234 related articles for article (PubMed ID: 36905954)
1. Immune cell response to orthopedic and craniofacial biomaterials depends on biomaterial composition.
Avery D; Morandini L; Celt N; Bergey L; Simmons J; Martin RK; Donahue HJ; Olivares-Navarrete R
Acta Biomater; 2023 Apr; 161():285-297. PubMed ID: 36905954
[TBL] [Abstract][Full Text] [Related]
2. Implant materials generate different peri-implant inflammatory factors: poly-ether-ether-ketone promotes fibrosis and microtextured titanium promotes osteogenic factors.
Olivares-Navarrete R; Hyzy SL; Slosar PJ; Schneider JM; Schwartz Z; Boyan BD
Spine (Phila Pa 1976); 2015 Mar; 40(6):399-404. PubMed ID: 25584952
[TBL] [Abstract][Full Text] [Related]
3. Osteoblasts exhibit a more differentiated phenotype and increased bone morphogenetic protein production on titanium alloy substrates than on poly-ether-ether-ketone.
Olivares-Navarrete R; Gittens RA; Schneider JM; Hyzy SL; Haithcock DA; Ullrich PF; Schwartz Z; Boyan BD
Spine J; 2012 Mar; 12(3):265-72. PubMed ID: 22424980
[TBL] [Abstract][Full Text] [Related]
4. Carbon/PEEK composite materials as an alternative for stainless steel/titanium hip prosthesis: a finite element study.
Rezaei F; Hassani K; Solhjoei N; Karimi A
Australas Phys Eng Sci Med; 2015 Dec; 38(4):569-80. PubMed ID: 26462678
[TBL] [Abstract][Full Text] [Related]
5. In vitro corrosion behavior of bioceramic, metallic, and bioceramic-metallic coated stainless steel dental implants.
Fathi MH; Salehi M; Saatchi A; Mortazavi V; Moosavi SB
Dent Mater; 2003 May; 19(3):188-98. PubMed ID: 12628430
[TBL] [Abstract][Full Text] [Related]
6. Influence of polyetheretherketone coatings on the Ti-13Nb-13Zr titanium alloy's bio-tribological properties and corrosion resistance.
Sak A; Moskalewicz T; Zimowski S; Cieniek Ł; Dubiel B; Radziszewska A; Kot M; Łukaszczyk A
Mater Sci Eng C Mater Biol Appl; 2016 Jun; 63():52-61. PubMed ID: 27040195
[TBL] [Abstract][Full Text] [Related]
7. A comparative study of the in vitro corrosion behavior and cytotoxicity of a superferritic stainless steel, a Ti-13Nb-13Zr alloy, and an austenitic stainless steel in Hank's solution.
Assis SL; Rogero SO; Antunes RA; Padilha AF; Costa I
J Biomed Mater Res B Appl Biomater; 2005 Apr; 73(1):109-16. PubMed ID: 15660438
[TBL] [Abstract][Full Text] [Related]
8. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
[TBL] [Abstract][Full Text] [Related]
9. Decreased bacteria activity on Si₃N₄ surfaces compared with PEEK or titanium.
Gorth DJ; Puckett S; Ercan B; Webster TJ; Rahaman M; Bal BS
Int J Nanomedicine; 2012; 7():4829-40. PubMed ID: 22973102
[TBL] [Abstract][Full Text] [Related]
10. Comparative in vitro biocompatibility of nickel-titanium, pure nickel, pure titanium, and stainless steel: genotoxicity and atomic absorption evaluation.
Assad M; Lemieux N; Rivard CH; Yahia LH
Biomed Mater Eng; 1999; 9(1):1-12. PubMed ID: 10436848
[TBL] [Abstract][Full Text] [Related]
11. Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?
Serhan H; Slivka M; Albert T; Kwak SD
Spine J; 2004; 4(4):379-87. PubMed ID: 15246296
[TBL] [Abstract][Full Text] [Related]
12. Rough titanium alloys regulate osteoblast production of angiogenic factors.
Olivares-Navarrete R; Hyzy SL; Gittens RA; Schneider JM; Haithcock DA; Ullrich PF; Slosar PJ; Schwartz Z; Boyan BD
Spine J; 2013 Nov; 13(11):1563-70. PubMed ID: 23684238
[TBL] [Abstract][Full Text] [Related]
13. Corrosion, surface, and tribological behavior of electrophoretically deposited polyether ether ketone coatings on 316L stainless steel for orthopedic applications.
Ahmad K; Batool SA; Farooq MT; Minhas B; Manzur J; Yasir M; Wadood A; Avcu E; Ur Rehman MA
J Mech Behav Biomed Mater; 2023 Dec; 148():106188. PubMed ID: 37856992
[TBL] [Abstract][Full Text] [Related]
14. Assessment of a polyelectrolyte multilayer film coating loaded with BMP-2 on titanium and PEEK implants in the rabbit femoral condyle.
Guillot R; Pignot-Paintrand I; Lavaud J; Decambron A; Bourgeois E; Josserand V; Logeart-Avramoglou D; Viguier E; Picart C
Acta Biomater; 2016 May; 36():310-22. PubMed ID: 26965394
[TBL] [Abstract][Full Text] [Related]
15. Biomechanical and bioactivity concepts of polyetheretherketone composites for use in orthopedic implants-a review.
Abdullah MR; Goharian A; Abdul Kadir MR; Wahit MU
J Biomed Mater Res A; 2015 Nov; 103(11):3689-702. PubMed ID: 25856801
[TBL] [Abstract][Full Text] [Related]
16. Metallic biomaterials TiN-coated: corrosion analysis and biocompatibility.
Paschoal AL; Vanâncio EC; Canale Lde C; da Silva OL; Huerta-Vilca D; Motheo Ade J
Artif Organs; 2003 May; 27(5):461-4. PubMed ID: 12752209
[TBL] [Abstract][Full Text] [Related]
17. Spark plasma sintering synthesis of porous nanocrystalline titanium alloys for biomedical applications.
Nicula R; Lüthen F; Stir M; Nebe B; Burkel E
Biomol Eng; 2007 Nov; 24(5):564-7. PubMed ID: 17869173
[TBL] [Abstract][Full Text] [Related]
18. Biofilm formation on polyetheretherketone and titanium surfaces.
Barkarmo S; Longhorn D; Leer K; Johansson CB; Stenport V; Franco-Tabares S; Kuehne SA; Sammons R
Clin Exp Dent Res; 2019 Aug; 5(4):427-437. PubMed ID: 31452954
[TBL] [Abstract][Full Text] [Related]
19. Enhanced bioactivity of titanium-coated polyetheretherketone implants created by a high-temperature 3D printing process.
Jung HD; Jang TS; Lee JE; Park SJ; Son Y; Park SH
Biofabrication; 2019 Aug; 11(4):045014. PubMed ID: 31365916
[TBL] [Abstract][Full Text] [Related]
20. Reinforcement of polyetheretherketone polymer with titanium for improved mechanical properties and in vitro biocompatibility.
Jung HD; Park HS; Kang MH; Li Y; Kim HE; Koh YH; Estrin Y
J Biomed Mater Res B Appl Biomater; 2016 Jan; 104(1):141-8. PubMed ID: 25677541
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]