These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 36859028)

  • 1. Acoustic emission detection of micro-cracks under high pressure and high temperature in a deformation large-volume apparatus at the endstation P61B, PETRA III.
    Ma S; Gasc J; Farla R
    Rev Sci Instrum; 2023 Feb; 94(2):023901. PubMed ID: 36859028
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Extreme conditions research using the large-volume press at the P61B endstation, PETRA III.
    Farla R; Bhat S; Sonntag S; Chanyshev A; Ma S; Ishii T; Liu Z; Néri A; Nishiyama N; Faria GA; Wroblewski T; Schulte-Schrepping H; Drube W; Seeck O; Katsura T
    J Synchrotron Radiat; 2022 Mar; 29(Pt 2):409-423. PubMed ID: 35254304
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The large volume press facility at ID06 beamline of the European synchrotron radiation facility as a High Pressure-High Temperature deformation apparatus.
    Guignard J; Crichton WA
    Rev Sci Instrum; 2015 Aug; 86(8):085112. PubMed ID: 26329238
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Stress Distribution During Cold Compression of Rocks and Mineral Aggregates Using Synchrotron-based X-Ray Diffraction.
    Cheung CSN; Weidner DJ; Li L; Meredith PG; Chen H; Whitaker M; Chen X
    J Vis Exp; 2018 May; (135):. PubMed ID: 29863676
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A combination of a Drickamer anvil apparatus and monochromatic X-rays for stress and strain measurements under high pressure.
    Nishiyama N; Wang Y; Irifune T; Sanehira T; Rivers ML; Sutton SR; Cookson D
    J Synchrotron Radiat; 2009 Nov; 16(Pt 6):742-7. PubMed ID: 19844008
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An improved setup for radial diffraction experiments at high pressures and high temperatures in a resistive graphite-heated diamond anvil cell.
    Immoor J; Marquardt H; Miyagi L; Speziale S; Merkel S; Schwark I; Ehnes A; Liermann HP
    Rev Sci Instrum; 2020 Apr; 91(4):045121. PubMed ID: 32357741
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of Acoustic Emission and Pattern Recognition for Crack Detection of a Large Carbide Anvil.
    Chen B; Wang Y; Yan Z
    Sensors (Basel); 2018 Jan; 18(2):. PubMed ID: 29382144
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Macquarie Deformation-DIA facility at the Australian Synchrotron: A tool for high-pressure, high-temperature experiments with synchrotron radiation.
    Farmer N; Rushmer T; Wykes J; Mallmann G
    Rev Sci Instrum; 2020 Nov; 91(11):114501. PubMed ID: 33261430
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Deformation T-Cup: a new multi-anvil apparatus for controlled strain-rate deformation experiments at pressures above 18 GPa.
    Hunt SA; Weidner DJ; McCormack RJ; Whitaker ML; Bailey E; Li L; Vaughan MT; Dobson DP
    Rev Sci Instrum; 2014 Aug; 85(8):085103. PubMed ID: 25173308
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Acoustic properties of fracture of dental restorative materials and endocrown restorations under quasi-static loading.
    Skalskyi V; Makeev V; Stankevych O; Dubytskyi O
    Dent Mater; 2020 May; 36(5):617-625. PubMed ID: 32299664
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Acoustic detection of cracks in the anvil of a large-volume cubic high-pressure apparatus.
    Yan Z; Chen B; Tian H; Cheng X; Yang J
    Rev Sci Instrum; 2015 Dec; 86(12):124904. PubMed ID: 26724059
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A resistively-heated dynamic diamond anvil cell (RHdDAC) for fast compression x-ray diffraction experiments at high temperatures.
    Méndez ASJ; Marquardt H; Husband RJ; Schwark I; Mainberger J; Glazyrin K; Kurnosov A; Otzen C; Satta N; Bednarcik J; Liermann HP
    Rev Sci Instrum; 2020 Jul; 91(7):073906. PubMed ID: 32752811
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Characterization of piezoelectric wafer active sensor for acoustic emission sensing.
    Bhuiyan Y; Lin B; Giurgiutiu V
    Ultrasonics; 2019 Feb; 92():35-49. PubMed ID: 30218898
    [TBL] [Abstract][Full Text] [Related]  

  • 14. DIASCoPE: Directly integrated acoustic system combined with pressure experiments-A new method for fast acoustic velocity measurements at high pressure.
    Whitaker ML; Baldwin KJ; Huebsch WR
    Rev Sci Instrum; 2017 Mar; 88(3):034901. PubMed ID: 28372428
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The Extreme Conditions Beamline P02.2 and the Extreme Conditions Science Infrastructure at PETRA III.
    Liermann HP; Konôpková Z; Morgenroth W; Glazyrin K; Bednarčik J; McBride EE; Petitgirard S; Delitz JT; Wendt M; Bican Y; Ehnes A; Schwark I; Rothkirch A; Tischer M; Heuer J; Schulte-Schrepping H; Kracht T; Franz H
    J Synchrotron Radiat; 2015 Jul; 22(4):908-24. PubMed ID: 26134794
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High-temperature experiments using a resistively heated high-pressure membrane diamond anvil cell.
    Jenei Z; Cynn H; Visbeck K; Evans WJ
    Rev Sci Instrum; 2013 Sep; 84(9):095114. PubMed ID: 24089873
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optical calibration for both out-of-plane and in-plane displacement sensitivity of acoustic emission sensors.
    Theobald PD
    Ultrasonics; 2009 Dec; 49(8):623-7. PubMed ID: 19409592
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Simultaneous imaging and diffraction in the dynamic diamond anvil cell.
    Husband RJ; Hagemann J; O'Bannon EF; Liermann HP; Glazyrin K; Sneed DT; Lipp MJ; Schropp A; Evans WJ; Jenei Z
    Rev Sci Instrum; 2022 May; 93(5):053903. PubMed ID: 35649806
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An endstation for resonant inelastic X-ray scattering studies of solid and liquid samples.
    Yin Z; Peters HB; Hahn U; Gonschior J; Mierwaldt D; Rajkovic I; Viefhaus J; Jooss C; Techert S
    J Synchrotron Radiat; 2017 Jan; 24(Pt 1):302-306. PubMed ID: 28009571
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A new highly automated sputter equipment for in situ investigation of deposition processes with synchrotron radiation.
    Döhrmann R; Botta S; Buffet A; Santoro G; Schlage K; Schwartzkopf M; Bommel S; Risch JF; Mannweiler R; Brunner S; Metwalli E; Müller-Buschbaum P; Roth SV
    Rev Sci Instrum; 2013 Apr; 84(4):043901. PubMed ID: 23635203
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.