BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 36848674)

  • 1. A feasibility study of enhanced prompt gamma imaging for range verification in proton therapy using deep learning.
    Jiang Z; Polf JC; Barajas CA; Gobbert MK; Ren L
    Phys Med Biol; 2023 Mar; 68(7):. PubMed ID: 36848674
    [No Abstract]   [Full Text] [Related]  

  • 2. Imaging of prompt gamma rays emitted during delivery of clinical proton beams with a Compton camera: feasibility studies for range verification.
    Polf JC; Avery S; Mackin DS; Beddar S
    Phys Med Biol; 2015 Sep; 60(18):7085-99. PubMed ID: 26317610
    [TBL] [Abstract][Full Text] [Related]  

  • 3. 3D prompt gamma imaging for proton beam range verification.
    Draeger E; Mackin D; Peterson S; Chen H; Avery S; Beddar S; Polf JC
    Phys Med Biol; 2018 Jan; 63(3):035019. PubMed ID: 29380750
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A deep learning approach for converting prompt gamma images to proton dose distributions: A Monte Carlo simulation study.
    Liu CC; Huang HM
    Phys Med; 2020 Jan; 69():110-119. PubMed ID: 31869575
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Machine learning approach for proton range verification using real-time prompt gamma imaging with Compton cameras: addressing the total deposited energy information gap.
    Kazemi Kozani M
    Phys Med Biol; 2024 Mar; 69(7):. PubMed ID: 38417182
    [No Abstract]   [Full Text] [Related]  

  • 6. Comparison of reconstructed prompt gamma emissions using maximum likelihood estimation and origin ensemble algorithms for a Compton camera system tailored to proton range monitoring.
    Valencia Lozano I; Dedes G; Peterson S; Mackin D; Zoglauer A; Beddar S; Avery S; Polf J; Parodi K
    Z Med Phys; 2023 May; 33(2):124-134. PubMed ID: 35750591
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Applications of Machine Learning to Improve the Clinical Viability of Compton Camera Based
    Polf JC; Barajas CA; Peterson SW; Mackin DS; Beddar S; Ren L; Gobbert MK
    Front Phys; 2022 Apr; 10():. PubMed ID: 36119562
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Computational model for detector timing effects in Compton-camera based prompt-gamma imaging for proton radiotherapy.
    Maggi P; Peterson S; Panthi R; Mackin D; Yang H; He Z; Beddar S; Polf J
    Phys Med Biol; 2020 Jun; 65(12):125004. PubMed ID: 32320971
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accounting for prompt gamma emission and detection for range verification in proton therapy treatment planning.
    Tian L; Huang Z; Janssens G; Landry G; Dedes G; Kamp F; Belka C; Pinto M; Parodi K
    Phys Med Biol; 2021 Feb; 66(5):055005. PubMed ID: 33171445
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of a stochastic reconstruction algorithm for use in Compton camera imaging and beam range verification from secondary gamma emission during proton therapy.
    Mackin D; Peterson S; Beddar S; Polf J
    Phys Med Biol; 2012 Jun; 57(11):3537-53. PubMed ID: 22588144
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A low-count reconstruction algorithm for Compton-based prompt gamma imaging.
    Huang HM; Liu CC; Jan ML; Lee MW
    Phys Med Biol; 2018 Apr; 63(8):085013. PubMed ID: 29546850
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Detecting prompt gamma emission during proton therapy: the effects of detector size and distance from the patient.
    Polf JC; Mackin D; Lee E; Avery S; Beddar S
    Phys Med Biol; 2014 May; 59(9):2325-40. PubMed ID: 24732052
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new treatment planning approach accounting for prompt gamma range verification and interfractional anatomical changes.
    Tian L; Landry G; Dedes G; Pinto M; Kamp F; Belka C; Parodi K
    Phys Med Biol; 2020 Apr; 65(9):095005. PubMed ID: 32135530
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monte Carlo patient study on the comparison of prompt gamma and PET imaging for range verification in proton therapy.
    Moteabbed M; España S; Paganetti H
    Phys Med Biol; 2011 Feb; 56(4):1063-82. PubMed ID: 21263174
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Proton therapy monitoring by Compton imaging: influence of the large energy spectrum of the prompt-γ radiation.
    Hilaire E; Sarrut D; Peyrin F; Maxim V
    Phys Med Biol; 2016 Apr; 61(8):3127-46. PubMed ID: 27008459
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Use of a LYSO-based Compton camera for prompt gamma range verification in proton therapy.
    Jan ML; Hsiao IT; Huang HM
    Med Phys; 2017 Dec; 44(12):6261-6269. PubMed ID: 29031024
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Compton-based prompt gamma imaging using ordered origin ensemble algorithm with resolution recovery in proton therapy.
    Yao Z; Xiao Y; Chen Z; Wang B; Hou Q
    Sci Rep; 2019 Feb; 9(1):1133. PubMed ID: 30718671
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Design and performance evaluation of a slit-slat camera for 2D prompt gamma imaging in proton therapy monitoring: A Monte Carlo simulation study.
    Malekzadeh E; Rajabi H; Tajik-Mansoury MA; Sabouri P; Fiorina E; Kalantari F
    Med Phys; 2023 Jun; 50(6):3701-3718. PubMed ID: 36718592
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Toward a new treatment planning approach accounting for in vivo proton range verification.
    Tian L; Landry G; Dedes G; Kamp F; Pinto M; Niepel K; Belka C; Parodi K
    Phys Med Biol; 2018 Oct; 63(21):215025. PubMed ID: 30375361
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Millisecond speed deep learning based proton dose calculation with Monte Carlo accuracy.
    Pastor-Serrano O; Perkó Z
    Phys Med Biol; 2022 May; 67(10):. PubMed ID: 35447605
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.