These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 36868544)

  • 1. Mechanics of lumenless pacing lead strength during extraction procedures based on laboratory bench testing.
    Vatterott PJ; Mondésert B; Marshall M; Lulic T; Wilkoff BL
    Heart Rhythm; 2023 Jun; 20(6):902-909. PubMed ID: 36868544
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transvenous lead extraction of lumenless 3830 pacing lead in conduction system pacing: a single-center experience.
    Migliore F; Pittorru R; De Lazzari M; Tarzia V; Pastore G; Marcantoni L; Catanzariti D; Gerosa G; Zanon F
    J Interv Card Electrophysiol; 2024 Jan; 67(1):175-182. PubMed ID: 37365481
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Rationale for and use of the lumenless 3830 pacing lead.
    Richardson TD; Himes A; Marshall M; Crossley GH
    J Cardiovasc Electrophysiol; 2023 Mar; 34(3):769-774. PubMed ID: 36682066
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Strategies to maximize lead tensile strength during extraction in three families of pacing leads.
    Vatterott P; Finley J; Savela J; De Kock A; Lewis R
    Heart Rhythm; 2024 Jun; 21(6):929-938. PubMed ID: 38215809
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical use conditions of lead deployment and simulated lead fracture rate in left bundle branch area pacing.
    Zou J; Chen K; Liu X; Xu Y; Jiang L; Dai Y; Lin J; Hou X; Qiu Y; Himes A; Lucas R; Demmer W; Mara N; Zhou X; Lu H
    J Cardiovasc Electrophysiol; 2023 Mar; 34(3):718-725. PubMed ID: 36738153
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Alternative delivery of a 4Fr lumenless pacing lead in children.
    Lapage MJ; Rhee EK
    Pacing Clin Electrophysiol; 2008 May; 31(5):543-7. PubMed ID: 18439166
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Implantation of lumenless pacing leads at the inter-atrial septum and right ventricular outflow tract with deflectable catheter-sheath.
    Bai R; Kam R; Ching CK; Hsu LF; Teo WS
    J Huazhong Univ Sci Technolog Med Sci; 2008 Dec; 28(6):639-44. PubMed ID: 19107356
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Repositioning a dislodged new lumenless pacing lead: a simple tool and technique.
    Karpawich PP; Webster P; Goodman E; Forbes T
    Pacing Clin Electrophysiol; 2008 Mar; 31(3):354-7. PubMed ID: 18307633
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Strategies to increase the INGEVITY lead strength during lead extraction procedures based on laboratory bench testing.
    Vatterott P; De Kock A; Hammill EF; Lewis R
    Pacing Clin Electrophysiol; 2021 Aug; 44(8):1320-1330. PubMed ID: 34184293
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Initial experience with stylet-driven versus lumenless lead delivery systems for left bundle branch area pacing.
    Braunstein ED; Kagan RD; Olshan DS; Gabriels JK; Thomas G; Ip JE; Markowitz SM; Lerman BB; Liu CF; Cheung JW
    J Cardiovasc Electrophysiol; 2023 Mar; 34(3):710-717. PubMed ID: 36571159
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Noncatheter-based delivery of a single-chamber lumenless pacing lead in small children.
    Kenny D; Walsh KP
    Pacing Clin Electrophysiol; 2007 Jul; 30(7):834-8. PubMed ID: 17584263
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Extraction of SelectSecure leads compared to conventional pacing leads in patients with congenital heart disease and congenital atrioventricular block.
    Shepherd E; Stuart G; Martin R; Walsh MA
    Heart Rhythm; 2015 Jun; 12(6):1227-32. PubMed ID: 25748672
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pitfalls and tips for lumenless lead extraction inserted deep within the ventricular septum.
    Tomura N; Shiraishi H; Makino M; Munakata J; Shimoo S; Iwakoshi H; Nishimura T; Ohkura T; Senoo K; Matoba S
    Clin Case Rep; 2024 May; 12(5):e8718. PubMed ID: 38681029
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Epicardial implantation of a lumenless active fixation lead in a neonate.
    Zhang J; Dong Z; Ma S; Abdukadir A; Tang B; Xu Y
    Pacing Clin Electrophysiol; 2023 Nov; 46(11):1366-1369. PubMed ID: 36896741
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ten-Year Clinical Experience with the Lumenless, Catheter-Delivered, 4.1-Fr Diameter Pacing Lead in Patients with and without Congenital Heart.
    Bansal N; Samuel S; Zelin K; Karpawich PP
    Pacing Clin Electrophysiol; 2017 Jan; 40(1):17-25. PubMed ID: 28004408
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Initial experience of pacing with a lumenless lead system in patients with congenital heart disease.
    Chakrabarti S; Morgan GJ; Kenny D; Walsh KP; Oslizlok P; Martin RP; Turner MS; Stuart AG
    Pacing Clin Electrophysiol; 2009 Nov; 32(11):1428-33. PubMed ID: 19769583
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transatrial lead implantation using the 4-Fr lumenless pacing lead and delivery system in young adults with congenital heart disease.
    Fishberger SB; Rollinson NR; Warsy I; Whang B; Kim RW
    Pacing Clin Electrophysiol; 2009 Dec; 32(12):e40-2. PubMed ID: 19744269
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Complications of permanent cardiac pacing in patients with persistent left superior vena cava.
    Polewczyk A; Kutarski A; Czekajska-Chehab E; Adamczyk P; Boczar K; Polewczyk M; Janion M
    Cardiol J; 2014; 21(2):128-37. PubMed ID: 24526508
    [TBL] [Abstract][Full Text] [Related]  

  • 19. How to Perform Permanent His Bundle Pacing: Tips and Tricks.
    Vijayaraman P; Dandamudi G
    Pacing Clin Electrophysiol; 2016 Dec; 39(12):1298-1304. PubMed ID: 27273200
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Right Ventricular Septal Pacing Using a Thin Lumenless Pacing Lead and Delivery System with a Deflectable Catheter.
    Suzuki T; Fujino T; Shinohara M; Koike H; Kinoshita T; Yuzawa H; Ikeda T
    Int Heart J; 2018 Nov; 59(6):1253-1260. PubMed ID: 30393261
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.