141 related articles for article (PubMed ID: 36892722)
1. Image-guided navigation system for minimally invasive total hip arthroplasty (MITHA) using an improved position-sensing marker.
Xie X; Zhu M; He B; Xu J
Int J Comput Assist Radiol Surg; 2023 Dec; 18(12):2155-2166. PubMed ID: 36892722
[TBL] [Abstract][Full Text] [Related]
2. Spatial Position Measurement System for Surgical Navigation Using 3-D Image Marker-Based Tracking Tools With Compact Volume.
Fan Z; Chen G; Wang J; Liao H
IEEE Trans Biomed Eng; 2018 Feb; 65(2):378-389. PubMed ID: 29346106
[TBL] [Abstract][Full Text] [Related]
3. Automatic correction of registration errors in surgical navigation systems.
Wittmann W; Wenger T; Zaminer B; Lueth TC
IEEE Trans Biomed Eng; 2011 Oct; 58(10):2922-30. PubMed ID: 21803677
[TBL] [Abstract][Full Text] [Related]
4. Navigation system for minimally invasive esophagectomy: experimental study in a porcine model.
Nickel F; Kenngott HG; Neuhaus J; Sommer CM; Gehrig T; Kolb A; Gondan M; Radeleff BA; Schaible A; Meinzer HP; Gutt CN; Müller-Stich BP
Surg Endosc; 2013 Oct; 27(10):3663-70. PubMed ID: 23549772
[TBL] [Abstract][Full Text] [Related]
5. Fusion of multimodality image and point cloud for spatial surface registration for knee arthroplasty.
Liu Y; Yao D; Zhai Z; Wang H; Chen J; Wu C; Qiao H; Li H; Shi Y
Int J Med Robot; 2022 Oct; 18(5):e2426. PubMed ID: 35635380
[TBL] [Abstract][Full Text] [Related]
6. In-vitro assessment of a registration protocol for image guided implant dentistry.
Birkfellner W; Solar P; Gahleitner A; Huber K; Kainberger F; Kettenbach J; Homolka P; Diemling M; Watzek G; Bergmann H
Clin Oral Implants Res; 2001 Feb; 12(1):69-78. PubMed ID: 11168273
[TBL] [Abstract][Full Text] [Related]
7. A markerless automatic deformable registration framework for augmented reality navigation of laparoscopy partial nephrectomy.
Zhang X; Wang J; Wang T; Ji X; Shen Y; Sun Z; Zhang X
Int J Comput Assist Radiol Surg; 2019 Aug; 14(8):1285-1294. PubMed ID: 31016562
[TBL] [Abstract][Full Text] [Related]
8. Image-Less THA Cup Navigation in Clinical Routine Setup: Individual Adjustments, Accuracy, Precision, and Robustness.
Zurmühle CA; Zickmantel B; Christen M; Christen B; Zheng G; Schwab JM; Tannast M; Steppacher SD
Medicina (Kaunas); 2022 Jun; 58(6):. PubMed ID: 35744095
[TBL] [Abstract][Full Text] [Related]
9. Fiducial-based registration with a touchable region model.
Kim S; Kazanzides P
Int J Comput Assist Radiol Surg; 2017 Feb; 12(2):277-289. PubMed ID: 27581335
[TBL] [Abstract][Full Text] [Related]
10. Intra-operative fiducial-based CT/fluoroscope image registration framework for image-guided robot-assisted joint fracture surgery.
Dagnino G; Georgilas I; Morad S; Gibbons P; Tarassoli P; Atkins R; Dogramadzi S
Int J Comput Assist Radiol Surg; 2017 Aug; 12(8):1383-1397. PubMed ID: 28474269
[TBL] [Abstract][Full Text] [Related]
11. [Accuracy measurements of acetabular cup positioning using CT less navigation].
Blendea S; Troccaz J; Merloz P
Rev Chir Orthop Reparatrice Appar Mot; 2007 Apr; 93(2):157-64. PubMed ID: 17401289
[TBL] [Abstract][Full Text] [Related]
12. Determining the position of a patient reference from C-Arm views for image guided navigation.
Wei W; Schön N; Dannenmann T; Petzold R
Int J Comput Assist Radiol Surg; 2011 Mar; 6(2):217-27. PubMed ID: 20640603
[TBL] [Abstract][Full Text] [Related]
13. An incremental registration method for endoscopic sinus and skull base surgery navigation: From phantom study to clinical trials.
Li W; Fan J; Li S; Zheng Z; Tian Z; Ai D; Song H; Chen X; Yang J
Med Phys; 2023 Jan; 50(1):226-239. PubMed ID: 35997999
[TBL] [Abstract][Full Text] [Related]
14. Application accuracy in frameless image-guided neurosurgery: a comparison study of three patient-to-image registration methods.
Woerdeman PA; Willems PW; Noordmans HJ; Tulleken CA; van der Sprenkel JW
J Neurosurg; 2007 Jun; 106(6):1012-6. PubMed ID: 17564173
[TBL] [Abstract][Full Text] [Related]
15. An oral and maxillofacial navigation system for implant placement with automatic identification of fiducial points.
Qin C; Cao Z; Fan S; Wu Y; Sun Y; Politis C; Wang C; Chen X
Int J Comput Assist Radiol Surg; 2019 Feb; 14(2):281-289. PubMed ID: 30317436
[TBL] [Abstract][Full Text] [Related]
16. Ultrasound-based navigation and 3D CT compared in acetabular cup position.
Hasart O; Poepplau BM; Asbach P; Perka C; Wassilew GI
Orthopedics; 2009 Oct; 32(10 Suppl):6-10. PubMed ID: 19835299
[TBL] [Abstract][Full Text] [Related]
17. Image guided navigation by intraoperative CT scan for cochlear implantation.
Stelter K; Ledderose G; Hempel JM; Morhard DF; Flatz W; Krause E; Mueller J
Comput Aided Surg; 2012; 17(3):153-60. PubMed ID: 22452534
[TBL] [Abstract][Full Text] [Related]
18. Anterior pelvic plane registration accuracy and cup position measurement using ultrasound- and pointer-based navigation in primary total hip arthroplasty.
Kiefer H; Löchel J; Sambo K; Leder B; Wassilew GI
Technol Health Care; 2020; 28(3):315-323. PubMed ID: 31658073
[TBL] [Abstract][Full Text] [Related]
19. Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: a cadaver study.
Lin F; Lim D; Wixson RL; Milos S; Hendrix RW; Makhsous M
Clin Biomech (Bristol, Avon); 2008 Oct; 23(8):1004-11. PubMed ID: 18541352
[TBL] [Abstract][Full Text] [Related]
20. Image-guided minimally invasive endopancreatic surgery using a computer-assisted navigation system.
Müller PC; Haslebacher C; Steinemann DC; Müller-Stich BP; Hackert T; Peterhans M; Eigl B
Surg Endosc; 2021 Apr; 35(4):1610-1617. PubMed ID: 32253555
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]