These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 36844249)

  • 1. PulseDB: A large, cleaned dataset based on MIMIC-III and VitalDB for benchmarking cuff-less blood pressure estimation methods.
    Wang W; Mohseni P; Kilgore KL; Najafizadeh L
    Front Digit Health; 2022; 4():1090854. PubMed ID: 36844249
    [TBL] [Abstract][Full Text] [Related]  

  • 2. KD-Informer: A Cuff-Less Continuous Blood Pressure Waveform Estimation Approach Based on Single Photoplethysmography.
    Ma C; Zhang P; Song F; Sun Y; Fan G; Zhang T; Feng Y; Zhang G
    IEEE J Biomed Health Inform; 2023 May; 27(5):2219-2230. PubMed ID: 35700247
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An Estimation Method of Continuous Non-Invasive Arterial Blood Pressure Waveform Using Photoplethysmography: A U-Net Architecture-Based Approach.
    Athaya T; Choi S
    Sensors (Basel); 2021 Mar; 21(5):. PubMed ID: 33800106
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Continuous blood pressure measurement from one-channel electrocardiogram signal using deep-learning techniques.
    Miao F; Wen B; Hu Z; Fortino G; Wang XP; Liu ZD; Tang M; Li Y
    Artif Intell Med; 2020 Aug; 108():101919. PubMed ID: 32972654
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intensive care photoplethysmogram datasets and machine-learning for blood pressure estimation: Generalization not guarantied.
    Weber-Boisvert G; Gosselin B; Sandberg F
    Front Physiol; 2023; 14():1126957. PubMed ID: 36935753
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Δ BP-Net: Monitoring "Changes" in Blood Pressure Using PPG with Self-contrastive Masking.
    Wang W; Mohseni P; Kilgore KL; Najafizadeh L
    IEEE J Biomed Health Inform; 2024 Jul; PP():. PubMed ID: 38954566
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A hybrid neural network for continuous and non-invasive estimation of blood pressure from raw electrocardiogram and photoplethysmogram waveforms.
    Baker S; Xiang W; Atkinson I
    Comput Methods Programs Biomed; 2021 Aug; 207():106191. PubMed ID: 34077866
    [TBL] [Abstract][Full Text] [Related]  

  • 8. DeepCNAP: A Deep Learning Approach for Continuous Noninvasive Arterial Blood Pressure Monitoring Using Photoplethysmography.
    Kim DK; Kim YT; Kim H; Kim DJ
    IEEE J Biomed Health Inform; 2022 Aug; 26(8):3697-3707. PubMed ID: 35511844
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Continuous Blood Pressure Estimation From Electrocardiogram and Photoplethysmogram During Arrhythmias.
    Liu Z; Zhou B; Li Y; Tang M; Miao F
    Front Physiol; 2020; 11():575407. PubMed ID: 33013491
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Highly wearable cuff-less blood pressure and heart rate monitoring with single-arm electrocardiogram and photoplethysmogram signals.
    Zhang Q; Zhou D; Zeng X
    Biomed Eng Online; 2017 Feb; 16(1):23. PubMed ID: 28166774
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Blood Pressure Estimation from Photoplethysmogram Using a Spectro-Temporal Deep Neural Network.
    Slapničar G; Mlakar N; Luštrek M
    Sensors (Basel); 2019 Aug; 19(15):. PubMed ID: 31382703
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characters available in photoplethysmogram for blood pressure estimation: beyond the pulse transit time.
    Li Y; Wang Z; Zhang L; Yang X; Song J
    Australas Phys Eng Sci Med; 2014 Jun; 37(2):367-76. PubMed ID: 24722801
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A Shallow U-Net Architecture for Reliably Predicting Blood Pressure (BP) from Photoplethysmogram (PPG) and Electrocardiogram (ECG) Signals.
    Mahmud S; Ibtehaz N; Khandakar A; Tahir AM; Rahman T; Islam KR; Hossain MS; Rahman MS; Musharavati F; Ayari MA; Islam MT; Chowdhury MEH
    Sensors (Basel); 2022 Jan; 22(3):. PubMed ID: 35161664
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Photoplethysmography Fast Upstroke Time Intervals Can Be Useful Features for Cuff-Less Measurement of Blood Pressure Changes in Humans.
    Natarajan K; Block RC; Yavarimanesh M; Chandrasekhar A; Mestha LK; Inan OT; Hahn JO; Mukkamala R
    IEEE Trans Biomed Eng; 2022 Jan; 69(1):53-62. PubMed ID: 34097603
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Continual Learning for Cuffless Blood Pressure Measurement using PPG and ECG Signals.
    Zhang C; Shen Z; Ding X
    Annu Int Conf IEEE Eng Med Biol Soc; 2023 Jul; 2023():1-4. PubMed ID: 38083321
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cuff-less blood pressure estimation from photoplethysmography signal and electrocardiogram.
    Yao LP; Pan ZL
    Phys Eng Sci Med; 2021 Jun; 44(2):397-408. PubMed ID: 33738778
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Features from the photoplethysmogram and the electrocardiogram for estimating changes in blood pressure.
    Finnegan E; Davidson S; Harford M; Watkinson P; Tarassenko L; Villarroel M
    Sci Rep; 2023 Jan; 13(1):986. PubMed ID: 36653426
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches.
    Khalid SG; Zhang J; Chen F; Zheng D
    J Healthc Eng; 2018; 2018():1548647. PubMed ID: 30425819
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Real-Time Cuffless Continuous Blood Pressure Estimation Using 1D Squeeze U-Net Model: A Progress toward mHealth.
    Athaya T; Choi S
    Biosensors (Basel); 2022 Aug; 12(8):. PubMed ID: 36005051
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effects of cuff inflation and deflation on pulse transit time measured from ECG and multi-wavelength PPG.
    Liu J; Li Y; Ding XR; Dai WX; Zhang YT
    Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():5973-6. PubMed ID: 26737652
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.