BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 36827954)

  • 1. Lupus anticoagulant laboratory diagnosis by applying the 2020 ISTH-SSC guidelines.
    Talon L; Fourneyron V; Senectaire S; Tardieu M; Tillier M; Trapani A; Trayaud A; Vaissade A; Sapin AF; Lebreton A; Sinegre T
    Thromb Res; 2023 Apr; 224():38-45. PubMed ID: 36827954
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Variability of cut-off values for the detection of lupus anticoagulants: results of an international multicenter multiplatform study.
    Tripodi A; Chantarangkul V; Cini M; Devreese K; Dlott JS; Giacomello R; Gray E; Legnani C; Martinuzzo ME; Pradella P; Siegemund A; Subramanian S; Suchon P; Testa S
    J Thromb Haemost; 2017 Jun; 15(6):1180-1190. PubMed ID: 28316135
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Variability among commercial batches of normal pooled plasma in lupus anticoagulant testing.
    Cabo J; Morimont L; Baudar J; Guldenpfennig M; Jacqmin H; Soleimani R; Lecompte T; Douxfils J; Mullier F
    Int J Lab Hematol; 2023 Feb; 45(1):126-136. PubMed ID: 36222181
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Guidance from the Scientific and Standardization Committee for lupus anticoagulant/antiphospholipid antibodies of the International Society on Thrombosis and Haemostasis: Update of the guidelines for lupus anticoagulant detection and interpretation.
    Devreese KMJ; de Groot PG; de Laat B; Erkan D; Favaloro EJ; Mackie I; Martinuzzo M; Ortel TL; Pengo V; Rand JH; Tripodi A; Wahl D; Cohen H
    J Thromb Haemost; 2020 Nov; 18(11):2828-2839. PubMed ID: 33462974
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Applying index of circulating anticoagulant to mixing tests with lupus anticoagulant screen and confirm reagents can distinguish with high specificity between lupus anticoagulants and direct factor Xa inhibitors.
    Kumano O; Amiral J; Dunois C; Peyrafitte M; Moore GW
    Int J Lab Hematol; 2021 Aug; 43(4):771-778. PubMed ID: 33974363
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mixing test specific cut-off is more sensitive at detecting lupus anticoagulants than index of circulating anticoagulant.
    Moore GW; Culhane AP; Daw CR; Noronha CP; Kumano O
    Thromb Res; 2016 Mar; 139():98-101. PubMed ID: 26916303
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dilute Russell's viper venom and activated partial thromboplastin time in lupus anticoagulant diagnosis: is mixing essential?
    Chandrashekar V
    Blood Coagul Fibrinolysis; 2016 Jun; 27(4):408-11. PubMed ID: 26626041
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Validation of mixing test-specific cut-off in lupus anticoagulant mixing test interpretation for multiple reagents.
    Kumano O; Moore GW
    Thromb Res; 2023 Nov; 231():39-43. PubMed ID: 37801773
    [No Abstract]   [Full Text] [Related]  

  • 9. Coagulation tests and anti-phospholipid antibodies in patients positive for lupus anticoagulant.
    Sakakura M; Wada H; Watanabe R; Mamamuro M; Okugawa Y; Nakasaki T; Nakase T; Wakita Y; Minamikawa K; Mori Y; Nshikawa M; Shiku H
    Clin Appl Thromb Hemost; 2000 Jul; 6(3):144-50. PubMed ID: 10898274
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mixing studies in lupus anticoagulant testing are required at least in some type of samples.
    Devreese KM; de Laat B
    J Thromb Haemost; 2015 Aug; 13(8):1475-8. PubMed ID: 26017873
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Differences in lupus anticoagulant final conclusion through clotting time or Rosner index for mixing test interpretation.
    Depreter B; Devreese KM
    Clin Chem Lab Med; 2016 Sep; 54(9):1511-6. PubMed ID: 26894579
    [TBL] [Abstract][Full Text] [Related]  

  • 12. New guidelines for lupus anticoagulant: sensitivity and specificity of cut-off values calculated with plasmas from healthy controls in mixing and confirmatory tests.
    Martinuzzo ME; Cerrato GS; Varela ML; Adamczuk YP; Forastiero RR
    Int J Lab Hematol; 2012 Apr; 34(2):208-13. PubMed ID: 22032515
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Lupus Anticoagulant Testing: Dilute Prothrombin Time (dPT).
    Moore GW
    Methods Mol Biol; 2023; 2663():275-288. PubMed ID: 37204717
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The dilution effect of equal volume mixing studies compromises confirmation of inhibition by lupus anticoagulants even when mixture specific reference ranges are applied.
    Moore GW; Savidge GF
    Thromb Res; 2006; 118(4):523-8. PubMed ID: 16263154
    [TBL] [Abstract][Full Text] [Related]  

  • 15. International multicenter, multiplatform study to validate Taipan snake venom time as a lupus anticoagulant screening test with ecarin time as the confirmatory test: Communication from the ISTH SSC Subcommittee on Lupus Anticoagulant/Antiphospholipid Antibodies.
    Moore GW; Jones PO; Platton S; Hussain N; White D; Thomas W; Rigano J; Pouplard C; Gray E; Devreese KMJ
    J Thromb Haemost; 2021 Dec; 19(12):3177-3192. PubMed ID: 34192404
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical usefulness of the dilute Russell viper venom time test for patients taking warfarin.
    Kanouchi K; Narimatsu H; Ohnuma O; Morikane K; Fukao A
    Int J Hematol; 2017 Aug; 106(2):206-211. PubMed ID: 28390037
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical significance of the mixing test in laboratory diagnoses of lupus anticoagulant: the fate of the mixing test in integrated lupus anticoagulant test systems.
    Hong SK; Hwang SM; Kim JE; Kim HK
    Blood Coagul Fibrinolysis; 2012 Dec; 23(8):739-44. PubMed ID: 22964767
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The activated seven lupus anticoagulant assay detects clinically significant antibodies.
    Moore GW; Rangarajan S; Savidge GF
    Clin Appl Thromb Hemost; 2008 Jul; 14(3):332-7. PubMed ID: 17895508
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Testing for Lupus Anticoagulants.
    Moore GW
    Semin Thromb Hemost; 2022 Sep; 48(6):643-660. PubMed ID: 35649428
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Commonalities and contrasts in recent guidelines for lupus anticoagulant detection.
    Moore GW
    Int J Lab Hematol; 2014 Jun; 36(3):364-73. PubMed ID: 24750683
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.