These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 36859012)

  • 1. Invited article: X-ray phase contrast imaging in inertial confinement fusion and high energy density research.
    Montgomery DS
    Rev Sci Instrum; 2023 Feb; 94(2):021103. PubMed ID: 36859012
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multi-frame, ultrafast, x-ray microscope for imaging shockwave dynamics.
    Hodge DS; Leong AFT; Pandolfi S; Kurzer-Ogul K; Montgomery DS; Aluie H; Bolme C; Carver T; Cunningham E; Curry CB; Dayton M; Decker FJ; Galtier E; Hart P; Khaghani D; Ja Lee H; Li K; Liu Y; Ramos K; Shang J; Vetter S; Nagler B; Sandberg RL; Gleason AE
    Opt Express; 2022 Oct; 30(21):38405-38422. PubMed ID: 36258406
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quantitative phase contrast imaging of a shock-wave with a laser-plasma based X-ray source.
    Barbato F; Atzeni S; Batani D; Bleiner D; Boutoux G; Brabetz C; Bradford P; Mancelli D; Neumayer P; Schiavi A; Trela J; Volpe L; Zeraouli G; Woolsey N; Antonelli L
    Sci Rep; 2019 Dec; 9(1):18805. PubMed ID: 31827132
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An x-ray optic calibration facility for high energy density diagnostics.
    Kozioziemski BJ; Ayers J; Bell P; Bradley DK; Descalle MA; Hau-Riege S; McCarville TJ; Pardini T; Pickworth LA; Vogel JK; Stone J; Robinson J; Ampleford DJ; Ball CR; Bourdon CJ; Fein JR; Wu M; Ames A; Bruni R; Romaine S
    Rev Sci Instrum; 2018 Oct; 89(10):10G112. PubMed ID: 30399878
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Phase-contrast imaging using ultrafast x-rays in laser-shocked materials.
    Workman J; Cobble J; Flippo K; Gautier DC; Montgomery DS; Offermann DT
    Rev Sci Instrum; 2010 Oct; 81(10):10E520. PubMed ID: 21034048
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development of optics for x-ray phase-contrast imaging of high energy density plasmas.
    Stutman D; Finkenthal M; Moldovan N
    Rev Sci Instrum; 2010 Oct; 81(10):10E504. PubMed ID: 21034032
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Direct Conversion X-ray Detector with Micron-Scale Pixel Pitch for Edge-Illumination and Propagation-Based X-ray Phase-Contrast Imaging.
    Pil-Ali A; Adnani S; Scott CC; Karim KS
    Sensors (Basel); 2022 Aug; 22(15):. PubMed ID: 35957449
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Phase-contrast imaging with a compact x-ray light source: system design.
    Sung Y; Gupta R; Nelson B; Leng S; McCollough CH; Graves WS
    J Med Imaging (Bellingham); 2017 Oct; 4(4):043503. PubMed ID: 29201939
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In-Line Phase-Contrast X-ray Imaging and Tomography for Materials Science.
    Mayo SC; Stevenson AW; Wilkins SW
    Materials (Basel); 2012 May; 5(5):937-965. PubMed ID: 28817018
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Large field of view, fast and low dose multimodal phase-contrast imaging at high x-ray energy.
    Astolfo A; Endrizzi M; Vittoria FA; Diemoz PC; Price B; Haig I; Olivo A
    Sci Rep; 2017 May; 7(1):2187. PubMed ID: 28526835
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The achievable resolution for X-ray imaging of cells and other soft biological material.
    Nave C
    IUCrJ; 2020 May; 7(Pt 3):393-403. PubMed ID: 32431823
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Refraction-enhanced backlit imaging of axially symmetric inertial confinement fusion plasmas.
    Koch JA; Landen OL; Suter LJ; Masse LP; Clark DS; Ross JS; Mackinnon AJ; Meezan NB; Thomas CA; Ping Y
    Appl Opt; 2013 May; 52(15):3538-56. PubMed ID: 23736240
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Design of a novel phase contrast x-ray imaging system for mammography.
    Munro PR; Ignatyev K; Speller RD; Olivo A
    Phys Med Biol; 2010 Jul; 55(14):4169-85. PubMed ID: 20601778
    [TBL] [Abstract][Full Text] [Related]  

  • 14. X-ray backlighter requirements for refraction-based electron density diagnostics through Talbot-Lau deflectometry.
    Valdivia MP; Veloso F; Stutman D; Stoeckl C; Mileham C; Begishev IA; Theobald W; Vescovi M; Useche W; Regan SP; Albertazzi B; Rigon G; Mabey P; Michel T; Pikuz SA; Koenig M; Casner A
    Rev Sci Instrum; 2018 Oct; 89(10):10G127. PubMed ID: 30399908
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Source size and temporal coherence requirements of coded aperture type x-ray phase contrast imaging systems.
    Munro PR; Ignatyev K; Speller RD; Olivo A
    Opt Express; 2010 Sep; 18(19):19681-92. PubMed ID: 20940863
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Theory and preliminary experimental verification of quantitative edge illumination x-ray phase contrast tomography.
    Hagen CK; Diemoz PC; Endrizzi M; Rigon L; Dreossi D; Arfelli F; Lopez FC; Longo R; Olivo A
    Opt Express; 2014 Apr; 22(7):7989-8000. PubMed ID: 24718174
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Self-aligned multi-layer X-ray absorption grating using large-area fabrication methods for X-ray phase-contrast imaging.
    Pil-Ali A; Adnani S; Karim KS
    Sci Rep; 2023 Feb; 13(1):2508. PubMed ID: 36781907
    [TBL] [Abstract][Full Text] [Related]  

  • 18. X-ray phase contrast imaging of spherical capsules.
    Fourmaux S; Hallin E; Krol A; Bourgade JL; Kieffer JC
    Opt Express; 2020 Apr; 28(9):13978-13990. PubMed ID: 32403862
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fluence adaptation for contrast-based dose optimization in x-ray phase-contrast imaging.
    Wu C; Xing Y; Zhang L; Chen Z; Zhu X; Zhang X; Gao H
    Med Phys; 2021 Oct; 48(10):6106-6120. PubMed ID: 34432891
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Moiré deflectometry using the Talbot-Lau interferometer as refraction diagnostic for high energy density plasmas at energies below 10 keV.
    Valdivia MP; Stutman D; Finkenthal M
    Rev Sci Instrum; 2014 Jul; 85(7):073702. PubMed ID: 25085141
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.