These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
301 related articles for article (PubMed ID: 36949409)
21. A biomechanical study of standard posterior pelvic ring fixation versus a posterior pedicle screw construct. Vigdorchik JM; Jin X; Sethi A; Herzog DT; Oliphant BW; Yang KH; Vaidya R Injury; 2015 Aug; 46(8):1491-6. PubMed ID: 25986670 [TBL] [Abstract][Full Text] [Related]
22. Comparison of stability of two kinds of sacro-iliac screws in the fixation of bilateral sacral fractures in a finite element model. Zhao Y; Li J; Wang D; Liu Y; Tan J; Zhang S Injury; 2012 Apr; 43(4):490-4. PubMed ID: 22281196 [TBL] [Abstract][Full Text] [Related]
24. Do Transsacral-transiliac Screws Across Uninjured Sacroiliac Joints Affect Pain and Functional Outcomes in Trauma Patients? Heydemann J; Hartline B; Gibson ME; Ambrose CG; Munz JW; Galpin M; Achor TS; Gary JL Clin Orthop Relat Res; 2016 Jun; 474(6):1417-21. PubMed ID: 26472585 [TBL] [Abstract][Full Text] [Related]
25. Biomechanical Comparison of Tension Band Fixation of Patella Transverse Fracture: Headless Screws Versus Headed Screws. Martin JM; Applin DT; McGrady LM; Wang M; Schmeling GJ J Orthop Trauma; 2019 Jun; 33(6):e240-e245. PubMed ID: 30720558 [TBL] [Abstract][Full Text] [Related]
26. CT-guided sacroiliac percutaneous screw placement in unstable posterior pelvic ring injuries: accuracy of screw position, injury reduction and complications in 71 patients with 136 screws. Pieske O; Landersdorfer C; Trumm C; Greiner A; Wallmichrath J; Gottschalk O; Rubenbauer B Injury; 2015 Feb; 46(2):333-9. PubMed ID: 25487831 [TBL] [Abstract][Full Text] [Related]
27. Biomechanical investigation of four different fixation techniques in sacrum Denis type II fracture with low bone mineral density. Acklin YP; Zderic I; Richards RG; Schmitz P; Gueorguiev B; Grechenig S J Orthop Res; 2018 Jun; 36(6):1624-1629. PubMed ID: 29106756 [TBL] [Abstract][Full Text] [Related]
28. Analysis of trans-sacral corridors in stabilization of fractures of the pelvic ring. Jäckle K; Paulisch M; Blüchel T; Meier MP; Seitz MT; Acharya MR; Lehmann W; Spering C J Orthop Res; 2022 May; 40(5):1194-1202. PubMed ID: 34292624 [TBL] [Abstract][Full Text] [Related]
29. Sacroiliac versus transiliac-transsacral screw osteosynthesis in osteoporotic pelvic fractures: a biomechanical comparison. Cintean R; Fritzsche C; Zderic I; Gueorguiev-Rüegg B; Gebhard F; Schütze K Eur J Trauma Emerg Surg; 2023 Dec; 49(6):2553-2560. PubMed ID: 37535095 [TBL] [Abstract][Full Text] [Related]
30. Cement Augmentation in Sacroiliac Screw Fixation Offers Modest Biomechanical Advantages in a Cadaver Model. Osterhoff G; Dodd AE; Unno F; Wong A; Amiri S; Lefaivre KA; Guy P Clin Orthop Relat Res; 2016 Nov; 474(11):2522-2530. PubMed ID: 27334321 [TBL] [Abstract][Full Text] [Related]
31. Supplemental S1 fixation for type C pelvic ring injuries: biomechanical study of a long iliosacral versus a transsacral screw. Salari P; Moed BR; Bledsoe JG J Orthop Traumatol; 2015 Dec; 16(4):293-300. PubMed ID: 26026285 [TBL] [Abstract][Full Text] [Related]
32. [Finite element analysis of five internal fixation modes in treatment of Day type Pei X; Huang J; Qian S; Zhou W; Ke X; Wang G; Lei J; Liu X Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2023 Oct; 37(10):1205-1213. PubMed ID: 37848314 [TBL] [Abstract][Full Text] [Related]
33. Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring. Lodde MF; Katthagen JC; Schopper CO; Zderic I; Richards G; Gueorguiev B; Raschke MJ; Hartensuer R J Clin Med; 2021 May; 10(11):. PubMed ID: 34073570 [TBL] [Abstract][Full Text] [Related]
34. Biomechanical evaluation of a second generation headless compression screw for ankle arthrodesis in a cadaver model. Somberg AM; Whiteside WK; Nilssen E; Murawski D; Liu W Foot Ankle Surg; 2016 Mar; 22(1):50-4. PubMed ID: 26869501 [TBL] [Abstract][Full Text] [Related]
35. Anatomical conditions and patient-specific locked navigation templates for transverse sacroiliac screw placement: a retrospective study. Wu C; Deng J; Pan J; Li T; Tan L; Yuan D J Orthop Surg Res; 2020 Jul; 15(1):260. PubMed ID: 32660513 [TBL] [Abstract][Full Text] [Related]
36. Biomechanical Analysis of Conventional Partially Threaded Screws Versus Headless Compression Screws in Proximal Fifth Metatarsal (Jones) Fracture Fixation. Lam K; Bui R; Morris R; Panchbhavi V Foot Ankle Spec; 2021 Dec; 14(6):509-514. PubMed ID: 32506962 [TBL] [Abstract][Full Text] [Related]
37. Biomechanical properties of a posterior fully threaded positioning screw for cannulated screw fixation of displaced neck of femur fractures. Schaefer TK; Spross C; Stoffel KK; Yates PJ Injury; 2015 Nov; 46(11):2130-3. PubMed ID: 26342555 [TBL] [Abstract][Full Text] [Related]
38. Posterior pelvic ring bone density with implications for percutaneous screw fixation. Eastman JG; Shelton TJ; Routt MLC; Adams MR Eur J Orthop Surg Traumatol; 2021 Feb; 31(2):383-389. PubMed ID: 32902718 [TBL] [Abstract][Full Text] [Related]
39. Biomechanical comparison of augmented versus non-augmented sacroiliac screws in a novel hemi-pelvis test model. Grüneweller N; Raschke MJ; Zderic I; Widmer D; Wähnert D; Gueorguiev B; Richards RG; Fuchs T; Windolf M J Orthop Res; 2017 Jul; 35(7):1485-1493. PubMed ID: 27564231 [TBL] [Abstract][Full Text] [Related]
40. Mechanical comparison between lengthened and short sacroiliac screws in sacral fracture fixation: a finite element analysis. Zhao Y; Zhang S; Sun T; Wang D; Lian W; Tan J; Zou D; Zhao Y Orthop Traumatol Surg Res; 2013 Sep; 99(5):601-6. PubMed ID: 23850128 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]