These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 36835015)

  • 1. An Experimental Anodized and Low-Pressure Oxygen Plasma-Treated Titanium Dental Implant Surface-Preliminary Report.
    Hadzik J; Jurczyszyn K; Gębarowski T; Trytek A; Gedrange T; Kozakiewicz M; Dominiak M; Kubasiewicz-Ross P; Trzcionka-Szajna A; Szajna E; Simka W
    Int J Mol Sci; 2023 Feb; 24(4):. PubMed ID: 36835015
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Plasma Electrolytic Oxidation of Titanium Implant Surfaces: Microgroove-Structures Improve Cellular Adhesion and Viability.
    Hartjen P; Hoffmann A; Henningsen A; Barbeck M; Kopp A; Kluwe L; Precht C; Quatela O; Gaudin R; Heiland M; Friedrich RE; Knipfer C; Grubeanu D; Smeets R; Jung O
    In Vivo; 2018; 32(2):241-247. PubMed ID: 29475905
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Osseointegration of Titanium Implants With Different Rough Surfaces: A Histologic and Histomorphometric Study in an Adult Minipig Model.
    Fabbro MD; Taschieri S; Canciani E; Addis A; Musto F; Weinstein R; Dellavia C
    Implant Dent; 2017 Jun; 26(3):357-366. PubMed ID: 28234707
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In Vivo Effect of Titanium Implants with Porous Zinc-Containing Coatings Prepared by Plasma Electrolytic Oxidation Method on Osseointegration in Rabbits.
    He J; Feng W; Zhao BH; Zhang W; Lin Z
    Int J Oral Maxillofac Implants; 2018; 33(2):298–310. PubMed ID: 29420672
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Osseointegration improvement by plasma electrolytic oxidation of modified titanium alloys surfaces.
    Echeverry-Rendón M; Galvis O; Quintero Giraldo D; Pavón J; López-Lacomba JL; Jiménez-Piqué E; Anglada M; Robledo SM; Castaño JG; Echeverría F
    J Mater Sci Mater Med; 2015 Feb; 26(2):72. PubMed ID: 25631270
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of early osseointegration between laser-treated/acid-etched and sandblasted/acid-etched titanium implant surfaces.
    Rong M; Lu H; Wan L; Zhang X; Lin X; Li S; Zhou L; Lv Y; Su Y
    J Mater Sci Mater Med; 2018 Mar; 29(4):43. PubMed ID: 29603028
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Changes in the esthetic, physical, and biological properties of a titanium alloy abutment treated by anodic oxidation.
    Wang T; Wang L; Lu Q; Fan Z
    J Prosthet Dent; 2019 Jan; 121(1):156-165. PubMed ID: 30093130
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modification of titanium alloys surface properties by plasma electrolytic oxidation (PEO) and influence on biological response.
    Echeverry-Rendón M; Galvis O; Aguirre R; Robledo S; Castaño JG; Echeverría F
    J Mater Sci Mater Med; 2017 Sep; 28(11):169. PubMed ID: 28956201
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of Plasma Oxidation-Treated TiOx Film on Early Osseointegration.
    Jiang H; Zhang T; Zhou W; Lin Z; Liu Z
    Int J Oral Maxillofac Implants; 2018; 33(5):1011-1018. PubMed ID: 30231086
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Surface analysis of machined versus sandblasted and acid-etched titanium implants.
    Orsini G; Assenza B; Scarano A; Piattelli M; Piattelli A
    Int J Oral Maxillofac Implants; 2000; 15(6):779-84. PubMed ID: 11151575
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Synthesis of bioactive glass-based coating by plasma electrolytic oxidation: Untangling a new deposition pathway toward titanium implant surfaces.
    Costa RC; Souza JGS; Cordeiro JM; Bertolini M; de Avila ED; Landers R; Rangel EC; Fortulan CA; Retamal-Valdes B; da Cruz NC; Feres M; Barão VAR
    J Colloid Interface Sci; 2020 Nov; 579():680-698. PubMed ID: 32652323
    [TBL] [Abstract][Full Text] [Related]  

