These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
186 related articles for article (PubMed ID: 36822876)
1. An adaptive fuzzy logic control technique for LVRT enhancement of a grid-integrated DFIG-based wind energy conversion system. Chakraborty A; Maity T ISA Trans; 2023 Jul; 138():720-734. PubMed ID: 36822876 [TBL] [Abstract][Full Text] [Related]
2. Optimal low voltage ride through of wind turbine doubly fed induction generator based on bonobo optimization algorithm. Mostafa MA; El-Hay EA; Elkholy MM Sci Rep; 2023 May; 13(1):7778. PubMed ID: 37179378 [TBL] [Abstract][Full Text] [Related]
3. Fault ride-through enhancement using an enhanced field oriented control technique for converters of grid connected DFIG and STATCOM for different types of faults. Ananth DV; Nagesh Kumar GV ISA Trans; 2016 May; 62():2-18. PubMed ID: 25840675 [TBL] [Abstract][Full Text] [Related]
4. Power regulation of variable speed multi rotor wind systems using fuzzy cascaded control. Benbouhenni H; Colak I; Bizon N; Mosaad MI; Tella TG Sci Rep; 2024 Jul; 14(1):16415. PubMed ID: 39014030 [TBL] [Abstract][Full Text] [Related]
5. Doubly fed induction generator wind turbines with fuzzy controller: a survey. Sathiyanarayanan JS; Kumar AS ScientificWorldJournal; 2014; 2014():252645. PubMed ID: 25028677 [TBL] [Abstract][Full Text] [Related]
6. Dynamic response and low voltage ride-through enhancement of brushless double-fed induction generator using Salp swarm optimization algorithm. Memon A; Wazir Bin Mustafa M; Anjum W; Ahmed A; Ullah S; Altbawi SMA; Jumani TA; Khan I; Hamadneh NN PLoS One; 2022; 17(5):e0265611. PubMed ID: 35551274 [TBL] [Abstract][Full Text] [Related]
7. Enhancing low voltage ride through capability of grid connected DFIG based WECS using WCA-PSO tuned STATCOM controller. Muisyo IN; Muriithi CM; Kamau SI Heliyon; 2022 Aug; 8(8):e09999. PubMed ID: 36016517 [TBL] [Abstract][Full Text] [Related]
8. Differential Evolution Based IDWNN Controller for Fault Ride-Through of Grid-Connected Doubly Fed Induction Wind Generators. Manonmani N; Subbiah V; Sivakumar L ScientificWorldJournal; 2015; 2015():746017. PubMed ID: 26516636 [TBL] [Abstract][Full Text] [Related]
9. Improved fault ride through capability of DFIG based wind turbines using synchronous reference frame control based dynamic voltage restorer. Rini Ann Jerin A; Kaliannan P; Subramaniam U ISA Trans; 2017 Sep; 70():465-474. PubMed ID: 28689698 [TBL] [Abstract][Full Text] [Related]
10. Real-time Neural Inverse Optimal Control for Low-Voltage Rid-Through enhancement of Double Fed Induction Generator based Wind Turbines. Djilali L; Sanchez EN; Ornelas-Tellez F; Ruz-Hernandez JA; Ricalde LJ ISA Trans; 2021 Jul; 113():111-126. PubMed ID: 32434665 [TBL] [Abstract][Full Text] [Related]
11. Adaptive hybrid intelligent MPPT controller to approximate effectual wind speed and optimal rotor speed of variable speed wind turbine. Sitharthan R; Karthikeyan M; Sundar DS; Rajasekaran S ISA Trans; 2020 Jan; 96():479-489. PubMed ID: 31202532 [TBL] [Abstract][Full Text] [Related]
12. Evaluating a Hybrid Circuit Topology for Fault-Ride through in DFIG-Based Wind Turbines. Saeed S; Asghar R; Mehmood F; Saleem H; Azeem B; Ullah Z Sensors (Basel); 2022 Nov; 22(23):. PubMed ID: 36502016 [TBL] [Abstract][Full Text] [Related]
13. An improved low-voltage ride-through performance of DFIG based wind plant using stator dynamic composite fault current limiter. Gayen PK; Chatterjee D; Goswami SK ISA Trans; 2016 May; 62():333-48. PubMed ID: 26876377 [TBL] [Abstract][Full Text] [Related]
14. Low-voltage ride-through capability in a DFIG using FO-PID and RCO techniques under symmetrical and asymmetrical faults. Sabzevari K; Khosravi N; Abdelghany MB; Belkhier Y; Tostado-Véliz M; Kotb H; Govender S Sci Rep; 2023 Oct; 13(1):17534. PubMed ID: 37845297 [TBL] [Abstract][Full Text] [Related]
15. Performance comparison between PID and Fuzzy logic controllers for the hardware implementation of traditional high voltage DC-DC boost converter. G N; J K Heliyon; 2024 Sep; 10(17):e36750. PubMed ID: 39263068 [TBL] [Abstract][Full Text] [Related]
16. Marine Predator Algorithm-Based Optimal PI Controllers for LVRT Capability Enhancement of Grid-Connected PV Systems. Ellithy HH; Hasanien HM; Alharbi M; Sobhy MA; Taha AM; Attia MA Biomimetics (Basel); 2024 Jan; 9(2):. PubMed ID: 38392112 [TBL] [Abstract][Full Text] [Related]
17. Optimization of Fuzzy Control Parameters for Wind Farms and Battery Energy Storage Systems Based on an Enhanced Artificial Bee Colony Algorithm under Multi-Source Sensor Data. Liu Z; Yang P; Zhang P; Lin X; Wei J; Li N Sensors (Basel); 2024 Aug; 24(16):. PubMed ID: 39204814 [TBL] [Abstract][Full Text] [Related]
18. A Distributed Control Scheme Using SiC-Based Low Voltage Ride-Through Compensator for Wind Turbine Generators. Ma CT; Shi ZH Micromachines (Basel); 2021 Dec; 13(1):. PubMed ID: 35056204 [TBL] [Abstract][Full Text] [Related]
19. Enhancing grid-connected photovoltaic system performance with novel hybrid MPPT technique in variable atmospheric conditions. Zaghba L; Borni A; Benbitour MK; Fezzani A; Alwabli A; Bajaj M; Dost Mohammadi SA; Ghoneim SSM Sci Rep; 2024 Apr; 14(1):8205. PubMed ID: 38589473 [TBL] [Abstract][Full Text] [Related]
20. Deadbeat-fuzzy controller for the power control of a Doubly Fed Induction Generator based wind power system. Rocha-Osorio CM; Solís-Chaves JS; Rodrigues LL; Puma JLA; Sguarezi Filho AJ ISA Trans; 2019 May; 88():258-267. PubMed ID: 30545774 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]