150 related articles for article (PubMed ID: 36893475)
1. Validation of HDR brachytherapy doses in the treatment of keloid scars using the egs_brachy Monte Carlo application.
Saikkonen A; Ojala J; Sipilä P; Boman E; Keyriläinen J
Phys Med Biol; 2023 Apr; 68(8):. PubMed ID: 36893475
[No Abstract] [Full Text] [Related]
2. Dosimetry of a sonolucent material for an ultrasound-compatible gynecologic high-dose-rate brachytherapy cylinder using Monte Carlo simulation and radiochromic film.
Van Elburg DJ; Roumeliotis M; Morrison H; Rodgers JR; Fenster A; Meyer T
Brachytherapy; 2021; 20(1):265-271. PubMed ID: 33039331
[TBL] [Abstract][Full Text] [Related]
3. A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate
Ma Y; Vijande J; Ballester F; Tedgren ÅC; Granero D; Haworth A; Mourtada F; Fonseca GP; Zourari K; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith R; Chamberland MJP; Thomson RM; Verhaegen F; Beaulieu L
Med Phys; 2017 Nov; 44(11):5961-5976. PubMed ID: 28722180
[TBL] [Abstract][Full Text] [Related]
4. Dosimetric assessment of an air-filled balloon applicator in HDR vaginal cuff brachytherapy using the Monte Carlo method.
Jiang H; Badkul R; Pokhrel D
J Appl Clin Med Phys; 2018 May; 19(3):101-107. PubMed ID: 29493101
[TBL] [Abstract][Full Text] [Related]
5. A generic high-dose rate (192)Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism.
Ballester F; Carlsson Tedgren Å; Granero D; Haworth A; Mourtada F; Fonseca GP; Zourari K; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith RL; Thomson RM; Verhaegen F; Vijande J; Ma Y; Beaulieu L
Med Phys; 2015 Jun; 42(6):3048-61. PubMed ID: 26127057
[TBL] [Abstract][Full Text] [Related]
6. Update of the CLRP Monte Carlo TG-43 parameter database for high-energy brachytherapy sources.
Safigholi H; Chamberland MJP; Taylor REP; Martinov MP; Rogers DWO; Thomson RM
Med Phys; 2023 Mar; 50(3):1928-1941. PubMed ID: 36542404
[TBL] [Abstract][Full Text] [Related]
7. egs_brachy: a versatile and fast Monte Carlo code for brachytherapy.
Chamberland MJ; Taylor RE; Rogers DW; Thomson RM
Phys Med Biol; 2016 Dec; 61(23):8214-8231. PubMed ID: 27804922
[TBL] [Abstract][Full Text] [Related]
8. Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions.
Candela-Juan C; Niatsetski Y; van der Laarse R; Granero D; Ballester F; Perez-Calatayud J; Vijande J
Med Phys; 2016 Apr; 43(4):1639. PubMed ID: 27036563
[TBL] [Abstract][Full Text] [Related]
9. Validation of a Monte Carlo model for multi leaf collimator based electron delivery.
Kaluarachchi MM; Saleh ZH; Schwer ML; Klein EE
Med Phys; 2020 Aug; 47(8):3586-3599. PubMed ID: 32324289
[TBL] [Abstract][Full Text] [Related]
10. A comparison of HDR near source dosimetry using a treatment planning system, Monte Carlo simulation, and radiochromic film.
Amoush A; Luckstead M; Lamba M; Elson H; Kassing W
Med Dosim; 2013; 38(2):160-4. PubMed ID: 23246195
[TBL] [Abstract][Full Text] [Related]
11. Dosimetric characterization of round HDR 192Ir accuboost applicators for breast brachytherapy.
Rivard MJ; Melhus CS; Wazer DE; Bricault RJ
Med Phys; 2009 Nov; 36(11):5027-32. PubMed ID: 19994513
[TBL] [Abstract][Full Text] [Related]
12. Measured, calculated, and egs_brachy I-125 dose distributions in a gold plaque for retinoblastoma treatment.
Trauernicht CJ; van Eeden D; du Plessis FCP
Med Phys; 2022 Sep; 49(9):6183-6194. PubMed ID: 35792659
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of dosimetric effects of metallic artifact reduction and tissue assignment on Monte Carlo dose calculations for
Assam I; Vijande J; Ballester F; Pérez-Calatayud J; Poppe B; Siebert FA
Med Phys; 2022 Sep; 49(9):6195-6208. PubMed ID: 35925023
[TBL] [Abstract][Full Text] [Related]
14. Monte Carlo Study on Dose Distributions Around
Mishra S; Mishra B; Selvam TP; Deshpande S; Pathan MS; Kumar R
J Med Phys; 2022; 47(3):270-278. PubMed ID: 36684701
[TBL] [Abstract][Full Text] [Related]
15. On the experimental validation of model-based dose calculation algorithms for
Pappas EP; Zoros E; Moutsatsos A; Peppa V; Zourari K; Karaiskos P; Papagiannis P
Phys Med Biol; 2017 May; 62(10):4160-4182. PubMed ID: 28353447
[TBL] [Abstract][Full Text] [Related]
16. Development of a phantom to validate high-dose-rate brachytherapy treatment planning systems with heterogeneous algorithms.
Moura ES; Micka JA; Hammer CG; Culberson WS; DeWerd LA; Rostelato ME; Zeituni CA
Med Phys; 2015 Apr; 42(4):1566-74. PubMed ID: 25832047
[TBL] [Abstract][Full Text] [Related]
17. Dose comparison between TG-43-based calculations and radiochromic film measurements of the Freiburg flap applicator used for high-dose-rate brachytherapy treatments of skin lesions.
Aldelaijan S; Bekerat H; Buzurovic I; Devlin P; DeBlois F; Seuntjens J; Devic S
Brachytherapy; 2017; 16(5):1065-1072. PubMed ID: 28735877
[TBL] [Abstract][Full Text] [Related]
18. Comparison of
Safigholi H; Meigooni AS; Song WY
Med Phys; 2017 Sep; 44(9):4426-4436. PubMed ID: 28494095
[TBL] [Abstract][Full Text] [Related]
19. Update of the CLRP TG-43 parameter database for low-energy brachytherapy sources.
Safigholi H; Chamberland MJP; Taylor REP; Allen CH; Martinov MP; Rogers DWO; Thomson RM
Med Phys; 2020 Sep; 47(9):4656-4669. PubMed ID: 32436344
[TBL] [Abstract][Full Text] [Related]
20. Determination of transit dose profile for a (192)Ir HDR source.
Fonseca GP; Rubo RA; Minamisawa RA; dos Santos GR; Antunes PC; Yoriyaz H
Med Phys; 2013 May; 40(5):051717. PubMed ID: 23635265
[TBL] [Abstract][Full Text] [Related]