These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
194 related articles for article (PubMed ID: 3695434)
1. A self-heated thermistor technique to measure effective thermal properties from the tissue surface. Patel PA; Valvano JW; Pearce JA; Prahl SA; Denham CR J Biomech Eng; 1987 Nov; 109(4):330-5. PubMed ID: 3695434 [TBL] [Abstract][Full Text] [Related]
2. Measurement of thermal conductivity, thermal diffusivity, and perfusion. Yuan DY; Valvano JW; Anderson GT Biomed Sci Instrum; 1993; 29():435-42. PubMed ID: 8329624 [TBL] [Abstract][Full Text] [Related]
3. Measurement of directional thermal properties of biomaterials. Bhavaraju NC; Cao H; Yuan DY; Valvano JW; Webster JG IEEE Trans Biomed Eng; 2001 Feb; 48(2):261-7. PubMed ID: 11296882 [TBL] [Abstract][Full Text] [Related]
4. The simultaneous measurement of thermal conductivity, thermal diffusivity, and perfusion in small volumes of tissue. Valvano JW; Allen JT; Bowman HF J Biomech Eng; 1984 Aug; 106(3):192-7. PubMed ID: 6492763 [TBL] [Abstract][Full Text] [Related]
5. Self-heated thermistor measurements of perfusion. Anderson GT; Valvano JW; Santos RR IEEE Trans Biomed Eng; 1992 Sep; 39(9):877-85. PubMed ID: 1473816 [TBL] [Abstract][Full Text] [Related]
6. Steady-state analysis of self-heated thermistors using finite elements. Hayes LJ; Valvano JW J Biomech Eng; 1985 Feb; 107(1):77-80. PubMed ID: 3981990 [TBL] [Abstract][Full Text] [Related]
7. [Effects of probe configuration on the measurement of bio-tissue thermal physical parameters using step-temperature technique]. Yang K; Liu W; Luo Q Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Oct; 24(5):1001-7. PubMed ID: 18027684 [TBL] [Abstract][Full Text] [Related]
8. Finite element analysis and experimental verification of multilayered tissue characterization using the thermal technique. Kharalkar NM; Valvano JW Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():3182-5. PubMed ID: 17946163 [TBL] [Abstract][Full Text] [Related]
9. Thermal diffusion probe and instrument system for tissue blood flow measurements: validation in phantoms and in vivo organs. Delhomme G; Newman WH; Roussel B; Jouvet M; Bowman HF; Dittmar A IEEE Trans Biomed Eng; 1994 Jul; 41(7):656-62. PubMed ID: 7927386 [TBL] [Abstract][Full Text] [Related]
10. Proposed methods for the measurement of regional renal blood flow using heat transfer analysis. Adams T; Spielman WS; Holmes KR; Heisey SR; Chen MM Ann Biomed Eng; 1985; 13(3-4):237-58. PubMed ID: 3898927 [TBL] [Abstract][Full Text] [Related]
11. A novel model of the pulse decay method for measurement of local tissue blood perfusion. Yang K; Liu W Med Eng Phys; 2004 Apr; 26(3):215-23. PubMed ID: 14984843 [TBL] [Abstract][Full Text] [Related]
12. Analysis of the Weinbaum-Jiji model of blood flow in the canine kidney cortex for self-heated thermistors. Valvano JW; Nho S; Anderson GT J Biomech Eng; 1994 May; 116(2):201-7. PubMed ID: 8078327 [TBL] [Abstract][Full Text] [Related]
13. An instrument for measuring endometrial blood flow in the uterus, using two thermistor probes. Hansson GA; Hauksson A; Strömberg P; Akerlund M J Med Eng Technol; 1987; 11(1):17-22. PubMed ID: 3585951 [TBL] [Abstract][Full Text] [Related]
14. Theory on thermal probe arrays for the distinction between the convective and the perfusive modalities of heat transfer in living tissues. Arkin H; Holmes KR; Chen MM J Biomech Eng; 1987 Nov; 109(4):346-52. PubMed ID: 3695437 [TBL] [Abstract][Full Text] [Related]
15. A thermal method for the determination of tissue blood flow. McCaffrey TV; McCook RD J Appl Physiol; 1975 Jul; 39(1):170-3. PubMed ID: 125256 [TBL] [Abstract][Full Text] [Related]
16. Measurements of effective thermal conductivity during hyperthermia: a comparison of experimental and clinical results. Delannoy J; Giaux G; Dittmar A; Newman WH; Delhomme G; Delvalee D Int J Hyperthermia; 1990; 6(1):143-54. PubMed ID: 2299227 [TBL] [Abstract][Full Text] [Related]
17. A sensitivity analysis of the step-temperature technique for measurement of local tissue blood perfusion. Yang K; Liu W J Med Eng Technol; 2008; 32(1):73-82. PubMed ID: 18183522 [TBL] [Abstract][Full Text] [Related]
18. A spherical source model for the thermal pulse decay method of measuring blood perfusion: a sensitivity analysis. Diederich CJ; Clegg S; Roemer RB J Biomech Eng; 1989 Feb; 111(1):55-61. PubMed ID: 2747234 [TBL] [Abstract][Full Text] [Related]
19. A small artery heat transfer model for self-heated thermistor measurements of perfusion in the kidney cortex. Anderson GT; Valvano JW J Biomech Eng; 1994 Feb; 116(1):71-8. PubMed ID: 8189717 [TBL] [Abstract][Full Text] [Related]
20. Micromachined hot-wire thermal conductivity probe for biomedical applications. Yi M; Panchawagh HV; Podhajsky RJ; Mahajan RL IEEE Trans Biomed Eng; 2009 Oct; 56(10):2477-84. PubMed ID: 19403359 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]