These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 36856326)

  • 1. Analytic prediction of droplet vaporization events to estimate the precision of ultrasound-based proton range verification.
    Collado-Lara G; Heymans SV; Rovituso M; Sterpin E; D'hooge J; Vos HJ; Abeele KVD; de Jong N
    Med Phys; 2023 Jul; 50(7):4562-4577. PubMed ID: 36856326
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Spatiotemporal Distribution of Nanodroplet Vaporization in a Proton Beam Using Real-Time Ultrasound Imaging for Range Verification.
    Collado-Lara G; Heymans SV; Rovituso M; Carlier B; Toumia Y; Verweij M; Paradossi G; Sterpin E; Vos HJ; D'hooge J; de Jong N; Van Den Abeele K; Daeichin V
    Ultrasound Med Biol; 2022 Jan; 48(1):149-156. PubMed ID: 34629191
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Modulating ultrasound contrast generation from injectable nanodroplets for proton range verification by varying the degree of superheat.
    Heymans SV; Carlier B; Toumia Y; Nooijens S; Ingram M; Giammanco A; d'Agostino E; Crijns W; Bertrand A; Paradossi G; Himmelreich U; D'hooge J; Sterpin E; Van Den Abeele K
    Med Phys; 2021 Apr; 48(4):1983-1995. PubMed ID: 33587754
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Proton range verification with ultrasound imaging using injectable radiation sensitive nanodroplets: a feasibility study.
    Carlier B; Heymans SV; Nooijens S; Toumia Y; Ingram M; Paradossi G; D'Agostino E; Himmelreich U; D'hooge J; Van Den Abeele K; Sterpin E
    Phys Med Biol; 2020 Mar; 65(6):065013. PubMed ID: 32045902
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Deep learning for dose assessment in radiotherapy by the super-localization of vaporized nanodroplets in high frame rate ultrasound imaging.
    van der Heyden B; Heymans SV; Carlier B; Collado-Lara G; Sterpin E; D'hooge J
    Phys Med Biol; 2022 May; 67(11):. PubMed ID: 35508145
    [No Abstract]   [Full Text] [Related]  

  • 6. Acoustic Modulation Enables Proton Detection With Nanodroplets at Body Temperature.
    Heymans SV; Collado-Lara G; Rovituso M; Vos HJ; D'hooge J; de Jong N; Van Abeele KD
    IEEE Trans Ultrason Ferroelectr Freq Control; 2022 Jun; 69(6):2028-2038. PubMed ID: 35385380
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields.
    Padilla-Cabal F; Alejandro Fragoso J; Franz Resch A; Georg D; Fuchs H
    Med Phys; 2020 Jan; 47(1):223-233. PubMed ID: 31661559
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A feasibility study of enhanced prompt gamma imaging for range verification in proton therapy using deep learning.
    Jiang Z; Polf JC; Barajas CA; Gobbert MK; Ren L
    Phys Med Biol; 2023 Mar; 68(7):. PubMed ID: 36848674
    [No Abstract]   [Full Text] [Related]  

  • 9. A full-scale clinical prototype for proton range verification using prompt gamma-ray spectroscopy.
    Hueso-González F; Rabe M; Ruggieri TA; Bortfeld T; Verburg JM
    Phys Med Biol; 2018 Sep; 63(18):185019. PubMed ID: 30033938
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An analytical dose-averaged LET calculation algorithm considering the off-axis LET enhancement by secondary protons for spot-scanning proton therapy.
    Hirayama S; Matsuura T; Ueda H; Fujii Y; Fujii T; Takao S; Miyamoto N; Shimizu S; Fujimoto R; Umegaki K; Shirato H
    Med Phys; 2018 Jul; 45(7):3404-3416. PubMed ID: 29788552
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Design and performance evaluation of a slit-slat camera for 2D prompt gamma imaging in proton therapy monitoring: A Monte Carlo simulation study.
    Malekzadeh E; Rajabi H; Tajik-Mansoury MA; Sabouri P; Fiorina E; Kalantari F
    Med Phys; 2023 Jun; 50(6):3701-3718. PubMed ID: 36718592
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Stopping power and range estimations in proton therapy based on prompt gamma timing: motion models and automated parameter optimization.
    Werner J; Pennazio F; Schmid N; Fiorina E; Bersani D; Cerello P; Kasprzak J; Mosco N; Ranjbar S; Sacchi R; Ferrero V; Rafecas M
    Phys Med Biol; 2024 Jul; 69(14):. PubMed ID: 38941994
    [No Abstract]   [Full Text] [Related]  

  • 13. Impact of secondary particles on the magnetic field generated by a proton pencil beam: a finite-element analysis based on Geant4-DNA simulations.
    Rädler M; Buizza G; Kawula M; Palaniappan P; Gianoli C; Baroni G; Paganelli C; Parodi K; Riboldi M
    Med Phys; 2023 Feb; 50(2):1000-1018. PubMed ID: 36346042
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A pencil beam algorithm for magnetic resonance image-guided proton therapy.
    Padilla-Cabal F; Georg D; Fuchs H
    Med Phys; 2018 May; 45(5):2195-2204. PubMed ID: 29532490
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Monte Carlo feasibility study for neutron based real-time range verification in proton therapy.
    Ytre-Hauge KS; Skjerdal K; Mattingly J; Meric I
    Sci Rep; 2019 Feb; 9(1):2011. PubMed ID: 30765808
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Range shift verification in spot scanning proton therapy using gamma electron vertex imaging.
    Kim SH; Jeong JH; Ku Y; Lee SB; Shin D; Lim YK; Kim H; Kim CH
    Med Phys; 2024 Mar; 51(3):1985-1996. PubMed ID: 37722712
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Range verification of a clinical proton beam in an abdominal phantom by co-registration of ionoacoustics and ultrasound.
    Schauer J; Wieser HP; Lascaud J; Huang Y; Vidal M; Herault J; Ntziachristos V; Dollinger G; Parodi K
    Phys Med Biol; 2023 Jun; 68(12):. PubMed ID: 37220766
    [No Abstract]   [Full Text] [Related]  

  • 18. Optimization of FLASH proton beams using a track-repeating algorithm.
    Wang Q; Titt U; Mohan R; Guan F; Zhao Y; Yang M; Yepes P
    Med Phys; 2022 Oct; 49(10):6684-6698. PubMed ID: 35900902
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Toward a new treatment planning approach accounting for in vivo proton range verification.
    Tian L; Landry G; Dedes G; Kamp F; Pinto M; Niepel K; Belka C; Parodi K
    Phys Med Biol; 2018 Oct; 63(21):215025. PubMed ID: 30375361
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Preliminary Investigation of Radiation-Sensitive Ultrasound Contrast Agents for Photon Dosimetry.
    Carlier B; Heymans SV; Nooijens S; Collado-Lara G; Toumia Y; Delombaerde L; Paradossi G; D'hooge J; Van Den Abeele K; Sterpin E; Himmelreich U
    Pharmaceuticals (Basel); 2024 May; 17(5):. PubMed ID: 38794199
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]