BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 36850959)

  • 1. Design and Performance Verification of a Novel RCM Mechanism for a Minimally Invasive Surgical Robot.
    Shi H; Liang Z; Zhang B; Wang H
    Sensors (Basel); 2023 Feb; 23(4):. PubMed ID: 36850959
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Design of a new haptic device and experiments in minimally invasive surgical robot.
    Wang T; Pan B; Fu Y; Wang S; Ai Y
    Comput Assist Surg (Abingdon); 2017 Dec; 22(sup1):240-250. PubMed ID: 29072504
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Concurrent Framework for Constrained Inverse Kinematics of Minimally Invasive Surgical Robots.
    Colan J; Davila A; Fozilov K; Hasegawa Y
    Sensors (Basel); 2023 Mar; 23(6):. PubMed ID: 36992038
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Control design and implementation of a novel master-slave surgery robot system, MicroHand A.
    Sang H; Wang S; Li J; He C; Zhang L; Wang X
    Int J Med Robot; 2011 Sep; 7(3):334-47. PubMed ID: 21732498
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Kinematic design considerations for minimally invasive surgical robots: an overview.
    Kuo CH; Dai JS; Dasgupta P
    Int J Med Robot; 2012 Jun; 8(2):127-45. PubMed ID: 22228671
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A novel compliant surgical robot: Preliminary design analysis.
    Kapsalyamov A; Hussain S; Jamwal PK
    Math Biosci Eng; 2019 Dec; 17(3):1944-1958. PubMed ID: 32233517
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development of the SAIT single-port surgical access robot--slave arm based on RCM mechanism.
    Roh SG; Lee Y; Lee J; Ha T; Sang T; Moon KW; Lee M; Choi JY
    Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():5285-90. PubMed ID: 26737484
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A novel remote center of motion mechanism for the force-reflective master robot of haptic tele-surgery systems.
    Hadavand M; Mirbagheri A; Behzadipour S; Farahmand F
    Int J Med Robot; 2014 Jun; 10(2):129-39. PubMed ID: 23733681
    [TBL] [Abstract][Full Text] [Related]  

  • 9. New remote centre of motion mechanism for robot-assisted minimally invasive surgery.
    Zhou X; Zhang H; Feng M; Zhao J; Fu Y
    Biomed Eng Online; 2018 Nov; 17(1):170. PubMed ID: 30453983
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Design of a force-reflective master robot for haptic telesurgery applications: RoboMaster1.
    Hadavand M; Mirbagheri A; Salarieh H; Farahmand F
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():7037-40. PubMed ID: 22255959
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of a medical robot system for minimally invasive surgery.
    Feng M; Fu Y; Pan B; Liu C
    Int J Med Robot; 2012 Mar; 8(1):85-96. PubMed ID: 21990214
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hamlyn CRM: a compact master manipulator for surgical robot remote control.
    Zhang D; Liu J; Zhang L; Yang GZ
    Int J Comput Assist Radiol Surg; 2020 Mar; 15(3):503-514. PubMed ID: 31956954
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A master manipulator with a remote-center-of-motion kinematic structure for a minimally invasive robotic surgical system.
    Lee H; Cheon B; Hwang M; Kang D; Kwon DS
    Int J Med Robot; 2018 Feb; 14(1):. PubMed ID: 29027359
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Specifying Inputs for the Computational Structure of a Surgical System via Optical Method and DLT Algorithm Based on In Vitro Experiments on Cardiovascular Tissue in Minimally Invasive and Robotic Surgery.
    Ilewicz G; Ładyżyńska-Kozdraś E
    Sensors (Basel); 2022 Mar; 22(6):. PubMed ID: 35336506
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Estimation of optimal pivot point for remote center of motion alignment in surgery.
    Rosa B; Gruijthuijsen C; Van Cleynenbreugel B; Sloten JV; Reynaerts D; Poorten EV
    Int J Comput Assist Radiol Surg; 2015 Feb; 10(2):205-15. PubMed ID: 24830535
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Design, Control, and Experiments of a Novel Robotic Uterine Manipulator With the Motorized 3-DoF Manipulation Rod.
    Wu J; Wang T; Guo H; Wang Y; Guo D; Lu B; Wang Z; Zhong F; Wang H; Yuan J; Li Y; Cheung TH; Wang Y; Liu YH
    IEEE Trans Biomed Eng; 2023 Jul; 70(7):2203-2214. PubMed ID: 37022424
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Design of an integrated master-slave robotic system for minimally invasive surgery.
    Li J; Zhou N; Wang S; Gao Y; Liu D
    Int J Med Robot; 2012 Mar; 8(1):77-84. PubMed ID: 21984343
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Realization of Force Detection and Feedback Control for Slave Manipulator of Master/Slave Surgical Robot.
    Shi H; Zhang B; Mei X; Song Q
    Sensors (Basel); 2021 Nov; 21(22):. PubMed ID: 34833581
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Realization and Control of Robotic Injection Prototype With Instantaneous Remote Center of Motion Mechanism.
    Liu L; Chen W; Chen Z; Zhou W; Wei R; Liu Y
    IEEE Trans Biomed Eng; 2024 Feb; 71(2):433-445. PubMed ID: 37594869
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Open core control software for surgical robots.
    Arata J; Kozuka H; Kim HW; Takesue N; Vladimirov B; Sakaguchi M; Tokuda J; Hata N; Chinzei K; Fujimoto H
    Int J Comput Assist Radiol Surg; 2010 May; 5(3):211-20. PubMed ID: 20033506
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.