BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 36935387)

  • 1. Learning curve of fiberoptic bronchoscope-guided tracheal intubation through supraglottic airway device for pediatric airway management: a manikin study.
    Ji SH; Cho SA; Jang YE; Kim EH; Kim JT; Kim HS; Lee JH
    Korean J Anesthesiol; 2023 Aug; 76(4):290-299. PubMed ID: 36935387
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Learning curve for flexible bronchoscope-guided orotracheal intubation for anesthesiology residents: A cumulative sum analysis.
    Cai X; Yue M; Liu X; Zhang L; Wu S; Shen W; Yu A
    PLoS One; 2023; 18(7):e0288617. PubMed ID: 37440528
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Awake supraglottic airway guided flexible bronchoscopic intubation in patients with anticipated difficult airways: a case series and narrative review.
    Lim WY; Wong P
    Korean J Anesthesiol; 2019 Dec; 72(6):548-557. PubMed ID: 31475506
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Distance from the laryngeal mask grip to endotracheal tube tip. A crucial point during fiberoptic intubation in children].
    Mauch J; Haas T; Weiss M
    Anaesthesist; 2012 Feb; 61(2):123-8. PubMed ID: 22354398
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Air-Q
    Portas M; Canal MI; Barrio M; Alonso M; Cabrerizo P; López-Gil M; Zaballos M
    Rev Esp Anestesiol Reanim (Engl Ed); 2018 Mar; 65(3):135-142. PubMed ID: 29217156
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fiberoptic-guided tracheal tube placement through the air-Q® Intubating Laryngeal Airway: a performance study in a manikin.
    Galgon RE; Schroeder KM; Schmidt CS; Matioc AA; Han S; Andrei AC; Joffe AM
    J Anesth; 2011 Oct; 25(5):721-6. PubMed ID: 21796508
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A randomized multi-institutional crossover comparison of the GlideScope® Cobalt Video laryngoscope to the flexible fiberoptic bronchoscope in a Pierre Robin manikin.
    Fiadjoe JE; Hirschfeld M; Wu S; Markley J; Gurnaney H; Jawad AF; Stricker P; Kilbaugh T; Ross P; Kovatsis P
    Paediatr Anaesth; 2015 Aug; 25(8):801-806. PubMed ID: 25917552
    [TBL] [Abstract][Full Text] [Related]  

  • 8. I-gel Versus LMA-Fastrach Supraglottic Airway for Flexible Bronchoscope-Guided Tracheal Intubation Using a Parker (GlideRite) Endotracheal Tube: A Randomized Controlled Trial.
    Moore A; Gregoire-Bertrand F; Massicotte N; Gauthier A; Lallo A; Ruel M; Todorov A; Girard F
    Anesth Analg; 2015 Aug; 121(2):430-6. PubMed ID: 26076387
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Conversion of I-gel to definitive airway in a cervical immobilized manikin: Aintree intubation catheter vs long endotracheal tube.
    Chae YJ; Lee H; Jun B; Yi IK
    BMC Anesthesiol; 2020 Jun; 20(1):152. PubMed ID: 32552828
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fiberoptic-guided intubation after insertion of the i-gel airway device in spontaneously breathing patients with difficult airway predicted: a prospective observational study.
    Arévalo-Ludeña J; Arcas-Bellas JJ; Alvarez-Rementería R; Alameda LE
    J Clin Anesth; 2016 Dec; 35():287-292. PubMed ID: 27871545
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Is the Ambu aScope 3 Slim single-use fiberscope equally efficient compared with a conventional bronchoscope for management of the difficult airway?
    Fukada T; Tsuchiya Y; Iwakiri H; Ozaki M
    J Clin Anesth; 2016 May; 30():68-73. PubMed ID: 27041269
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fiberoptic-Guided and Blind Tracheal Intubation Through iLTS-D, Ambu® Auragain™, and I-Gel® Supraglottic Airway Devices: A Randomized Crossover Manikin Trial.
    Somri M; Matter I; Gaitini LA; Safadi A; Hawash N; Gómez-Ríos MÁ
    J Emerg Med; 2020 Jan; 58(1):25-33. PubMed ID: 31744705
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices.
    Jackson KM; Cook TM
    Anaesthesia; 2007 Apr; 62(4):388-93. PubMed ID: 17381577
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of i-gel, LMA-supreme, LMA-classic and LMAproseal as conduits of endotracheal intubation in newborns and infants: A manikin study.
    Ankay-Yılbaş A; Başaran B; Üzümcügil F; Akça B; İzgi M; Canbay Ö
    Turk J Pediatr; 2019; 61(2):166-173. PubMed ID: 32077644
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Continuous ventilation during intubation through a supraglottic airway device guided by fiberoptic bronchoscopy: a observational assessment.
    Landsdalen HE; Berge M; Kristensen F; Guttormsen AB; Søfteland E
    Acta Anaesthesiol Scand; 2017 Jan; 61(1):23-30. PubMed ID: 27808401
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of blind intubation with different supraglottic airway devices by inexperienced physicians in several airway scenarios: a manikin study.
    Bielski A; Smereka J; Madziala M; Golik D; Szarpak L
    Eur J Pediatr; 2019 Jun; 178(6):871-882. PubMed ID: 30903306
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The novel video-assisted intubating laryngeal mask Totaltrack compared to the intubating laryngeal mask Fastrach - a controlled randomized manikin study.
    Ott T; Barth A; Kriege M; Jahn-Eimermacher A; Piepho T; Noppens RR
    Acta Anaesthesiol Scand; 2017 Apr; 61(4):381-389. PubMed ID: 28251605
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A comparison of a fiberoptic stylet and a bougie as adjuncts to direct laryngoscopy in a manikin-simulated difficult airway.
    Kovacs G; Law JA; McCrossin C; Vu M; Leblanc D; Gao J
    Ann Emerg Med; 2007 Dec; 50(6):676-85. PubMed ID: 17681639
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clinical evaluation of Ambu
    Rangaswamy TM; Bharadwaj A; Jain P
    Int J Crit Illn Inj Sci; 2019; 9(4):157-163. PubMed ID: 31879601
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Efficacy of the Airtraq(®) laryngoscope with a fiberoptic bronchoscope compared with that of Airtraq(®) alone for tracheal intubation: a manikin study.
    Nishikawa K; Hukuoka E; Kawagishi T; Shimodate Y; Yamakage M
    J Anesth; 2011 Feb; 25(1):93-7. PubMed ID: 21052737
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.