169 related articles for article (PubMed ID: 36882991)
1. Screw-retained internal connection zirconia CAD-CAM abutments in single implant reconstructions: Results of a 1-year prospective case series study.
Del Castillo R; Gutiérrez-Garrido L; Padial-Molina M; Galindo-Moreno P
J Prosthodont; 2023 Oct; 32(8):679-688. PubMed ID: 36882991
[TBL] [Abstract][Full Text] [Related]
2. Monolithic zirconia single tooth implant-supported restorations with CAD/CAM titanium abutments in the posterior region: A 1-year prospective case series study.
Donker VJJ; Raghoebar GM; Jensen-Louwerse C; Vissink A; Meijer HJA
Clin Implant Dent Relat Res; 2022 Feb; 24(1):125-132. PubMed ID: 35075756
[TBL] [Abstract][Full Text] [Related]
3. Peri-implant and esthetic outcomes of cemented and screw-retained crowns using zirconia abutments in single implant-supported restorations-A systematic review and meta-analysis.
Dini C; Borges GA; Costa RC; Magno MB; Maia LC; Barão VAR
Clin Oral Implants Res; 2021 Oct; 32(10):1143-1158. PubMed ID: 34352144
[TBL] [Abstract][Full Text] [Related]
4. Randomized Controlled Clinical Trial of All-Ceramic Single-Tooth Implant Reconstructions Using Modified Zirconia Abutments: Results at 5 Years After Loading.
Laass A; Sailer I; Hüsler J; Hämmerle CH; Thoma DS
Int J Periodontics Restorative Dent; 2019; 39(1):17-27. PubMed ID: 30543723
[TBL] [Abstract][Full Text] [Related]
5. Influence of margin location and luting material on the amount of undetected cement excess on CAD/CAM implant abutments and cement-retained zirconia crowns: an in-vitro study.
Gehrke P; Bleuel K; Fischer C; Sader R
BMC Oral Health; 2019 Jun; 19(1):111. PubMed ID: 31200680
[TBL] [Abstract][Full Text] [Related]
6. Clinical Performance of One-Piece, Screw-Retained Implant Crowns Based on Hand-Veneered CAD/CAM Zirconia Abutments After a Mean Follow-up Period of 2.3 Years.
Schnider N; Forrer FA; Brägger U; Hicklin SP
Int J Oral Maxillofac Implants; 2018; 33(1):188-196. PubMed ID: 29340353
[TBL] [Abstract][Full Text] [Related]
7. Clinical performance of implant crowns with customized zirconia abutments: A prospective cohort study with a 4.5- to 8.8-year follow-up.
Fonseca M; Molinero-Mourelle P; Forrer FA; Schnider N; Hicklin SP; Schimmel M; Brägger U
Clin Oral Implants Res; 2021 Jul; 32(7):853-862. PubMed ID: 33949004
[TBL] [Abstract][Full Text] [Related]
8. Stock Versus CAD/CAM Customized Zirconia Implant Abutments - Clinical and Patient-Based Outcomes in a Randomized Controlled Clinical Trial.
Schepke U; Meijer HJ; Kerdijk W; Raghoebar GM; Cune M
Clin Implant Dent Relat Res; 2017 Feb; 19(1):74-84. PubMed ID: 27476829
[TBL] [Abstract][Full Text] [Related]
9. [Full-zirconia single-tooth molar implant-supported restorations with angulated screw channel abutments: evaluation of short-term outcomes].
Lin HX; Huang J; Sun YX; Xia JX
Shanghai Kou Qiang Yi Xue; 2021 Aug; 30(4):384-388. PubMed ID: 34693431
[TBL] [Abstract][Full Text] [Related]
10. Zirconia abutments for single-tooth implant restorations: a retrospective and clinical follow-up study.
Ekfeldt A; Fürst B; Carlsson GE
Clin Oral Implants Res; 2011 Nov; 22(11):1308-14. PubMed ID: 21382085
[TBL] [Abstract][Full Text] [Related]
11. Full-zirconia single-tooth molar implant-supported restorations with angulated screw channel abutments: A 1-year prospective case series study.
Pol CWP; Raghoebar GM; Maragkou Z; Cune MS; Meijer HJA
Clin Implant Dent Relat Res; 2020 Feb; 22(1):138-144. PubMed ID: 31793193
[TBL] [Abstract][Full Text] [Related]
12. A Novel Full-Digital Protocol (SCAN-PLAN-MAKE-DONE
Mangano F; Margiani B; Admakin O
Int J Environ Res Public Health; 2019 Jan; 16(3):. PubMed ID: 30678357
[TBL] [Abstract][Full Text] [Related]
13. Comparison of Cemented vs Screw-Retained, Customized Computer-Aided Design/Computer-Assisted Manufacture Zirconia Abutments for Esthetically Located Single-Tooth Implants: A 10-Year Randomized Prospective Study.
Amorfini L; Storelli S; Mosca D; Scanferla M; Romeo E
Int J Prosthodont; 2018; 31(4):359–366. PubMed ID: 29624628
[TBL] [Abstract][Full Text] [Related]
14. Randomized clinical trial of zirconia and polyetheretherketone implant abutments for single-tooth implant restorations: A 5-year evaluation.
Ayyadanveettil P; Thavakkara V; Latha N; Pavanan M; Saraswathy A; Kuruniyan MS
J Prosthet Dent; 2022 Dec; 128(6):1275-1281. PubMed ID: 33933267
[TBL] [Abstract][Full Text] [Related]
15. One-piece internal zirconia abutments for single-tooth restorations on narrow and regular diameter implants: A 5-year prospective follow-up study.
Nilsson A; Johansson LÅ; Lindh C; Ekfeldt A
Clin Implant Dent Relat Res; 2017 Oct; 19(5):916-925. PubMed ID: 28791801
[TBL] [Abstract][Full Text] [Related]
16. Prospective assessment of CAD/CAM zirconia abutment and lithium disilicate crown restorations: 2.4 year results.
Cooper LF; Stanford C; Feine J; McGuire M
J Prosthet Dent; 2016 Jul; 116(1):33-9. PubMed ID: 26831919
[TBL] [Abstract][Full Text] [Related]
17. Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study.
Glauser R; Sailer I; Wohlwend A; Studer S; Schibli M; Schärer P
Int J Prosthodont; 2004; 17(3):285-90. PubMed ID: 15237873
[TBL] [Abstract][Full Text] [Related]
18. Optimizing the esthetic outcome by using screw-retained implant abutment crowns: A 3-year clinical follow-up.
Cicero E; El Rafie K; De Souza A; Kawabe Y; Kang K; Att W
J Prosthet Dent; 2021 Nov; 126(5):608-615. PubMed ID: 33160619
[TBL] [Abstract][Full Text] [Related]
19. Esthetic and Clinical Performance of Implant-Supported All-Ceramic Crowns Made with Prefabricated or CAD/CAM Zirconia Abutments: A Randomized, Multicenter Clinical Trial.
Wittneben JG; Gavric J; Belser UC; Bornstein MM; Joda T; Chappuis V; Sailer I; Brägger U
J Dent Res; 2017 Feb; 96(2):163-170. PubMed ID: 27927884
[TBL] [Abstract][Full Text] [Related]
20. The clinical use of computer aided designed/computer aided manufactured titanium nitride coated implant abutments: Surgical and prosthetic considerations-A case series.
Del Castillo R; Ata-Ali J
J Esthet Restor Dent; 2023 Oct; 35(7):1008-1021. PubMed ID: 36932837
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]