BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 36815435)

  • 21. Additively manufactured CAD-CAM complete dentures with intraoral scanning and cast digitization: A controlled clinical trial.
    Al-Kaff FT; Al Hamad KQ
    J Prosthodont; 2024 Jan; 33(1):27-33. PubMed ID: 37200587
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Quantitative evaluation of printing accuracy and tissue surface adaptation of mandibular complete denture polylactic acid pattern fabricated by fused deposition modeling technology].
    Deng KH; Wang Y; Chen H; Zhao YJ; Zhou YS; Sun YC
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2017 Jun; 52(6):342-345. PubMed ID: 28613054
    [No Abstract]   [Full Text] [Related]  

  • 23. Prosthesis accuracy of fit on 3D-printed casts versus stone casts: A comparative study in the anterior maxilla.
    Abdeen L; Chen YW; Kostagianni A; Finkelman M; Papathanasiou A; Chochlidakis K; Papaspyridakos P
    J Esthet Restor Dent; 2022 Dec; 34(8):1238-1246. PubMed ID: 36415927
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Digital Versus Conventional Full-Arch Implant Impressions: A Prospective Study on 16 Edentulous Maxillae.
    Chochlidakis K; Papaspyridakos P; Tsigarida A; Romeo D; Chen YW; Natto Z; Ercoli C
    J Prosthodont; 2020 Apr; 29(4):281-286. PubMed ID: 32166793
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evaluation of Denture Base Adaptation Fabricated Using Conventional, Subtractive, and Additive Technologies: A Volumetric Micro-Computed Tomography Analysis.
    Oğuz Eİ; Kılıçarslan MA; Özcan M; Ocak M; Bilecenoğlu B; Orhan K
    J Prosthodont; 2021 Mar; 30(3):257-263. PubMed ID: 33415779
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Accuracy and reproducibility of virtual edentulous casts created by laboratory impression scan protocols.
    Peng L; Chen L; Harris BT; Bhandari B; Morton D; Lin WS
    J Prosthet Dent; 2018 Sep; 120(3):389-395. PubMed ID: 29703675
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Design of Complete Dentures by Adopting CAD Developed for Fixed Prostheses.
    Li Y; Han W; Cao J; Iv Y; Zhang Y; Han Y; Shen Y; Ma Z; Liu H
    J Prosthodont; 2018 Feb; 27(2):212-219. PubMed ID: 27870167
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Fabricating complete dentures with CAD/CAM technology.
    Infante L; Yilmaz B; McGlumphy E; Finger I
    J Prosthet Dent; 2014 May; 111(5):351-5. PubMed ID: 24461946
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Design and fabrication of complete dentures using CAD/CAM technology.
    Han W; Li Y; Zhang Y; Lv Y; Zhang Y; Hu P; Liu H; Ma Z; Shen Y
    Medicine (Baltimore); 2017 Jan; 96(1):e5435. PubMed ID: 28072686
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Functional impression and jaw registration: a single session procedure for the construction of complete dentures.
    Utz KH; Müller F; Kettner N; Reppert G; Koeck B
    J Oral Rehabil; 2004 Jun; 31(6):554-61. PubMed ID: 15189312
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Accuracy evaluation of a new three-dimensional reproduction method of edentulous dental casts, and wax occlusion rims with jaw relation.
    Yuan FS; Sun YC; Wang Y; Lü PJ
    Int J Oral Sci; 2013 Sep; 5(3):155-61. PubMed ID: 23907676
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The digitally replicated denture technique: A case report.
    Clark WA; Duqum I; Kowalski BJ
    J Esthet Restor Dent; 2019 Jan; 31(1):20-25. PubMed ID: 30537418
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Final-impression techniques and materials for making complete and removable partial dentures.
    Jayaraman S; Singh BP; Ramanathan B; Pazhaniappan Pillai M; MacDonald L; Kirubakaran R
    Cochrane Database Syst Rev; 2018 Apr; 4(4):CD012256. PubMed ID: 29617037
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Accuracy of digitally fabricated trial dentures.
    Wimmer T; Eichberger M; Lümkemann N; Stawarczyk B
    J Prosthet Dent; 2018 Jun; 119(6):942-947. PubMed ID: 28969915
    [TBL] [Abstract][Full Text] [Related]  

  • 35. CAD/CAM complete dentures: a review of two commercial fabrication systems.
    Kattadiyil MT; Goodacre CJ; Baba NZ
    J Calif Dent Assoc; 2013 Jun; 41(6):407-16. PubMed ID: 23875432
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effect of Duplication Techniques on the Fitting Accuracy of CAD-CAM Milled, 3D-Printed, and Injection-Molded Mandibular Complete Denture Bases.
    Emam AM; El-Esawy AA; Alyami MH; Baraka Y; Gad MM; Helal MA
    Dent J (Basel); 2024 Feb; 12(2):. PubMed ID: 38392236
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A CAD/CAM system for removable denture. Part I: Fabrication of complete dentures.
    Maeda Y; Minoura M; Tsutsumi S; Okada M; Nokubi T
    Int J Prosthodont; 1994; 7(1):17-21. PubMed ID: 8179777
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Trial of a CAD/CAM system for fabricating complete dentures.
    Kanazawa M; Inokoshi M; Minakuchi S; Ohbayashi N
    Dent Mater J; 2011; 30(1):93-6. PubMed ID: 21282882
    [TBL] [Abstract][Full Text] [Related]  

  • 39. In vitro comparative study between complete arch conventional implant impressions and digital implant scans with scannable pick-up impression copings.
    Conejo J; Yoo TH; Atria PJ; Fraiman H; Blatz MB
    J Prosthet Dent; 2024 Mar; 131(3):475.e1-475.e7. PubMed ID: 38182453
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Evaluation of one-piece polyetheretherketone removable partial denture fabricated by computer-aided design and computer-aided manufacturing].
    Li XX; Liu YS; Sun YC; Chen H; Ye HQ; Zhou YS
    Beijing Da Xue Xue Bao Yi Xue Ban; 2019 Apr; 51(2):335-339. PubMed ID: 30996378
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.