These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
165 related articles for article (PubMed ID: 36900057)
1. Whale Optimization Algorithm with a Hybrid Relation Vector Machine: A Highly Robust Respiratory Rate Prediction Model Using Photoplethysmography Signals. Dong X; Wang Z; Cao L; Chen Z; Liang Y Diagnostics (Basel); 2023 Feb; 13(5):. PubMed ID: 36900057 [TBL] [Abstract][Full Text] [Related]
2. Ensemble Empirical Mode Decomposition With Principal Component Analysis: A Novel Approach for Extracting Respiratory Rate and Heart Rate From Photoplethysmographic Signal. Motin MA; Karmakar CK; Palaniswami M IEEE J Biomed Health Inform; 2018 May; 22(3):766-774. PubMed ID: 28287994 [TBL] [Abstract][Full Text] [Related]
3. An EEMD-PCA approach to extract heart rate, respiratory rate and respiratory activity from PPG signal. Motin MA; Karmakar CK; Palaniswami M Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():3817-3820. PubMed ID: 28269118 [TBL] [Abstract][Full Text] [Related]
4. PPG-Based Respiratory Rate Monitoring Using Hybrid Vote-Aggregate Fusion Technique. Haddad S; Boukhayma A; Caizzone A Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():1605-1608. PubMed ID: 34891592 [TBL] [Abstract][Full Text] [Related]
5. Monitoring of heart and respiratory rates in newborn infants using a new photoplethysmographic technique. Johansson A; Oberg PA; Sedin G J Clin Monit Comput; 1999 Dec; 15(7-8):461-7. PubMed ID: 12578044 [TBL] [Abstract][Full Text] [Related]
6. Reference signal less Fourier analysis based motion artifact removal algorithm for wearable photoplethysmography devices to estimate heart rate during physical exercises. Pankaj ; Kumar A; Komaragiri R; Kumar M Comput Biol Med; 2022 Feb; 141():105081. PubMed ID: 34952340 [TBL] [Abstract][Full Text] [Related]
7. In obstructive sleep apnea patients, automatic determination of respiratory arrests by photoplethysmography signal and heart rate variability. Bozkurt MR; Uçar MK; Bozkurt F; Bilgin C Australas Phys Eng Sci Med; 2019 Dec; 42(4):959-979. PubMed ID: 31515685 [TBL] [Abstract][Full Text] [Related]
8. Derivation of respiration rate from ambulatory ECG and PPG using Ensemble Empirical Mode Decomposition: Comparison and fusion. Orphanidou C Comput Biol Med; 2017 Feb; 81():45-54. PubMed ID: 28012294 [TBL] [Abstract][Full Text] [Related]
9. Bayesian fusion of algorithms for the robust estimation of respiratory rate from the photoplethysmogram. Zhu T; Pimentel MA; Clifford GD; Clifton DA Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():6138-41. PubMed ID: 26737693 [TBL] [Abstract][Full Text] [Related]
10. A Robust Dynamic Heart-Rate Detection Algorithm Framework During Intense Physical Activities Using Photoplethysmographic Signals. Song J; Li D; Ma X; Teng G; Wei J Sensors (Basel); 2017 Oct; 17(11):. PubMed ID: 29068403 [TBL] [Abstract][Full Text] [Related]
11. Lightweight End-to-End Deep Learning Solution for Estimating the Respiration Rate from Photoplethysmogram Signal. Chowdhury MH; Shuzan MNI; Chowdhury MEH; Reaz MBI; Mahmud S; Al Emadi N; Ayari MA; Ali SHM; Bakar AAA; Rahman SM; Khandakar A Bioengineering (Basel); 2022 Oct; 9(10):. PubMed ID: 36290527 [TBL] [Abstract][Full Text] [Related]
12. A pulse transit time based fusion method for the noninvasive and continuous monitoring of respiratory rate. Xiao-Rong Ding ; Yuan-Ting Zhang ; Hon Ki Tsang ; Karlen W Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():4240-4243. PubMed ID: 28269218 [TBL] [Abstract][Full Text] [Related]
13. Monitoring of respiratory rate in postoperative care using a new photoplethysmographic technique. Nilsson L; Johansson A; Kalman S J Clin Monit Comput; 2000; 16(4):309-15. PubMed ID: 12578078 [TBL] [Abstract][Full Text] [Related]
14. A Sliding Scale Signal Quality Metric of Photoplethysmography Applicable to Measuring Heart Rate across Clinical Contexts with Chest Mounting as a Case Study. McLean MK; Weaver RG; Lane A; Smith MT; Parker H; Stone B; McAninch J; Matolak DW; Burkart S; Chandrashekhar MVS; Armstrong B Sensors (Basel); 2023 Mar; 23(7):. PubMed ID: 37050488 [TBL] [Abstract][Full Text] [Related]
15. Respiratory rate monitoring from the photoplethysmogram via sparse signal reconstruction. Zhang X; Ding Q Physiol Meas; 2016 Jul; 37(7):1105-19. PubMed ID: 27319303 [TBL] [Abstract][Full Text] [Related]
16. SVR-EEMD: An Improved EEMD Method Based on Support Vector Regression Extension in PPG Signal Denoising. Liu G; Hu X; Wang E; Zhou G; Cai J; Zhang S Comput Math Methods Med; 2019; 2019():5363712. PubMed ID: 31915461 [TBL] [Abstract][Full Text] [Related]
17. Estimation of Heart Rate and Respiratory Rate from PPG Signal Using Complementary Ensemble Empirical Mode Decomposition with both Independent Component Analysis and Non-Negative Matrix Factorization. Lei R; Ling BW; Feng P; Chen J Sensors (Basel); 2020 Jun; 20(11):. PubMed ID: 32517226 [TBL] [Abstract][Full Text] [Related]
19. PPG2RespNet: a deep learning model for respirational signal synthesis and monitoring from photoplethysmography (PPG) signal. Shuzan MNI; Chowdhury MH; Alam SB; Reaz MBI; Khan MS; Murugappan M; Chowdhury MEH Phys Eng Sci Med; 2024 Dec; 47(4):1705-1722. PubMed ID: 39287773 [TBL] [Abstract][Full Text] [Related]
20. Machine Learning-Based Respiration Rate and Blood Oxygen Saturation Estimation Using Photoplethysmogram Signals. Shuzan MNI; Chowdhury MH; Chowdhury MEH; Murugappan M; Hoque Bhuiyan E; Arslane Ayari M; Khandakar A Bioengineering (Basel); 2023 Jan; 10(2):. PubMed ID: 36829661 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]