126 related articles for article (PubMed ID: 36856282)
1. Large Versus Small Opening Wedge High Tibial Osteotomies Performed With a Protective Wire Over the Lateral Hinge: Incidence of Lateral Hinge Fracture and Early Clinical Outcomes.
Koh DTS; Soong J; Yeo W; Tan MWP; Teo SJ; Wilson A; Lee KH
Am J Sports Med; 2023 Mar; 51(3):672-677. PubMed ID: 36856282
[TBL] [Abstract][Full Text] [Related]
2. Hinge Fractures Are Underestimated on Plain Radiographs After Open Wedge Proximal Tibial Osteotomy: Evaluation by Computed Tomography.
Lee BS; Jo BK; Bin SI; Kim JM; Lee CR; Kwon YH
Am J Sports Med; 2019 May; 47(6):1370-1375. PubMed ID: 30986094
[TBL] [Abstract][Full Text] [Related]
3. Early experience of lateral hinge fracture during medial opening-wedge high tibial osteotomy: incidence and clinical outcomes.
Song KY; Koh IJ; Kim MS; Choi NY; Jeong JH; In Y
Arch Orthop Trauma Surg; 2020 Feb; 140(2):161-169. PubMed ID: 31273455
[TBL] [Abstract][Full Text] [Related]
4. Computed Tomography Detects Hinge Fractures After Medial Opening Wedge High Tibial Osteotomy: A Systematic Review.
Kim JH; Lee DK; Park YB
Arthroscopy; 2021 Apr; 37(4):1337-1352. PubMed ID: 33242632
[TBL] [Abstract][Full Text] [Related]
5. A protective hinge wire, intersecting the osteotomy plane, can reduce the occurrence of perioperative hinge fractures in medial opening wedge osteotomy.
Gulagaci F; Jacquet C; Ehlinger M; Sharma A; Kley K; Wilson A; Parratte S; Ollivier M
Knee Surg Sports Traumatol Arthrosc; 2020 Oct; 28(10):3173-3182. PubMed ID: 31773202
[TBL] [Abstract][Full Text] [Related]
6. Uniplane medial opening wedge high tibial osteotomy relative to a biplane osteotomy can reduce the incidence of lateral-hinge fracture.
Nha KW; Shin MJ; Suh DW; Nam YJ; Kim KS; Kyung BS
Knee Surg Sports Traumatol Arthrosc; 2020 May; 28(5):1436-1444. PubMed ID: 31069445
[TBL] [Abstract][Full Text] [Related]
7. Does a lateral tibial plateau fracture (Takeuchi type III) occuring during opening wedge high tibial osteotomy induce a higher revision rate to total knee arthroplasty.
Giardini P; De Luca L; Crespan B; Christodoulidis A; Molinari M
Acta Biomed; 2022 Mar; 92(S3):e2021558. PubMed ID: 35604265
[TBL] [Abstract][Full Text] [Related]
8. Lateral Distance From the Osteotomy Hinge Point to the Tibial Cortex Is Associated With Lateral Hinge Fracture Type and Fracture Occurrence Time After Medial Open-Wedge High Tibial Osteotomy.
Kim SM; Bin SI; Kim JM; Lee BS; Lee HY; Lee SJ
Arthroscopy; 2024 Mar; 40(3):890-895. PubMed ID: 37586667
[TBL] [Abstract][Full Text] [Related]
9. Prediction and Development of Preventive Strategies for Lateral Hinge Fracture During Opening Wedge High Tibial Osteotomy Based on Osteotomy Configurations.
Choi HG; Kim JS; Jung YS; Yoo HJ; Lee YS
Am J Sports Med; 2021 Sep; 49(11):2942-2954. PubMed ID: 34328812
[TBL] [Abstract][Full Text] [Related]
10. Biomechanical effect of a lateral hinge fracture for a medial opening wedge high tibial osteotomy: finite element study.
