These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 36813217)

  • 21. Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial.
    Scemama C; Anract P; Dumaine V; Babinet A; Courpied JP; Hamadouche M
    Int Orthop; 2017 Jun; 41(6):1113-1118. PubMed ID: 27815591
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.
    Karidakis GK; Karachalios T
    Clin Orthop Relat Res; 2015 Dec; 473(12):3836-45. PubMed ID: 26290343
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Ultra-High-Molecular-Weight Polyethylene in Hip and Knee Arthroplasties.
    Hasegawa M; Tone S; Naito Y; Sudo A
    Materials (Basel); 2023 Mar; 16(6):. PubMed ID: 36984020
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Antioxidant-stabilized highly crosslinked polyethylene in total knee arthroplasty: a retrieval analysis.
    Ponzio DY; Weitzler L; deMeireles A; Esposito CI; Wright TM; Padgett DE
    Bone Joint J; 2018 Oct; 100-B(10):1330-1335. PubMed ID: 30295528
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A vitamin E blended highly cross-linked polyethylene acetabular cup results in less wear: 6-year results of a randomized controlled trial in 199 patients.
    Massier JRA; Van Erp JHJ; Snijders TE; Gast A
    Acta Orthop; 2020 Dec; 91(6):705-710. PubMed ID: 32835560
    [TBL] [Abstract][Full Text] [Related]  

  • 26. 2-year results of an RCT of 2 uncemented isoelastic monoblock acetabular components: lower wear rate with vitamin E blended highly cross-linked polyethylene compared to ultra-high molecular weight polyethylene.
    van Erp JHJ; Massier JRA; Halma JJ; Snijders TE; de Gast A
    Acta Orthop; 2020 Jun; 91(3):254-259. PubMed ID: 32098534
    [No Abstract]   [Full Text] [Related]  

  • 27. Long-Term Wear-Related Complications of Cross-Linked Versus Conventional Polyethylene After Total Hip Arthroplasty: A Meta-Analysis.
    Yoon BH; Park JW; Lee YK; Koo KH; Chang CB
    J Arthroplasty; 2022 Nov; 37(11):2308-2315.e2. PubMed ID: 35568139
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Multicenter Study of Highly Cross-linked vs Conventional Polyethylene in Total Knee Arthroplasty.
    Meneghini RM; Ireland PH; Bhowmik-Stoker M
    J Arthroplasty; 2016 Apr; 31(4):809-14. PubMed ID: 26748405
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Durability of highly cross-linked polyethylene in total hip and total knee arthroplasty.
    Dion NT; Bragdon C; Muratoglu O; Freiberg AA
    Orthop Clin North Am; 2015 Jul; 46(3):321-7, ix. PubMed ID: 26043046
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Long-term performance of oxidized zirconium on conventional and highly cross-linked polyethylene in total hip arthroplasty.
    Carli AV; Patel AR; Cross MB; Mayman DJ; Carroll KM; Pellicci PM; Jerabek SA
    SICOT J; 2020; 6():10. PubMed ID: 32378510
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Cross-linked versus conventional polyethylene for total knee arthroplasty: a meta-analysis.
    Yu BF; Yang GJ; Wang WL; Zhang L; Lin XP
    J Orthop Surg Res; 2016 Mar; 11():39. PubMed ID: 27030048
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Clinical and Biomechanical Characteristics of Posterior-Stabilized Polyethylene Post Fractures in Total Knee Arthroplasty: A Retrieval Analysis.
    Kahlenberg CA; Baral EC; Shenoy AA; Sculco PK; Ast MP; Westrich GH; Wright TM; Carli AV
    J Arthroplasty; 2023 Jun; 38(6S):S363-S367. PubMed ID: 36813214
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Highly Cross-Linked Polyethylene Reduces Osteolysis Incidence and Wear-Related Reoperation Rate in Cementless Total Hip Arthroplasty Compared With Conventional Polyethylene at a Mean 12-Year Follow-Up.
    Tsukamoto M; Mori T; Ohnishi H; Uchida S; Sakai A
    J Arthroplasty; 2017 Dec; 32(12):3771-3776. PubMed ID: 28734615
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions.
    Affatato S; Bersaglia G; Rocchi M; Taddei P; Fagnano C; Toni A
    Biomaterials; 2005 Jun; 26(16):3259-67. PubMed ID: 15603821
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Surface Damage Is Not Reduced With Highly Crosslinked Polyethylene Tibial Inserts at Short-term.
    Liu T; Esposito C; Elpers M; Wright T
    Clin Orthop Relat Res; 2016 Jan; 474(1):107-16. PubMed ID: 26084848
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Wear and osteolysis outcomes for highly cross-linked polyethylene in primary total hip arthroplasty compared with conventional polyethylene: a 15- to 18-year single-centre follow-up study.
    Moon NH; Shin WC; Do MU; Kang SW; Lee SM; Suh KT
    Hip Int; 2021 Jul; 31(4):526-532. PubMed ID: 31912760
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Vitamin E-enriched polyethylene bearings are not inferior to Arcom bearings in primary total knee arthroplasty at medium-term follow-up.
    Ftaita S; Vanden Berghe A; Thienpont E
    Arch Orthop Trauma Surg; 2021 Jun; 141(6):1027-1033. PubMed ID: 33417026
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Incidence of Osteolysis and Aseptic Loosening Following Metal-on-Highly Cross-Linked Polyethylene Hip Arthroplasty: A Systematic Review of Studies with Up to 15-Year Follow-up.
    Prock-Gibbs H; Pumilia CA; Meckmongkol T; Lovejoy J; Mumith A; Coathup M
    J Bone Joint Surg Am; 2021 Apr; 103(8):728-740. PubMed ID: 33411465
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Reasons for Revision, Oxidation, and Damage Mechanisms of Retrieved Vitamin E-Stabilized Highly Crosslinked Polyethylene in Total Knee Arthroplasty.
    Spece H; Schachtner JT; MacDonald DW; Klein GR; Mont MA; Lee GC; Kurtz SM
    J Arthroplasty; 2019 Dec; 34(12):3088-3093. PubMed ID: 31416742
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Cross-Linked Versus Conventional Polyethylene for Long-Term Clinical Outcomes After Total Hip Arthroplasty: A Systematic Review and Meta-Analysis.
    Shi J; Zhu W; Liang S; Li H; Li S
    J Invest Surg; 2021 Mar; 34(3):307-317. PubMed ID: 31266381
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.