These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

237 related articles for article (PubMed ID: 36816558)

  • 1. Noninvasive intracranial pressure assessment by optic nerve sheath diameter: Automated measurements as an alternative to clinician-performed measurements.
    Netteland DF; Aarhus M; Smistad E; Sandset EC; Padayachy L; Helseth E; Brekken R
    Front Neurol; 2023; 14():1064492. PubMed ID: 36816558
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Noninvasive Assessment of Intracranial Pressure: Deformability Index as an Adjunct to Optic Nerve Sheath Diameter to Increase Diagnostic Ability.
    Netteland DF; Aarhus M; Sandset EC; Padayachy L; Helseth E; Brekken R
    Neurocrit Care; 2024 Oct; 41(2):479-488. PubMed ID: 38448744
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Noninvasive Transorbital Assessment of the Optic Nerve Sheath in Children: Relationship Between Optic Nerve Sheath Diameter, Deformability Index, and Intracranial Pressure.
    Padayachy L; Brekken R; Fieggen G; Selbekk T
    Oper Neurosurg (Hagerstown); 2019 Jun; 16(6):726-733. PubMed ID: 30169680
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ultrasonographic Assessment of Optic Nerve Sheath Diameter as a Screening Tool for Intracranial Hypertension in Traumatic Brain Injury.
    Lioi F; Ramm-Pettersen J; Fratini A; Riva C; Colella N; Missori P
    World Neurosurg; 2024 Aug; ():. PubMed ID: 39209251
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Using Optic Nerve Sheath Diameter for Intracranial Pressure (ICP) Monitoring in Traumatic Brain Injury: A Scoping Review.
    Martínez-Palacios K; Vásquez-García S; Fariyike OA; Robba C; Rubiano AM;
    Neurocrit Care; 2024 Jun; 40(3):1193-1212. PubMed ID: 38114797
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Correlation of the transorbital ultrasonographic optic nerve sheath diameter with intracranial pressure measured intraoperatively in infants with hydrocephalus.
    Okpara SE; Uche EO; Iloanusi NI; Iloabachie IC; Mezue WC; Onyia EE; Chikani MC; Mathew M
    J Neurosurg Pediatr; 2024 Apr; 33(4):334-342. PubMed ID: 38215445
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure.
    Maissan IM; Dirven PJ; Haitsma IK; Hoeks SE; Gommers D; Stolker RJ
    J Neurosurg; 2015 Sep; 123(3):743-7. PubMed ID: 25955869
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of accuracy of optic nerve ultrasound for the detection of intracranial hypertension in the setting of acutely fluctuating vs stable intracranial pressure: post-hoc analysis of data from a prospective, blinded single center study.
    Rajajee V; Fletcher JJ; Rochlen LR; Jacobs TL
    Crit Care; 2012 May; 16(3):R79. PubMed ID: 22578001
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optic nerve sheath diameter and pulsatility index for the diagnosis and follow-up in pediatric traumatic brain injury: a prospective observational cohort study.
    Saritas Nakip O; Pektezel MY; Terzi K; Kesici S; Bayrakci B
    Childs Nerv Syst; 2023 Sep; 39(9):2467-2477. PubMed ID: 37099137
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pcv-aCO
    Jiang H; Xie Z; Yang L; Wang H
    Int J Gen Med; 2024; 17():4519-4528. PubMed ID: 39398485
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ratio of Optic Nerve Sheath Diameter to Eyeball Transverse Diameter by Ultrasound Can Predict Intracranial Hypertension in Traumatic Brain Injury Patients: A Prospective Study.
    Du J; Deng Y; Li H; Qiao S; Yu M; Xu Q; Wang C
    Neurocrit Care; 2020 Apr; 32(2):478-485. PubMed ID: 31218637
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Correlation of intracranial pressure and diameter of the sheath of the optic nerve by computed tomography in severe traumatic brain injury].
    Turkin AM; Oshorov AV; Pogosbekyan EL; Smirnov AS; Dmitrieva AS
    Zh Vopr Neirokhir Im N N Burdenko; 2017; 81(6):81-88. PubMed ID: 29393290
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Correlation of Optic Nerve Sheath Diameter with Direct Measurement of Intracranial Pressure through an External Ventricular Drain.
    Ali MA; Hashmi M; Shamim S; Salam B; Siraj S; Salim B
    Cureus; 2019 Sep; 11(9):e5777. PubMed ID: 31723536
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Novel Algorithm for Automated Optic Nerve Sheath Diameter Measurement Using a Clustering Approach.
    Rajajee V; Soroushmehr R; Williamson CA; Najarian K; Gryak J; Awad A; Ward KR; Tiba MH
    Mil Med; 2021 Jan; 186(Suppl 1):496-501. PubMed ID: 32830251
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optic nerve ultrasound for the detection of raised intracranial pressure.
    Rajajee V; Vanaman M; Fletcher JJ; Jacobs TL
    Neurocrit Care; 2011 Dec; 15(3):506-15. PubMed ID: 21769456
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Correlation between ultrasonographic optic nerve sheath diameter and intracranial pressure].
    Li Z; Zhang XX; Yang HQ; Zhao LP; Jia JP; Sun F; Liu DC
    Zhonghua Yan Ke Za Zhi; 2018 Sep; 54(9):683-687. PubMed ID: 30220184
    [No Abstract]   [Full Text] [Related]  

  • 17. Sonographic optic nerve sheath diameter as an estimate of intracranial pressure in adult trauma.
    Strumwasser A; Kwan RO; Yeung L; Miraflor E; Ereso A; Castro-Moure F; Patel A; Sadjadi J; Victorino GP
    J Surg Res; 2011 Oct; 170(2):265-71. PubMed ID: 21550065
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optic nerve sheath diameter on computed tomography is correlated with simultaneously measured intracranial pressure in patients with severe traumatic brain injury.
    Sekhon MS; Griesdale DE; Robba C; McGlashan N; Needham E; Walland K; Shook AC; Smielewski P; Czosnyka M; Gupta AK; Menon DK
    Intensive Care Med; 2014 Sep; 40(9):1267-74. PubMed ID: 25034476
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure.
    Kimberly HH; Shah S; Marill K; Noble V
    Acad Emerg Med; 2008 Feb; 15(2):201-4. PubMed ID: 18275454
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children. : Part II: age-related ONSD cut-off values and patency of the anterior fontanelle.
    Padayachy LC; Padayachy V; Galal U; Pollock T; Fieggen AG
    Childs Nerv Syst; 2016 Oct; 32(10):1779-85. PubMed ID: 27659820
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.