Kang KT; Koh YG; Lee JA; Lee JJ; Kwon SK
J Orthop Surg Res; 2020 Feb; 15(1):63. PubMed ID: 32085786
[TBL] [Abstract][Full Text] [Related]
11. Experimental investigation of the risk of lateral cortex fracture during valgus tibial osteotomy.
Didier A; Favreau H; Ollivier M; Jmal H; Bonnomet F; Bahlouli N; Martz P; Ehlinger M
Orthop Traumatol Surg Res; 2022 Dec; 108(8):103428. PubMed ID: 36202319
[TBL] [Abstract][Full Text] [Related]
12. [Early effectiveness analysis of lateral hinge fracture during medial opening-wedge high tibial osteotomy].
Wu M; Wang Z; Zhou P; Zhang K; Chen X; Xiao Y; Guan J
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2020 Jul; 34(7):854-861. PubMed ID: 32666728
[TBL] [Abstract][Full Text] [Related]
13. Incidence and risk factors for lateral hinge fractures in medial opening wedge high tibial osteotomy and medial opening wedge distal tibial tuberosity osteotomy.
Ogawa H; Nakamura Y; Matsumoto K; Akiyama H
Knee; 2023 Oct; 44():245-252. PubMed ID: 37683510
[TBL] [Abstract][Full Text] [Related]
14. Incidence and Predictors of Lateral Hinge Fractures Following Medial Opening-Wedge High Tibial Osteotomy Using Locking Plate System: Better Performance of Computed Tomography Scans.
Han SB; Choi JH; Mahajan A; Shin YS
J Arthroplasty; 2019 May; 34(5):846-851. PubMed ID: 30733072
[TBL] [Abstract][Full Text] [Related]
15. Effect of lateral hinge fractures for bone union and clinical outcomes following opening-wedge distal tibial tubercle osteotomy in comparison with opening-wedge high tibial osteotomy.
Otsuki S; Ikeda K; Ishitani T; Okamoto Y; Wakama H; Neo M
J Exp Orthop; 2023 Dec; 10(1):140. PubMed ID: 38095818
[TBL] [Abstract][Full Text] [Related]
16. Retro-tubercular gap widening can be caused by inappropriate anterior osteotomy and large opening gap in the medial biplanar open-wedge HTO.
Jo IH; Lee OS; Lee SH; Kim KW; Lee YS
Knee Surg Sports Traumatol Arthrosc; 2019 Sep; 27(9):2910-2916. PubMed ID: 29804186
[TBL] [Abstract][Full Text] [Related]
17. Diagnostic Value of Computed Tomography and Risk Factors for Lateral Hinge Fracture in the Open Wedge High Tibial Osteotomy.
Lee OS; Lee YS
Arthroscopy; 2018 Apr; 34(4):1032-1043. PubMed ID: 29229417
[TBL] [Abstract][Full Text] [Related]
18. Predictive Factors for and Detection of Lateral Hinge Fractures Following Open Wedge High Tibial Osteotomy: Plain Radiography Versus Computed Tomography.
Lee SS; Celik H; Lee DH
Arthroscopy; 2018 Nov; 34(11):3073-3079. PubMed ID: 30292595
[TBL] [Abstract][Full Text] [Related]
19. Opening-Wedge High Tibial Osteotomy With High Hinge Position Risks Lateral Hinge Fracture in Men With Posterolateral Tibial Condyle Protrusion.
Morita Y; Kuriyama S; Yamawaki Y; Nakamura S; Nishitani K; Ito H; Matsuda S
Arthroscopy; 2023 Feb; 39(2):324-334. PubMed ID: 35961443
[TBL] [Abstract][Full Text] [Related]
20. Extra-articular Lateral Hinge Fracture Does Not Affect the Outcomes in Medial Open-Wedge High Tibial Osteotomy Using a Locked Plate System.
Kim KI; Kim GB; Kim HJ; Lee SH; Yoon WK
Arthroscopy; 2018 Dec; 34(12):3246-3255. PubMed ID: 30396798
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]