Relat Res; 2011 Aug; 469(8):2262-77. PubMed ID: 21431461
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Manufacturing, oxidation, mechanical properties and clinical performance of highly cross-linked polyethylene in total hip arthroplasty.
    Singh G; Klassen R; Howard J; Naudie D; Teeter M; Lanting B
    Hip Int; 2018 Nov; 28(6):573-583. PubMed ID: 29998768
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Otto Aufranc Award: Crosslinking Reduces THA Wear, Osteolysis, and Revision Rates at 15-year Followup Compared With Noncrosslinked Polyethylene.
    Hopper RH; Ho H; Sritulanondha S; Williams AC; Engh CA
    Clin Orthop Relat Res; 2018 Feb; 476(2):279-290. PubMed ID: 29529656
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Oxidized zirconium versus cobalt-chrome femoral heads in total hip arthroplasty: a multicentre prospective randomized controlled trial with ten years' follow-up.
    Kayani B; Baawa-Ameyaw J; Fontalis A; Tahmassebi J; Wardle N; Middleton R; Stephen A; Hutchinson J; Haddad FS
    Bone Joint J; 2022 Jul; 104-B(7):833-843. PubMed ID: 35775177
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Creep and Wear in Vitamin E-Infused Highly Cross-Linked Polyethylene Cups for Total Hip Arthroplasty: A Prospective Randomized Controlled Trial.
    Rochcongar G; Buia G; Bourroux E; Dunet J; Chapus V; Hulet C
    J Bone Joint Surg Am; 2018 Jan; 100(2):107-114. PubMed ID: 29342060
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Is Cross-Linked Polyethylene an Improvement Over Conventional Ultra-High Molecular Weight Polyethylene in Total Knee Arthroplasty?
    Boyer B; Bordini B; Caputo D; Neri T; Stea S; Toni A
    J Arthroplasty; 2018 Mar; 33(3):908-914. PubMed ID: 29089224
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ten-year follow-up study of three alternative bearing surfaces used in total hip arthroplasty in young patients: a prospective randomised controlled trial.
    Atrey A; Ward SE; Khoshbin A; Hussain N; Bogoch E; Schemitsch EH; Waddell JP
    Bone Joint J; 2017 Dec; 99-B(12):1590-1595. PubMed ID: 29212681
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reduced wear in vitamin E-infused highly cross-linked polyethylene cups: 5-year results of a randomized controlled trial.
    Rochcongar G; Remazeilles M; Bourroux E; Dunet J; Chapus V; Feron M; Praz C; Buia G; Hulet C
    Acta Orthop; 2021 Apr; 92(2):151-155. PubMed ID: 33263447
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The Relationship Between Polyethylene Wear and Periprosthetic Osteolysis in Total Hip Arthroplasty at 12 Years in a Randomized Controlled Trial Cohort.
    Broomfield JA; Malak TT; Thomas GE; Palmer AJ; Taylor A; Glyn-Jones S
    J Arthroplasty; 2017 Apr; 32(4):1186-1191. PubMed ID: 27998657
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up.
    Giustra F; Bistolfi A; Bosco F; Fresia N; Sabatini L; Berchialla P; Sciannameo V; Massè A
    Knee Surg Sports Traumatol Arthrosc; 2023 Mar; 31(3):1082-1088. PubMed ID: 36409325
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fifteen-Year Comparison of Wear and Osteolysis Analysis for Cross-Linked or Conventional Polyethylene in Cementless Total Hip Arthroplasty for Hip Dysplasia-A Retrospective Cohort Study.
    Tsukamoto M; Ohnishi H; Mori T; Kawasaki M; Uchida S; Sakai A
    J Arthroplasty; 2017 Jan; 32(1):161-165.e1. PubMed ID: 27444850
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.