  • 12. PEO-generated Surfaces Support Attachment and Growth of Cells In Vitro with No Additional Benefit for Micro-roughness in Sa (0.2-4 μm).
    Jung O; Smeets R; Kopp A; Porchetta D; Hiester P; Heiland M; Friedrich RE; Precht C; Hanken H; Gröbe A; Hartjen P
    In Vivo; 2016; 30(1):27-33. PubMed ID: 26709125
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An Experimental Anodized Titanium Surface for Transgingival Dental Implant Elements-Preliminary Report.
    Hadzik J; Kubasiewicz-Ross P; Gębarowski T; Waloszczyk N; Maciej A; Stolarczyk A; Gedrange T; Dominiak M; Szajna E; Simka W
    J Funct Biomater; 2023 Jan; 14(1):. PubMed ID: 36662081
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical and histomorphometric comparison between zirconia implants with varying surface textures and a titanium implant in the maxilla of miniature pigs.
    Gahlert M; Gudehus T; Eichhorn S; Steinhauser E; Kniha H; Erhardt W
    Clin Oral Implants Res; 2007 Oct; 18(5):662-8. PubMed ID: 17608736
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of the sources of calcium and phosphorus on the structural and functional properties of ceramic coatings on titanium dental implants produced by plasma electrolytic oxidation.
    Kyrylenko S; Warchoł F; Oleshko O; Husak Y; Kazek-Kęsik A; Korniienko V; Deineka V; Sowa M; Maciej A; Michalska J; Jakóbik-Kolon A; Matuła I; Basiaga M; Hulubnycha V; Stolarczyk A; Pisarek M; Mishchenko O; Pogorielov M; Simka W
    Mater Sci Eng C Mater Biol Appl; 2021 Feb; 119():111607. PubMed ID: 33321651
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [An experimental study of Zn/Ca/P-containing coatings on titanium implant surface modified by plasma electrolytic oxidation].
    Feng W; Zhao BH; Zhang W; Lin Z
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2019 Jan; 54(1):46-51. PubMed ID: 30630259
    [No Abstract]   [Full Text] [Related]  

  • 17. Improved in vitro angiogenic behavior on anodized titanium dioxide nanotubes.
    Beltrán-Partida E; Valdéz-Salas B; Moreno-Ulloa A; Escamilla A; Curiel MA; Rosales-Ibáñez R; Villarreal F; Bastidas DM; Bastidas JM
    J Nanobiotechnology; 2017 Jan; 15(1):10. PubMed ID: 28143540
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison between Sandblasted Acid-Etched and Oxidized Titanium Dental Implants: In Vivo Study.
    Velasco-Ortega E; Ortiz-García I; Jiménez-Guerra A; Monsalve-Guil L; Muñoz-Guzón F; Perez RA; Gil FJ
    Int J Mol Sci; 2019 Jul; 20(13):. PubMed ID: 31277204
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In vivo monitoring of the bone healing process around different titanium alloy implant surfaces placed into fresh extraction sockets.
    Colombo JS; Satoshi S; Okazaki J; Crean SJ; Sloan AJ; Waddington RJ
    J Dent; 2012 Apr; 40(4):338-46. PubMed ID: 22307025
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Nitrilotriacetic Acid Improves Plasma Electrolytic Oxidation of Titanium for Biomedical Applications.
    Kyrylenko S; Sowa M; Kazek-Kęsik A; Stolarczyk A; Pisarek M; Husak Y; Korniienko V; Deineka V; Moskalenko R; Matuła I; Michalska J; Jakóbik-Kolon A; Mishchenko O; Pogorielov M; Simka W
    ACS Appl Mater Interfaces; 2023 Apr; 15(16):19863-19876. PubMed ID: 37041124
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.