  • 1. Mechanistic modeling of cation exchange chromatography scale-up considering packing inhomogeneities.
    Koch J; Scheps D; Gunne M; Boscheinen O; Frech C
    J Sep Sci; 2023 May; 46(9):e2300031. PubMed ID: 36846902
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mechanistic modeling and simulation of a complex low and high loading elution behavior of a polypeptide in cation exchange chromatography.
    Koch J; Scheps D; Gunne M; Boscheinen O; Hafner M; Frech C
    J Sep Sci; 2022 Jun; 45(12):2008-2023. PubMed ID: 35332679
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Anti-Langmuir elution behavior of a bispecific monoclonal antibody in cation exchange chromatography: Mechanistic modeling using a pH-dependent Self-Association Steric Mass Action isotherm.
    Seelinger F; Wittkopp F; von Hirschheydt T; Frech C
    J Chromatogr A; 2023 Jan; 1689():463730. PubMed ID: 36592480
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Isotherm model discrimination for multimodal chromatography using mechanistic models derived from high-throughput batch isotherm data.
    Altern SH; Welsh JP; Lyall JY; Kocot AJ; Burgess S; Kumar V; Williams C; Lenhoff AM; Cramer SM
    J Chromatogr A; 2023 Mar; 1693():463878. PubMed ID: 36827799
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cross-scale quality assessment of a mechanistic cation exchange chromatography model.
    Saleh D; Wang G; Mueller B; Rischawy F; Kluters S; Studts J; Hubbuch J
    Biotechnol Prog; 2021 Jan; 37(1):e3081. PubMed ID: 32926575
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mechanistic modeling of ion-exchange process chromatography of charge variants of monoclonal antibody products.
    Kumar V; Leweke S; von Lieres E; Rathore AS
    J Chromatogr A; 2015 Dec; 1426():140-53. PubMed ID: 26686559
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An accelerated approach for mechanistic model based prediction of linear gradient elution ion-exchange chromatography of proteins.
    Shekhawat LK; Tiwari A; Yamamoto S; Rathore AS
    J Chromatogr A; 2022 Sep; 1680():463423. PubMed ID: 36001907
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Packing quality, protein binding capacity and separation efficiency of pre-packed columns ranging from 1 mL laboratory to 57 L industrial scale.
    Schweiger S; Berger E; Chan A; Peyser J; Gebski C; Jungbauer A
    J Chromatogr A; 2019 Apr; 1591():79-86. PubMed ID: 30661762
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of differences between dual salt-pH gradient elution and mono gradient elution using a thermodynamic model: Simultaneous separation of six monoclonal antibody charge and size variants on preparative-scale ion exchange chromatographic resin.
    Lee YF; Jöhnck M; Frech C
    Biotechnol Prog; 2018 Jul; 34(4):973-986. PubMed ID: 29464892
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Unfolding and aggregation of a glycosylated monoclonal antibody on a cation exchange column. Part I. Chromatographic elution and batch adsorption behavior.
    Guo J; Zhang S; Carta G
    J Chromatogr A; 2014 Aug; 1356():117-28. PubMed ID: 25015241
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Application of a chromatography model with linear gradient elution experimental data to the rapid scale-up in ion-exchange process chromatography of proteins.
    Ishihara T; Kadoya T; Yamamoto S
    J Chromatogr A; 2007 Aug; 1162(1):34-40. PubMed ID: 17399733
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Simulation of the dynamic packing behavior of preparative chromatography columns via discrete particle modeling.
    Dorn M; Hekmat D
    Biotechnol Prog; 2016 Mar; 32(2):363-71. PubMed ID: 26588806
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Application of the Steric Mass Action formalism for modeling under high loading conditions: Part 1. Investigation of the influence of pH on the steric shielding factor.
    Seelinger F; Wittkopp F; von Hirschheydt T; Hafner M; Frech C
    J Chromatogr A; 2022 Aug; 1676():463265. PubMed ID: 35779394
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Column-to-column packing variation of disposable pre-packed columns for protein chromatography.
    Schweiger S; Hinterberger S; Jungbauer A
    J Chromatogr A; 2017 Dec; 1527():70-79. PubMed ID: 29089107
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prediction of lab and manufacturing scale chromatography performance using mini-columns and mechanistic modeling.
    Benner SW; Welsh JP; Rauscher MA; Pollard JM
    J Chromatogr A; 2019 May; 1593():54-62. PubMed ID: 30739757
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Application of linear pH gradients for the modeling of ion exchange chromatography: Separation of monoclonal antibody monomer from aggregates.
    Kluters S; Wittkopp F; Jöhnck M; Frech C
    J Sep Sci; 2016 Feb; 39(4):663-75. PubMed ID: 26549715
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Are axial and radial flow chromatography different?
    Besselink T; van der Padt A; Janssen AE; Boom RM
    J Chromatogr A; 2013 Jan; 1271(1):105-14. PubMed ID: 23228917
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Analysis of complex protein elution behavior in preparative ion exchange processes using a colloidal particle adsorption model.
    Briskot T; Hahn T; Huuk T; Wang G; Kluters S; Studts J; Wittkopp F; Winderl J; Schwan P; Hagemann I; Kaiser K; Trapp A; Stamm SM; Koehn J; Malmquist G; Hubbuch J
    J Chromatogr A; 2021 Sep; 1654():462439. PubMed ID: 34384923
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Tuning selectivity in cation-exchange chromatography applied for monoclonal antibody separations, part 2: Evaluation of recent stationary phases.
    Murisier A; Farsang E; Horváth K; Lauber M; Beck A; Guillarme D; Fekete S
    J Pharm Biomed Anal; 2019 Aug; 172():320-328. PubMed ID: 31085394
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Systematic Interpolation Method Predicts Antibody Monomer-Dimer Separation by Gradient Elution Chromatography at High Protein Loads.
    Creasy A; Reck J; Pabst T; Hunter A; Barker G; Carta G
    Biotechnol J; 2019 Mar; 14(3):e1800132. PubMed ID: 29809318
    [TBL] [Abstract][Full Text] [Related]  